Carbon Fibre Reinforced Polymers (CFRP) has found an increased application in strengthening of concrete structures. Mostly the CFRP is used as externally bonded reinforcement. However, prestressing ...
This paper presents an upgrading and monitoring of a Swedish concrete railway bridge. The methods used for the upgrading as well as for the monitoring are innovative and new. Carbon fibre tubes are inserted in holes in the bridge deck, drilled in the transverse direction of the slab at a location ca. 40 mm from the top. Carbon fibre NSMR bars are bonded in transverse grooves in the soffit of the slab. Both methods are intended to increase the transverse bending moment capacity of the troughs' bottom slab in the ultimate limit state. Monitoring is performed to verify the effectiveness of the strengthening and to understand the behaviour of the bridge. However, for obvious reasons, monitoring is only carried out in the SLS (service limit state). Even though only marginal effects of strengthening could be recorded in the SLS, both the strengthening and monitoring were considered successful at a cost of approximately 8% of the total cost of a new bridge replacement.
Unbonded carbon fiber-reinforced polymer (CFRP) offers promise for use in prestressing applications due to its minimal creep and relaxation, low weight and high resistance to degradation. This study highlights the potential of CFRP rods in external and unbonded prestressing applications. A series of experiments were conducted on seven beams prestressed with unbonded external CFRP tendons anchored using a newly developed anchorage and post-tensioning system. The experiments investigated the effects of varying the initial tendon depth, prestressing force, and the presence of a deviator. The experimental results were compared to those observed with analogous beams prestressed with steel tendons, predictions made using an analytical model adapted from the literature and common beam theory. Results showed that steel and CFRP tendons had very similar effects on the structural behavior of the strengthened beams. Minor differences were observed that could be attributed to the difference between the modulus of elasticity of the CFRP and the steel used in the tests. Reinforced concrete beams prestressed with external bonded CFRP tendons exhibited the expected increase in strength, stiffness, and failure load, as well as decreased ductility, relative to unstrengthened beams. Under the loads examined in this study, the bending of CFRP tendons due to beam deflection did not significantly affect the tendon’s performance. Although the models predicted the beams’ load-bearing behavior accurately, they were less effective at predicting the stress experienced by the tendons. The findings from this study contribute to a better understanding of structural behavior of reinforced concrete beams post tensioned with external unbonded CFRP tendons throughout the load scheme.
High tensile strength, good resistance to degradation and creep, low weight and, to some extent, the ability to change the modulus of elasticity are some of the advantages of using prestressed, unidirectional FRP (Fibre Reinforced Polymer) tendon systems. Bonded and non-bonded versions of these systems have been investigated over the last three decades with results showing that prestressing systems can be very efficient when the FRP properties are properly exploited. However, there are often concerns as to how to exploit those properties to the full and how to achieve reliable anchorage with such systems. This is especially important in external post-tensioned tendon systems, where the anchorage points are exposed to the full load throughout the life span of the structure. Consequently, there are large requirements related to the long-term capacity and fatigue resistance of such systems. Several anchorage systems for use with Aramid, Glass and Carbon FRP tendons have been proposed over the last two decades. Each system is usually tailored to a particular type of tendon. This paper presents a brief overview of bonded anchorage applications while the primary literature review discusses three methods of mechanical anchorage: spike, wedge and clamping. Some proposals for future research are suggested. In general, the systems investigated showed inconsistent results with a small difference between achieving either a successful or an unsuccessful anchorage. These inconsistencies seem to be due to the brittleness of the tendons, low strength perpendicular to the fibre direction and insufficient stress transfer in the anchorage/tendon interface. As a result, anchorage failure modes tend to be excessive principal stresses, local crushing and interfacial slippage (abrasive wear), all of which are difficult to predict.
High tensile strength, good resistance to degradation and creep, low weight and, to some extent, the ability to change the modulus of elasticity are some of the advantages of using prestressed, unidirectional FRP (Fibre Reinforced Polymer) tendon systems. Bonded and non-bonded versions of these systems have been investigated over the last three decades with results showing that prestressing systems can be very efficient when the FRP properties are properly exploited. However, there are often concerns as to how to exploit those properties to the full and how to achieve reliable anchorage with such systems. This is especially important in external post-tensioned tendon systems, where the anchorage points are exposed to the full load throughout the life span of the structure. Consequently, there are large requirements related to the long-term capacity and fatigue resistance of such systems. Several anchorage systems for use with Aramid, Glass and Carbon FRP tendons have been proposed over the last two decades. Each system is usually tailored to a particular type of tendon. This paper presents a brief overview of bonded anchorage applications while the primary literature review discusses three methods of mechanical anchorage: spike, wedge and clamping. Some proposals for future research are suggested. In general, the systems investigated showed inconsistent results with a small difference between achieving either a successful or an unsuccessful anchorage. These inconsistencies seem to be due to the brittleness of the tendons, low strength perpendicular to the fibre direction and insufficient stress transfer in the anchorage/tendon interface. As a result, anchorage failure modes tend to be excessive principal stresses, local crushing and interfacial slippage (abrasive wear), all of which are difficult to predict.
The introduction of Fibre Reinforced Polymers (FRP) to the civil engineering market in the late 1980s resulted in the emergence of a range of new tools for rehabilitating and strengthening concrete ...
