Aligning hand-held objects into mid-air positions and orientations is important for many applications. Task performance depends on speed and accuracy, and also on minimizing the user's physical exertion. Augmented reality head-mounted displays (AR HMDs) can guide users during mid-air alignments by tracking an object's pose and delivering visual instruction directly into the user's field of view (FoV). However, it is unclear which AR HMD interfaces are most effective for mid-air alignment guidance, and how the form factor of current AR HMD hardware (such as heaviness and low FoV) affects how users put themselves into tiring body poses during mid-air alignment. We defined a set of design requirements for mid-air alignment interfaces that target reduction of high-exertion body poses during alignment. We then designed, implemented, and tested several interfaces in a user study in which novice participants performed a sequence of mid-air alignments using each interface.Results show that interfaces that rely on visual guidance located near the hand-held object reduce acquisition times and translation errors, while interfaces that involve aiming at a faraway virtual object reduce rotation errors. Users tend to avoid focus shifts and to position the head and arms to maximize how much AR visualization is contained within a single FoV without moving the head. We found that changing the size of visual elements affected how far out the user extends the arm, which affects torque forces. We also found that dynamically adjusting where visual guidance is placed relative to the mid-air pose can help keep the head level during alignment, which is important for distributing the weight of the AR HMD.
BACKGROUND:The surgical workforce particularly in rural regions needs novel approaches to reinforce the skills and confidence of health practitioners. Although conventional telementoring systems have proven beneficial to address this gap, the benefits of platforms of augmented reality-based telementoring in the coaching and confidence of medical personnel are yet to be evaluated. METHODS:A total of 20 participants were guided by remote expert surgeons to perform leg fasciotomies on cadavers under one of two conditions: (1) telementoring (with our System for Telementoring with Augmented Reality) or (2) independently reviewing the procedure beforehand. Using the Individual Performance Score and the Weighted Individual Performance Score, two on-site, expert surgeons evaluated the participants. Postexperiment metrics included number of errors, procedure completion time, and self-reported confidence scores. A total of six objective measurements were obtained to describe the self-reported confidence scores and the overall quality of the coaching. Additional analyses were performed based on the participants' expertise level. RESULTS:Participants using the System for Telementoring with Augmented Reality received 10% greater Weighted Individual Performance Score (P = .03) and performed 67% fewer errors (P = .04). Moreover, participants with lower surgical expertise that used the System for Telementoring with Augmented Reality received 17% greater Individual Performance Score (P = .04), 32% greater Weighted Individual Performance Score (P < .01) and performed 92% fewer errors (P < .001). In addition, participants using the System for Telementoring with Augmented Reality reported 25% more confidence in all evaluated aspects (P < .03). On average, participants using the System for Telementoring with Augmented Reality received augmented reality guidance 19 times on average and received guidance for 47% of their total task completion time. CONCLUSION:Participants using the System for Telementoring with Augmented Reality performed leg fasciotomies with fewer errors and received better performance scores. In addition, participants using the System for Telementoring with Augmented Reality reported being more confident when performing fasciotomies under telementoring. Augmented Reality Head-Mounted Display-based telementoring successfully provided confidence and coaching to medical personnel.
Telementoring platforms can help transfer surgical expertise remotely. However, most telementoring platforms are not designed to assist in austere, pre-hospital settings. This paper evaluates the system for telementoring with augmented reality (STAR), a portable and self-contained telementoring platform based on an augmented reality head-mounted display (ARHMD). The system is designed to assist in austere scenarios: a stabilized first-person view of the operating field is sent to a remote expert, who creates surgical instructions that a local first responder wearing the ARHMD can visualize as three-dimensional models projected onto the patient’s body. Our hypothesis evaluated whether remote guidance with STAR could lead to performing a surgical procedure better, as opposed to remote audio-only guidance. Remote expert surgeons guided first responders through training cricothyroidotomies in a simulated austere scenario, and on-site surgeons evaluated the participants using standardized evaluation tools. The evaluation comprehended completion time and technique performance of specific cricothyroidotomy steps. The analyses were also performed considering the participants’ years of experience as first responders, and their experience performing cricothyroidotomies. A linear mixed model analysis showed that using STAR was associated with higher procedural and non-procedural scores, and overall better performance. Additionally, a binary logistic regression analysis showed that using STAR was associated to safer and more successful executions of cricothyroidotomies. This work demonstrates that remote mentors can use STAR to provide first responders with guidance and surgical knowledge, and represents a first step towards the adoption of ARHMDs to convey clinical expertise remotely in austere scenarios.
