BACKGROUND:Remimazolam (CNS 7056) is a new ultra-short acting benzodiazepine for IV sedation. This study aimed to investigate the electroencephalogram (EEG) pharmacodynamics of remimazolam infusion.METHODS:Twenty healthy male volunteers received remimazolam as continuous IV infusion of 5 mg/min for 5 min, 3 mg/min for the next 15 min, and 1 mg/min for further 15 min. Continuous EEG monitoring was performed by a neurophysiologic system with electrodes placed at F3, F4, C3, C4, O1, O2, Cz, and Fp1 (10/20 system) and using the Narcotrend Index. Sedation was assessed clinically by using the Modified Observer's Assessment of Alertness and Sedation scale. Pharmacodynamic models were developed for selected EEG variables and Narcotrend Index.RESULTS:EEG changes during remimazolam infusion were characterized by an initial increase in beta frequency band and a late increase in delta frequency band. The EEG beta ratio showed a prediction probability of Modified Observer's Assessment of Alertness and Sedation score of 0.79, and could be modeled successfully using a standard sigmoid Emax model. Narcotrend Index showed a prediction probability of Modified Observer's Assessment of Alertness and Sedation score of 0.74. The time course of Narcotrend Index was described by an extended sigmoid Emax model with two sigmoid terms and different plasma-effect equilibration times.CONCLUSIONS:Beta ratio was identified as a suitable EEG variable for monitoring remimazolam sedation. Narcotrend Index appeared less suitable than the beta ratio for monitoring the sedative effect if remimazolam is administered alone.
Objective: Evaluate the accuracy and trending ability of the fourth-generation FloTrac/EV1000 (Edwards Lifesciences, Irvine, CA) system in patients with severe aortic valve stenosis by comparing FloTrac/EV1000-derived cardiac output (CCO-FT) with continuous thermodilution pulmonary artery catheter (CCO-PAC) measurements before and after surgical valve replacement. Design: Prospective clinical study. Setting: Anesthesia for cardiac surgery, operating room, single-center university hospital. Participants: Twenty-five patients were included. After exclusion, 20 patients undergoing elective aortic valve replacement were analyzed. Interventions: After induction of general anesthesia, CCO-FT and CCO-PAC values were recorded every 30 seconds before and after aortic valve replacement with a bioprosthesis under cardiopulmonary bypass (CPB). Measurements and Main Results: Data were analyzed separately from skin incision to last suture and before and after CPB. Regression analyses, Bland-Altman analyses, and trending analyses (4-quadrant plot, polar plot) were performed. The percentage errors of the FloTrac/EV1000 were 69.7% and 59.3% before and after CPB, respectively. The concordance rates (CRs) and angular CRs of the FloTrac/EV1000 were 50.9% and 57.1%, and 48.7% and 61.9% before and after CPB, respectively. Conclusion: This study revealed a low level of agreement and poor trending ability of the FloTrac/EV1000 system compared to continuous thermodilution pulmonary artery catheter in patients with severe aortic stenosis. Although there was a slight improvement after surgical valve replacement and CPB, the results were not within acceptable limits to replace CCO-PAC in this patient population. (C) 2018 Elsevier Inc. All rights reserved.
