Controlled local delivery of therapeutics (small molecule drug crystals or biologics) for knee-associated diseases such as osteoarthritis necessitates patient compliance, ensuring that the injected depot does not trigger local tissue inflammation and immune responses. A local drug delivery strategy that releases drug at a controlled rate while ensuring minimal tolerability issues at the injection site would be an appealing paradigm in intra-articular (IA) therapies. Herein, we report the formulation development and characterization of surface modified PLGA microparticles (MPs) through the surface integration of a cationic lipid, DOTAP (1,2-Dioleoyl-3-trimethylammonium propane). Following IA administration, these particles are able to interact with anionic synovial fluid glycosaminoglycans (GAGs) to form an in-situ surface coating in the knee joint, thereby reducing the depot-associated local inflammatory response. The formulated microparticles were about 10-40 µm in size range, with a +19 to +33 mV overall surface charge after DOTAP lipid surface integration. These particles showed preferential surface adhesion with endogenous anionic GAGs (e.g., hyaluronic acid) due to electrostatic interactions in vitro, and approximately 65% of the model drug triamcinolone acetonide (TCA) was released after 10 weeks in simulated synovial fluid. The uncoated and DOTAP-coated PLGA microparticles had no effect on mouse osteoblast MC3T3 cell viability and human macrophage inflammatory response. Further, DOTAP-coated particles showed a marginal decrease in pro-inflammatory cytokines in naïve rats following knee injection. Together, the results suggest that surface-modified PLGA particles may have promising potential as delivery carriers for long-acting injectables.
Long-acting injectable (LAI) delivery technologies have enabled the development of several pharmaceutical products that improve patient health by delivering therapeutics from weeks to months. Over the last decade, due to its good biocompatibility, formulation tunability, wide range of degradation rates, and extensive clinical studies, polyester-based LAI technologies including poly(lactic-co-glycolic acid) (PLGA) have made substantial progress. Herein, we discuss PLGA properties with seminal approaches in the development of LAIs, the role of molecular dynamic simulations of polymer-drug interactions, and their effects on quality attributes. We also outline the landscape of various advanced PLGA-based and a few non-PLGA LAI technologies; their design, delivery, and challenges from laboratory scale to preclinical and clinical use; and commercial products incorporating the importance of end-user preferences.
Hydrogels that provide mechanical support and sustainably release therapeutics have been used to treat tendon injuries. However, most hydrogels are insufficiently tough, release drugs in bursts, and require cell infiltration or suturing to integrate with surrounding tissue. Here we report that a hydrogel serving as a high-capacity drug depot and combining a dissipative tough matrix on one side and a chitosan adhesive surface on the other side supports tendon gliding and strong adhesion (larger than 1,000 J m −2 ) to tendon on opposite surfaces of the hydrogel, as we show with porcine and human tendon preparations during cyclic-friction loadings. The hydrogel is biocompatible, strongly adheres to patellar, supraspinatus and Achilles tendons of live rats, boosted healing and reduced scar formation in a rat model of Achilles-tendon rupture, and sustainably released the corticosteroid triamcinolone acetonide in a rat model of patellar tendon injury, reducing inflammation, modulating chemokine secretion, recruiting tendon stem and progenitor cells, and promoting macrophage polarization to the M2 phenotype. Hydrogels with ‘Janus’ surfaces and sustained-drug-release functionality could be designed for a range of biomedical applications.
Long acting injectable formulations have been developed to sustain the action of drugs in the body over desired periods of time. These delivery platforms have been utilized for both systemic and local drug delivery applications. This review gives an overview of long acting injectable systems that are currently in clinical use. These products are categorized in three different groups: biodegradable polymeric systems, including microparticles and implants; micro and nanocrystal suspensions and oil-based formulations. Furthermore, the applications of these drug delivery platforms for the management of various chronic diseases are summarized. Finally, this review addresses industrial challenges regarding the development of long acting injectable formulations.
Glucocorticoids are well established anti-inflammatory agents, however, their use to treat chronic inflammatory diseases is limited due to a number of serious side effects. For example, long-term local treatment of chronic wounds with glucocorticoids is prohibited by dysregulation of keratinocyte and fibroblast function, leading to skin thinning. Here, we developed and tested liposome formulations for local delivery of dexamethasone to primary human macrophages, to drive an anti-inflammatory/pro-resolution phenotype appropriate for tissue repair. The liposomes were loaded with the pro-drug dexamethasone-phosphate and surface-modified with either polyethylene glycol or phosphatidylserine. The latter was used to mimic phosphatidylserine-harboring apoptotic cells, which are substrates for efferocytosis, an essential pro-resolution function. Both formulations induced a dexamethasone-like gene expression signature in macrophages, decreased IL6 and TNFα release, increased secretion of thrombospondin 1 and increased efferocytosis activity. Phosphatidylserine-modified liposomes exhibited a faster uptake, a higher potency and a more robust phenotype induction than polyethylene glycol-modified liposomes. Fibroblast and keratinocyte cell cultures as well as a 3D skin equivalent model showed that liposomes applied locally to wounds are preferentially phagocytosed by macrophages. These findings indicate that liposomes, in particular upon shell modification with phosphatidylserine, promote dexamethasone delivery to macrophages and induce a phenotype suitable to support chronic wound healing.