Augmented Reality (AR) benefits telementoring by enhancing the communication between the mentee and the remote mentor with mentor authored graphical annotations that are directly integrated into the mentee's view of the workspace. An important problem is conveying the workspace to the mentor effectively, such that they can provide adequate guidance. AR headsets now incorporate a frontfacing video camera, which can be used to acquire the workspace. However, simply providing to the mentor this video acquired from the mentee's first-person view is inadequate. As the mentee moves their head, the mentor's visualization of the workspace changes frequently, unexpectedly, and substantially. This paper presents a method for robust high-level stabilization of a mentee first-person video to provide effective workspace visualization to a remote mentor. The visualization is stable, complete, up to date, continuous, distortion free, and rendered from the mentee's typical viewpoint, as needed to best inform the mentor of the current state of the workspace. In one study, the stabilized visualization had significant advantages over unstabilized visualization, in the context of three number matching tasks. In a second study, stabilization showed good results, in the context of surgical telementoring, specifically for cricothyroidotomy training in austere settings.
Introduction Surgical telementoring connects expert mentors with trainees performing urgent care in austere environments. However, such environments impose unreliable network quality, with significant latency and low bandwidth. We have developed an augmented reality telementoring system that includes future step visualization of the medical procedure. Pregenerated video instructions of the procedure are dynamically overlaid onto the trainee's view of the operating field when the network connection with a mentor is unreliable. Methods Our future step visualization uses a tablet suspended above the patient's body, through which the trainee views the operating field. Before trainee use, an expert records a "future library" of step-by-step video footage of the operation. Videos are displayed to the trainee as semitransparent graphical overlays. We conducted a study where participants completed a cricothyroidotomy under telementored guidance. Participants used one of two telementoring conditions: conventional telestrator or our system with future step visualization. During the operation, the connection between trainee and mentor was bandwidth throttled. Recorded metrics were idle time ratio, recall error, and task performance. Results Participants in the future step visualization condition had 48% smaller idle time ratio (14.5% vs. 27.9%, P < 0.001), 26% less recall error (119 vs. 161, P = 0.042), and 10% higher task performance scores (rater 1 = 90.83 vs. 81.88, P = 0.008; rater 2 = 88.54 vs. 79.17, P = 0.042) than participants in the telestrator condition. Conclusions Future step visualization in surgical telementoring is an important fallback mechanism when trainee/mentor network connection is poor, and it is a key step towards semiautonomous and then completely mentor-free medical assistance systems.
This poster presents the design, implementation, and evaluation of a method for robust high-level stabilization of mentees first-person video in augmented reality (AR) telementoring. This video is captured by the front-facing built-in camera of an AR headset and stabilized by rendering from a stationary view a planar proxy of the workspace projectively texture mapped with the video feed. The result is stable, complete, up to date, continuous, distortion free, and rendered from the mentee's default viewpoint. The stabilization method was evaluated in two user studies, in the context of number matching and for cricothyroidotomy training, respectively. Both showed a significant advantage of our method compared with unstabilized visualization.