Purpose: Noninvasive cerebral optical spectrometry is a promising candidate technology for the objective assessment physiological changes during pain perception. This study's primary objective was to test if there was a significant correlation between the changes in physiological parameters as measured by a cerebral optical spectrometry-based algorithm (real-time objective pain assessment [ROPA]) and subjective pain ratings obtained from volunteers and laboring women. Secondary aims were performance assessment using linear regression and receiver operating curve (ROC) analysis. Patients and methods: Prospective cohort study performed in Human Pain Laboratory and Labor and Delivery Unit. After institutional review board approval, we evaluated ROPA in volunteers undergoing the cold pressor test and in laboring women before and after epidural or combined spinal epidural placement. Linear regression was performed to measure correlations. ROCs and corresponding areas under the ROCs (AUC), as well as Youden's indices, as a measure of diagnostic effectiveness, were calculated. Results: Correlations between numeric rating scale or visual analog scale and ROPA were significant for both volunteers and laboring women. AUCs for both volunteers and laboring women with numeric rating scale and visual analog scale subjective pain ratings as ground truth revealed at least good (AUC: 70%-79%) to excellent (AUC >90%) distinction between clinically meaningful pain severity differentiations (no/mild-moderate-severe). Conclusion: Cerebral Optical Spectrometry-based ROPA significantly correlated with subjectively reported pain in volunteers and laboring women, arid could be a useful monitor for clinical circumstances where direct assessment is not available, or to complement patient-reported pain scores.
Background: Wavelet transform based analysis of heart rate variability is increasingly being used for a wide variety of clinical applications. There is no gold standard as to which wavelet to use and the correlation between results obtained by using different wavelets is unknown. Methods: Heart rate variability in electrocardiograms from healthy volunteers was analyzed using the following wavelets (maximum overlap discrete wavelet packet transform): Haar, Daubechies 2, 4, and 8, least asymmetric Daubechies 4 and 8, and best localized Daubechies 7 using the RHRV package in R. Correlation of power in the different frequency bands (ultra low frequency (ULF), very low frequency (VLF), low frequency (LF), high frequency (HF)) as well as total power and LF:HF ratio were calculated. Bland-Altman comparisons were also made for selected wavelets to test for agreement. Findings: Correlations between results obtained by different wavelets were all statistically significant. Most correlation coefficients were moderate (0.3 <= r <= 0.7). They were, however, generally lower for the LF:HF ratio, which is commonly used to assess balance of the autonomic nervous system. Conclusion: It is necessary to report which wavelet is used when performing wavelet transform based heart rate variability analysis and depending on whether one is interested in detecting onset or intensity of changes performance of wavelets will vary. (C) 2017 Elsevier Ltd. All rights reserved.
Postincisional hyperalgesia and allodynia play an important role in perioperative medicine. NaV1.7 sodium channel has proven to be a key player in several pain states, including acute, inflammatory, and neuropathic pain. This study investigated the effects of silencing NaV1.7 through Herpes-based gene therapy with an antisense transcript on pain states after incision of the skin in rodents. Seventy-six Balb/C mice were subdivided into six groups and were treated with no virus, control virus, or NaV1.7 antisense vector before lateral hindpaw skin incision or sham procedure. All mice were tested for mechanical allodynia, cold allodynia, and thermal hyperalgesia. For time series analysis, a two-way analysis of variance with post-hoc Bonferroni testing was used. After incision mice developed significant hypersensitivity to mechanical, cold, and heat stimuli. The NaV1.7 antisense vector blocked the hypersensitivity to mechanical, cold, and heat stimuli that was normally observed 24 and 48 h after incision. We demonstrated that a gene therapy-based NaV1.7 knockdown affects postincisional hyperalgesia and allodynia. The data provide evidence that the incision model leads to periwound hypersensitivity after incision and that application of the NaV1.7 antisense virus prevents this sensitization. This then, in turn, provides presumptive support to the hypothesis that overexpression of the NaV1.7 channel is an important mechanism underlying hyperalgesia and allodynia following skin incision.
Inadvertent perioperative hypothermia (IPH) leads to surgical complications and increases length of stay. IPH rates are high with the current standard of care, forced air warming (FAW). Our hypothesis is that a prototype thermal compression device that heats the popliteal fossa and soles of the feet, with lower leg compression, increases perioperative temperatures and reduces IPH compared to the current standard of care.