Background Carboxymethyl starch (CMS) and carboxymethylated hydroxyethyl starch (CM-HES) might offer advantages over hydroxyethyl starch (HES) with regard to their volume expansion effect and their pharmacokinetic characteristics. The goal of the current study was to determine the pharmacokinetics of CMS and CM-HES and to investigate their influence on blood coagulation in comparison with the standard low-molecular, low-substituted HES (130/0.42) used in Europe. Methods The study was conducted as a randomized, blinded, parallel three-group study in 30 pigs. Twenty ml/kg of 6% HES (control), 6% CMS, or 6% CM-HES was infused as a single dose, and serial blood sampling was performed over 20 h to measure plasma concentration and molecular weight and to assess blood coagulation. Concentration-effect relations were assessed by pharmacokinetic-pharmacodynamic analysis. Results CMS and CM-HES showed significantly higher plasma concentrations and molecular weights over 20 h (P for both<0.001) with smaller volumes of distribution and longer elimination rates during the terminal phase (P for both<0.01) when compared with HES. CMS and CM-HES impaired whole blood coagulation more than HES as assessed by Thrombelastograph analysis (Haemoscope Corporation, Niles, IL). However, similar effects of all three starch preparations on blood coagulation were found when related to the plasma concentrations in mass units. Conclusions Carboxymethylation of starch results in an increased intravascular persistence and a slower fragmentation compared with HES. The greater impairment of blood coagulation by CMS and CM-HES seems to be caused by the higher plasma concentrations.
Background High-molecular-weight, low-substituted hydroxyethyl starch (HES) may not affect blood coagulation more than low-molecular-weight, low-substituted HES. The authors assessed in vivo the effect of a lowered C2/C6 ratio on pharmacokinetic characteristics and the impact on blood coagulation of high-molecular-weight, low-substituted HES. Methods A prospective, randomized, parallel study in 30 pigs compared HES 650/0.42/2.8 with HES 650/0.42/5.6. Before, during, and after infusion of 30 ml/kg body weight HES, blood samples were collected over 630 min to measure HES concentrations and plasmatic coagulation and to assess blood coagulation in whole blood by Thrombelastography (TEG; Haemoscope Corporation, Niles, IL). Pharmacokinetic parameters were estimated using a two-compartment model. Results The elimination constant was 0.009 +/- 0.001 min(-1) for HES 650/0.42/2.8 and 0.007 +/- 0.001 min(-1) for HES 650/0.42/5.6 (P < 0.001); the area under the plasma concentration-time curve was 1,374 +/- 340 min x g/l for HES 650/0.42/2.8 and 1,697 +/- 411 min x g/l for HES 650/0.42/5.6 (P = 0.026). The measured plasma HES concentrations were not different between HES 650/0.42/2.8 and HES 650/0.42/5.6. Both HES solutions equally affected blood coagulation: Thrombelastographic coagulation index decreased similarly at the end of infusion of HES 650/0.42/2.8 and at the end of infusion of HES 650/0.42/5.6 (P = 0.293). Also, activated partial thromboplastin and prothrombin times increased similarly for HES 650/0.42/2.8 and HES 650/0.42/5.6 (P = 0.831). Conclusion Reducing the C2/C6 ratio in high-molecular, low-substituted HES solutions results in a slightly faster HES elimination. However, the blood coagulation compromising effect was unaffected.
BACKGROUND:Hydroxyethyl starches (HES) with lower impact on blood coagulation but longer intravascular persistence are of clinical interest. The current study aimed to investigate in vivo the isolated effect of molecular weight on blood coagulation during progressive acute normovolemic hemodilution. METHODS:Twenty-four pigs were normovolemically hemodiluted up to a total exchange of 50 ml . kg . body weight of HES 650/0.42 or HES 130/0.42. Serial blood sampling was performed to measure HES plasma concentration and to assess blood coagulation. Concentration-effect relations were analyzed by linear regression, followed by the Student t test on regression parameters. RESULTS:Blood coagulation was increasingly compromised toward hypocoagulability by acute normovolemic hemodilution with both treatments (P < 0.01). Significantly greater impact on activated partial thromboplastin time (P = 0.04) and significantly stronger decrease of maximal amplitude (P = 0.04), angle alpha (P = 0.02), and coagulation index (P = 0.02) was seen after acute normovolemic hemodilution with HES 650/0.42 as compared with HES 130/0.42. Except for factor VIII (P = 0.04), no significant differences between both treatments were observed when relating antihemostatic effects to HES plasma concentrations (P > 0.05). A significantly lesser decrease of hemoglobin concentration has been found with HES 650/0.42 as compared with HES 130/0.42 (P < 0.01) in relation to HES plasma concentrations. CONCLUSION:High-molecular-weight HES (650/0.42) shows a moderately greater antihemostatic effect than low-molecular-weight HES (130/0.42) during acute normovolemic hemodilution. However, similar effects on hemostasis were observed with both treatments when observed antihemostatic effects were related to measured HES plasma concentrations. In addition, HES 650/0.42 may have a lower efficacy in immediately restoring plasma volume.