Photogrammetry is a popular method of 3D reconstruction that uses conventional photos as input. This method can achieve high quality reconstructions so long as the scene is densely acquired from multiple views with sufficient overlap between nearby images. However, it is challenging for a human operator to know during acquisition if sufficient coverage has been achieved. Insufficient coverage of the scene can result in holes, missing regions, or even a complete failure of reconstruction. These errors require manually repairing the model or returning to the scene to acquire additional views, which is time-consuming and often infeasible. We present a novel approach to photogrammetric acquisition that uses an AR HMD to predict a set of covering views and to interactively guide an operator to capture imagery from each view. The operator wears an AR HMD and uses a handheld camera rig that is tracked relative to the AR HMD with a fiducial marker. The AR HMD tracks its pose relative to the environment and automatically generates a coarse geometric model of the scene, which our approach analyzes at runtime to generate a set of human-reachable acquisition views covering the scene with consistent camera-to-scene distance and image overlap. The generated view locations are rendered to the operator on the AR HMD. Interactive visual feedback informs the operator how to align the camera to assume each suggested pose. When the camera is in range, an image is automatically captured. In this way, a set of images suitable for 3D reconstruction can be captured in a matter of minutes. In a user study, participants who were novices at photogrammetry were tasked with acquiring a challenging and complex scene either without guidance or with our AR HMD based guidance. Participants using our guidance achieved improved reconstructions without cases of reconstruction failure as in the control condition. Our AR HMD based approach is self-contained, portable, and provides specific acquisition guidance tailored to the geometry of the scene being captured.
Objective: This study investigates the benefits of a surgical telementoring system based on an augmented reality head-mounted display (ARHMD) that overlays surgical instructions directly onto the surgeon's view of the operating field, without workspace obstruction. Summary Background Data: In conventional telestrator-based telementoring, the surgeon views annotations of the surgical field by shifting focus to a nearby monitor, which substantially increases cognitive load. As an alternative, tablets have been used between the surgeon and the patient to display instructions; however, tablets impose additional obstructions of surgeon's motions. Methods: Twenty medical students performed anatomical marking (Task1) and abdominal incision (Task2) on a patient simulator, in 1 of 2 telementoring conditions: ARHMD and telestrator. The dependent variables were placement error, number of focus shifts, and completion time. Furthermore, workspace efficiency was quantified as the number and duration of potential surgeontablet collisions avoided by the ARHMD. Results: The ARHMD condition yielded smaller placement errors (Task1: 45%, P < 0.001; Task2: 14%, P = 0.01), fewer focus shifts (Task1: 93%, P < 0.001; Task2: 88%, P = 0.0039), and longer completion times (Task1: 31%, P < 0.001; Task2: 24%, P = 0.013). Furthermore, the ARHMD avoided potential tablet collisions (4.8 for 3.2 seconds in Task1; 3.8 for 1.3 seconds in Task2). Conclusion: The ARHMD system promises to improve accuracy and to eliminate focus shifts in surgical telementoring. Because ARHMD participants were able to refine their execution of instructions, task completion time increased. Unlike a tablet system, the ARHMD does not require modifying natural motions to avoid collisions.
We present a system that enables a novice user to acquire a large indoor scene in minutes as a collection of images that are sufficient for five degrees-of-freedom virtual navigation by image morphing. The user walks through the scene wearing an augmented reality head-mounted display (AR HMD) enhanced with a panoramic video camera. The AR HMD visualizes a 2D grid partitioning of a dynamically generated floor plan, which guides the user to acquire a panorama from each grid cell. The panoramas are registered offline using both AR HMD tracking data and structure-from-motion tools. Feature correspondences are established between neighboring panoramas. The resulting panoramas and correspondences support interactive rendering via image morphing with any view direction and from any viewpoint on the acquisition plane.