Lysophosphatidic acid (LPA) is a bioactive lipid that impacts neurological outcomes after neurotrauma by inhibiting neuroregeneration, promoting inflammation, and contributing to behavioral deficits. Blocking LPA signaling with a novel anti-LPA monoclonal antibody (mAb) is neuroprotective after traumatic brain injury (TBI) if given to injured animals whose blood-brain barrier (BBB) has been compromised. It is hypothesized that the anti-LPA mAb could improve chronic pain initiated by TBI. However, poor brain penetration after systemic application of the antibody makes access to the central nervous system (CNS) problematic in situations where the BBB is intact. Our experiments investigated whether intranasal delivery of the anti-LPA mAb could bypass the BBB, allowing for direct entry of the antibody to certain areas of the CNS. When the humanized anti-LPA mAb, LT3114, was intranasally applied to injured rats within 30 minutes after mild TBI using the central lateral percussion model, enzyme-linked immunospecific assay and immunohistochemistry demonstrated antibody uptake to several areas in the CNS, including the area of cortical injury, the corpus callosum, cerebellum, and the subventricular region. Compared with control rats that received LT3114 but no TBI, TBI rats demonstrated significantly higher concentrations of intranasally administered LT3114 antibody in some tissues. In behavioral studies, a significant attenuation of mechanical allodynia after TBI was observed in the anti-LPA treatment group (P = 0.0079), when compared with vehicle controls within 14 days after TBI. These results suggest that intranasal application of the anti-LPA antibody directly accesses CNS sites involved in TBI-related pain and that this access attenuates pain sequelae to the neurotrauma.
Morphine is a widely-used opioid analgesic to treat post-operative pain in the intensive care unit. For the quantification of morphine and its metabolite Glucuronide (M6G) concentrations a sensitive and specific liquid chromatography–tandem mass spectrometry (LC-MS/MS) method was developed and validated according to Food and Drug Administration (FDA) guidelines. Plasma samples were extracted with solid-phase extraction and substituted with deuterated morphine and M6G as internal standards. Separation was performed by gradient elution using UPLC-like system and analyzed by MS/MS consisting of an electrospray ionization source. The lower limit of quantification was 500 ‘‘pg/ml’’ for morphine and 50 ‘‘pg/ml’’ for M6G. Intra- and interassay precision and accuracy did not exceed ± 15%. The method was applied to a clinical study during intensive care treatment of patients after coronary artery bypass grafting and can serve for further pharmacokinetic studies.
Approximately 1.7 million Americans sustain a traumatic brain injury (TBI) each year and chronic pain is a common complication.
For the quantification of propofol total and unbound drug concentrations a sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated. To separate unbound propofol an ultrafiltration step before sample preparation was performed. Both the ultrafiltrate and plasma samples were extracted with solid-phase extraction and substituted with deuterated propofol as an internal standard. Separation was performed by gradient elution using UPLC-like system and analyzed by MS/MS consisting of an electrospray ionization source. To detect low and high concentration levels of propofol two calibration curves were identified and showed linearity within the range of 1-50 ng/ml and 50-20000 ng/ml. The lower limit of quantification was 1 ng/ml. Intra- and interassay precision and accuracy did not exceed +/- 15%. The method was applied to a clinical study during intensive care treatment of patients after coronary artery bypass grafting. (C) 2016 Elsevier B.V. All rights reserved.
CEACAM20, a novel member of the CEACAM1 gene family with expression limited to the lumen of small intestine, testes, and prostate, is co-expressed with CEACAM1 in adult prostate tissue and down-regulated to the same extent as CEACAM1 in prostate cancer. Since prostate cancer often involves loss of epithelial lumen formation, we hypothesized that CEACAM20 and CEACAM1 play important roles in lumen formation of normal prostate epithelium. When prostate cells were grown on Matrigel as a source of extracellular matrix (ECM), they differentiated into acinar structures with single tubules and well-defined lumina closely resembling embryonic prostate organoids. Confocal microscopic analysis revealed restriction of CEACAM20 to acini and CEACAM1 to tubule structures, respectively. Inhibition of CEACAM1 with antibodies or soluble CEACAM1 or antisense oligonucleotides inhibited tubule formation by over 50% while the remaining tubules were stunted. Inhibition of CEACAM20 with antisense oligonucleotides completely inhibited tubule formation and stunted the growth of acini. We conclude that CEACAM20 and CEACAM1 not only mark the lumina of adult prostate tissue but also play a critical role in the vitro generation of prostate organoids.