A durable and very efficient external strengthening system is achieved if steel tendons for posttensioning applications can be replaced with carbon fiber-reinforced polymer (CFRP) tendons, and if reliable anchorage systems are developed. This paper presents a newly developed and simple-to-use, two-piece wedge anchorage for CFRP tendons with an integrated sleeve and a differential angle between barrel and wedge sections. Three longitudinal slits are cut into the one-piece wedge, with one slit open and the other two stopping 1 mm from the inner wedge hole. The integrated sleeve holds the wedge's sections together during presetting and loading, resulting in a circumferential confined gripping of the CFRP tendon and optimized surface friction area. Therefore, the one-piece wedge differs from conventional wedge systems, where the wedges act separately with adjacent spaces, wedging the separate tendon sleeve in the longitudinal direction. Evaluation of the failure modes during testing was one of the main keys in achieving an increasingly better performance of the anchorage until the final anchorage was developed. The obtained failure modes are therefore described to enlighten the importance of addressing them when testing. The test setup used and measured behavior are described further together with the loading procedure. The anchorage reached the full capacity of the CFRP tendon and was seen to ensure a stable load of fracture.
Conical wedge anchorages are frequently used to anchor steel tendons in prestressing applications within the construction industry. To replace the steel tendons with non-corrosive and low weight FRPs (Fiber Reinforced Polymers), the different mechanical interactions between the steel and FRPs call for further development of the anchorage. In this paper, we derive and examine an analytical model for the internal stresses and strains within the anchorage for a prescribed presetting distance. This model is derived from the theory of thick walled cylinders under the assumptions regarding plane stress and axial symmetry. We simplify the resulting system of ten nonlinear equations and derive a method for solving them numerically. A comparison of plotted results for three different angles on the wedge's outer surface and six different presetting distances follows. These results are also compared to both axi-symmetric and 3D FE (Finite Element) models. Analytical and FE axi-symmetric models show good correspondence, though compared to the 3D FE model, they show a clear difference in the predicted radial stress distribution on the FRP. Thus, the derived analytical model can be a useful and fasteralternative to FE modeling of axi-symmetric anchorages. However, the model is of more restricted value and should be complemented by, for example, 3D FE models for other designs.
The tensioning of carbon-fiber-reinforced polymer (CFRP) rods for prestressed concrete applications or posttensioning repair and strengthening has been met with mixed success. This is primarily because of limitations inherent in the use of traditional wedge anchors typically used for steel tendons. Recently, an integrated sleeve-wedge anchorage has been successfully developed specifically for CFRP rods. This paper presents a numerical simulation of the newly developed anchorage by using ABAQUS. The three-dimensional (3D) finite-element (FE) model, which considers material nonlinearity, uses hexagonal elements for the barrel, CFRP rod, and tetrahedral elements for the integrated sleeve wedge. The simulated barrel surface strains are shown to compare well with optically measured strains; however, the numerical results are shown to be sensitive to the mechanical properties of the anchorage and CFRP rod and especially the transverse elastic modulus of the CFRP rod. Finally, the simulated strain distributions throughout the anchorage as well as the distribution of CFRP rod confining pressure are presented. Such strain and pressure distributions enable insights into the inner workings of the anchorage to be achieved. DOI: 10.1061/(ASCE)CC.1943-5614.0000171. (C) 2011 American Society of Civil Engineers.
Conical wedge anchorages are frequently used to anchor steel tendons in prestressing applications within the construction industry. To replace the steel tendons with non-corrosive and low weight FRPs (Fiber Reinforced Polymers), the different mechanical interactions between the steel and FRPs call for further development of the anchorage.In this paper, we derive and examine an analytical model for the internal stresses and strains within the anchorage for a prescribed presetting distance. This model is derived from the theory of thick walled cylinders under the assumptions regarding plane stress and axial symmetry. We simplify the resulting system of ten nonlinear equations and derive a method for solving them numerically. A comparison of plotted results for three different angles on the wedge's outer surface and six different presetting distances follows.These results are also compared to both axi-symmetric and 3D FE (Finite Element) models. Analytical and FE axi-symmetric models show good correspondence, though compared to the 3D FE model, they show a clear difference in the predicted radial stress distribution on the FRP. Thus, the derived analytical model can be a useful and faster alternative to FE modeling of axi-symmetric anchorages. However, the model is of more restricted value and should be complemented by, for example, 3D FE models for other designs.
Foreliggande rapport ar resultatet av laboratorieforsok vilka utforts pa avdelningen for byggkonstruktion vid Lulea tekniska universitet. Forsoken har genomforts under slutet av 2007 och ar en dire ...
The Swedish Railway administration has launched several projects aimed at increasing the accessibility of the railway lines in northern Sweden to meet future demands. One of these lines connects th ...
The Vindel Railway Bridge in northern Sweden is composed of a concrete deck, columns and an arch with a span of 110 m and a height of 22 m. In order to check the possibility to increase the axle load from 225 kN to 250 kN, the properties of the bridge needed to be evaluated. Especially, the dynamic behavior of the bridge is an important factor as it is affecting the load bearing capacity and the serviceability. In this paper, two types of three-dimensional (3-D) finite element models have been developed. One uses shell elements and the other uses beam elements. Based on the 3-D FE models, the effects of nonstructural mass, side spans and connection between columns and deck on the dynamic behavior are discussed. Furthermore, field test data from passing through train are compared with the results calculated by the models. The numerical simulations of the dynamic response coincide reasonably well with the field test data. © 2006 Taylor & Francis Group.
Banverket (The Swedish Railway Administrator) wanted to increase the maximum allowed axle load from 225 to 250 kN along the Swedish main northern railway line. One of the bridges, Bridge over The V ...