This paper presents two positions about the use of augmented reality (AR) in healthcare scenarios, informed by the authors' experience as an interdisciplinary team of academics and medical practicioners who have been researching, implementing, and validating an AR surgical telementoring system. First, AR has the potential to greatly improve the areas of surgical telementoring and of medical training on patient simulators. In austere environments, surgical telementoring that connects surgeons with remote experts can be enhanced with the use of AR annotations visualized directly in the surgeon's field of view. Patient simulators can gain additional value for medical training by overlaying the current and future steps of procedures as AR imagery onto a physical simulator. Second, AR annotations for telementoring and for simulator-based training can be delivered either by video see-through tablet displays or by AR head-mounted displays (HMDs). The paper discusses the two AR approaches by looking at accuracy, depth perception, visualization continuity, visualization latency, and user encumbrance. Specific advantages and disadvantages to each approach mean that the choice of one display method or another must be carefully tailored to the healthcare application in which it is being used.
We present a system that enables a novice user to acquire a large indoor scene in minutes as a collection of images sufficient for five degrees-of-freedom virtual navigation by image morphing. The user walks through the scene wearing an augmented reality head-mounted display (AR HMD) enhanced with a panoramic video camera. The AR HMD shows a 2D grid of a dynamically generated floor plan, which guides the user to acquire a panorama from each grid cell. After acquisition, panoramas are preliminarily registered using the AR HMD tracking data, corresponding features are detected in pairs of neighboring panoramas, and the correspondences are used to refine panorama registration. The registered panoramas and their correspondences support rendering the scene interactively with any view direction and from any viewpoint on the acquisition plane. An HMD VR interface guides the user who optimizes visualization fidelity interactively, by aligning the viewpoint with one of the hundreds of acquisition locations evenly sampling the floor plane.
because of loss of stereopsis: binocular depth cues are not preserved Objective: This study investigates the benefits of a surgical telementoring system based on an augmented reality head-mounted display (ARHMD) that overlays surgical instructions directly onto the surgeon’s view of the operating field, without workspace obstruction. Summary Background Data: In conventional telestrator-based telementoring, the surgeon views annotations of the surgical field by shifting focus to a nearby monitor, which substantially increases cognitive load. As an alternative, tablets have been used between the surgeon and the patient to display instructions; however, tablets impose additional obstructions of surgeon’s motions. Methods: Twenty medical students performed anatomical marking (Task1) and abdominal incision (Task2) on a patient simulator, in 1 of 2 telementoring conditions: ARHMD and telestrator. The dependent variables were placement error, number of focus shifts, and completion time. Furthermore, workspace efficiency was quantified as the number and duration of potential surgeontablet collisions avoided by the ARHMD. Results: The ARHMD condition yielded smaller placement errors (Task1: 45%, P< 0.001; Task2: 14%, P1⁄4 0.01), fewer focus shifts (Task1: 93%, P< 0.001; Task2: 88%, P1⁄4 0.0039), and longer completion times (Task1: 31%, P < 0.001; Task2: 24%, P 1⁄4 0.013). Furthermore, the ARHMD avoided potential tablet collisions (4.8 for 3.2 seconds in Task1; 3.8 for 1.3 seconds in Task2). Conclusion: The ARHMD system promises to improve accuracy and to eliminate focus shifts in surgical telementoring. Because ARHMD participants were able to refine their execution of instructions, task completion time increased. Unlike a tablet system, the ARHMD does not require modifying natural motions to avoid collisions.
This application paper presents the work of a multidisciplinary group of designing, implementing, and testing an Augmented Reality (AR) surgical telementoring system. The system acquires the surgical field with an overhead camera, the video feed is transmitted to the remote mentor, where it is displayed on a touch-based interaction table, the mentor annotates the video feed, the annotations are sent back to the mentee, where they are displayed into the mentee's field of view using an optical see-through AR head-mounted display (HMD). The annotations are reprojected from the mentor's second-person view of the surgical field to the mentee's first-person view. The mentee sees the annotations with depth perception, and the annotations remain anchored to the surgical field as the mentee moves their head. Average annotation display accuracy is 1.22cm. The system was tested in the context of a user study where surgery residents ( $n = 20$ ) were asked to perform a lower-leg fasciotomy on cadaver models. Participants who benefited from telementoring using our system received a higher Individual Performance Score, and they reported higher usability and self confidence levels.