The vertebrate-restricted carcinoembryonic antigen gene family evolves extremely rapidly. Among their widely expressed members, the mammal-specific, secreted CEACAM16 is exceptionally well conserved and specifically expressed in the inner ear. To elucidate a potential auditory function, we inactivated murine Ceacam16 by homologous recombination. In young Ceacam16(-/-) mice the hearing threshold for frequencies below 10 kHz and above 22 kHz was raised. This hearing impairment progressed with age. A similar phenotype is observed in hearing-impaired members of Family 1070 with non-syndromic autosomal dominant hearing loss (DFNA4) who carry a missense mutation in CEACAM16. CEACAM16 was found in interdental and Deiters cells and was deposited in the tectorial membrane of the cochlea between postnatal days 12 and 15, when hearing starts in mice. In cochlear sections of Ceacam16(-/-) mice tectorial membranes were significantly more often stretched out as compared with wild-type mice where they were mostly contracted and detached from the outer hair cells. Homotypic cell sorting observed after ectopic cell surface expression of the carboxyl-terminal immunoglobulin variable-like N2 domain of CEACAM16 indicated that CEACAM16 can interact in trans. Furthermore, Western blot analyses of CEACAM16 under reducing and non-reducing conditions demonstrated oligomerization via unpaired cysteines. Taken together, CEACAM16 can probably form higher order structures with other tectorial membrane proteins such as alpha-tectorin and beta-tectorin and influences the physical properties of the tectorial membrane. Evolution of CEACAM16 might have been an important step for the specialization of the mammalian cochlea, allowing hearing over an extended frequency range.
Instute of Immunology, Friedrich-Loeffler Institut, Greifswald-Insel Riems, Germany; Department of Otorhinolaryngology, University of Tübingen, Hearing Research Centre Tübingen, Tübingen, Germany; Tumor Immunology Laboratory, LIFE Center, University Clinic of Munich, Munich, Germany; Department of Otolaryngology, Osaka City University Medical School, Osaka, Japan; Experimental Urology, Department of Urology, University Clinic of Munich, Munich, Germany; 6 Aldevron Freiburg, Freiburg, Germany; 7 Institute of Medical Genetics CBF, Charité-University Medicine-Berlin, Berlin, Germany, and Max-Planck Institute for Molecular Genetics, Berlin, Germany; Institute of Molecular Animal Breeding and Biotechnology, Gene Center, University of Munich, Munich, Germany.
The carcinoembryonic antigen (CEA) family comprises a still actively evolving populous group of proteins that are involved in controlling tissue homeostasis, immune responses, and host/pathogen interactions. The genes identified to date in rodents and primates exhibit low sequence similarity and an extremely variable domain composition. Among the 22 murine Cea-related genes, only for Ceacam1 has an ortholog been assigned. To identify all CEA-related genes in mouse, rat, and human we undertook genome-wide analyses. Eight of 9 new expressible genes (Ceacam12-Ceacam20) could be located within the approximately 6.5-Mb murine Cea locus. Five of the genes were rodent-specific (Ceacam12-Ceacam15 and Ceacam17). Surprisingly, for the remaining 4 (Ceacam16 and Ceacam18-Ceacam20) orthologs could be detected in all three genomes at syntenic locations. Gene-specific reverse transcription/PCR analyses of total RNA from 31 murine adult, placental, and embryonic tissues as well as tumors revealed very distinct expression patterns, suggesting diversified functions within the CEA family.