Hand-held transparent displays are important infrastructure for augmented reality applications. Truly transparent displays are not yet feasible in hand-held form, and a promising alternative is to simulate transparency by displaying the image the user would see if the display were not there. Previous simulated transparent displays have important limitations, such as being tethered to auxiliary workstations, requiring the user to wear obtrusive head-tracking devices, or lacking the depth acquisition support that is needed for an accurate transparency effect for close-range scenes.We describe a general simulated transparent display and three prototype implementations (P1, P2, and P3), which take advantage of emerging mobile devices and accessories. P1 uses an off-theshelf smartphone with built-in head-tracking support; P1 is compact and suitable for outdoor scenes, providing an accurate transparency effect for scene distances greater than 6m. P2 uses a tablet with a built-in depth camera; P2 is compact and suitable for short-distance indoor scenes, but the user has to hold the display in a fixed position. P3 uses a conventional tablet enhanced with on-board depth acquisition and head tracking accessories; P3 compensates for user head motion and provides accurate transparency even for closerange scenes. The prototypes are hand-held and self-contained, without the need of auxiliary workstations for computation.
Background The goal of this study was to design and implement a novel surgical telementoring system called the System for Telementoring with Augmented Reality (STAR) that uses a virtual transparent display to convey precise locations in the operating field to a trainee surgeon. This system was compared with a conventional system based on a telestrator for surgical instruction. Methods A telementoring system was developed and evaluated in a study which used a 1 × 2 between-subjects design with telementoring system, that is, STAR or conventional, as the independent variable. The participants in the study were 20 premedical or medical students who had no prior experience with telementoring. Each participant completed a task of port placement and a task of abdominal incision under telementoring using either the STAR or the conventional system. The metrics used to test performance when using the system were placement error, number of focus shifts, and time to task completion. Results When compared with the conventional system, participants using STAR completed the 2 tasks with less placement error (45% and 68%) and with fewer focus shifts (86% and 44%), but more slowly (19% for each task). Conclusions Using STAR resulted in decreased annotation placement error, fewer focus shifts, but greater times to task completion. STAR placed virtual annotations directly onto the trainee surgeon's field of view of the operating field by conveying location with great accuracy; this technology helped to avoid shifts in focus, decreased depth perception, and enabled fine-tuning execution of the task to match telementored instruction, but led to greater times to task completion.
Conventional surgical telementoring systems require the trainee to shift focus away from the operating field to a nearby monitor to receive mentor guidance. This paper presents the next generation of telementoring systems. Our system, STAR (System for Telementoring with Augmented Reality) avoids focus shifts by placing mentor annotations directly into the trainee's field of view using augmented reality transparent display technology. This prototype was tested with pre-medical and medical students. Experiments were conducted where participants were asked to identify precise operating field locations communicated to them using either STAR or a conventional telementoring system. STAR was shown to improve accuracy and to reduce focus shifts. The initial STAR prototype only provides an approximate transparent display effect, without visual continuity between the display and the surrounding area. The current version of our transparent display provides visual continuity by showing the geometry and color of the operating field from the trainee's viewpoint.
Existing telestrator-based surgical telementoring systems require a trainee surgeon to shift focus frequently between the operating field and a nearby monitor to acquire and apply instructions from a remote mentor. We present a novel approach to surgical telementoring where annotations are superimposed directly onto the surgical field using an augmented reality (AR) simulated transparent display. We present our first steps towards realizing this vision, using two networked conventional tablets to allow a mentor to remotely annotate the operating field as seen by a trainee. Annotations are anchored to the surgical field as the trainee tablet moves and as the surgical field deforms or becomes occluded. The system is built exclusively from compact commodity-level components--all imaging and processing are performed on the two tablets.