We present the characterization of several atmospheric aerosol analogs in a tabletop chamber and an analysis of how the concentration of NaCl present in these aerosols influences their bulk optical properties. Atmospheric aerosols (e.g., fog and haze) degrade optical signal via light-aerosol interactions causing scattering and absorption, which can be described by Mie theory. This attenuation is a function of the size distribution and number concentration of droplets in the light path. These properties are influenced by ambient conditions and the droplet's composition, as described by Köhler theory. It is therefore possible to tune the wavelength-dependent bulk optical properties of an aerosol by controlling droplet composition. We present experimentation wherein we generated multiple microphysically and optically distinct atmospheric aerosol analogs using salt water solutions with varying concentrations of NaCl. The results demonstrate that changing the NaCl concentration has a clear and predictable impact on the microphysical and optical properties of the aerosol.
Event-based sensors are a novel sensing technology which capture the dynamics of a scene via pixel-level change detection. This technology operates with high speed (>10 kHz), low latency (10 μs), low power consumption (<1 W), and high dynamic range (120 dB). Compared to conventional, frame-based architectures that consistently report data for each pixel at a given frame rate, event-based sensor pixels only report data if a change in pixel intensity occurred. This affords the possibility of dramatically reducing the data reported in bandwidth-limited environments (e.g., remote sensing) and thus, the data needed to be processed while still recovering significant events. Degraded visual environments, such as those generated by fog, often hinder situational awareness by decreasing optical resolution and transmission range via random scattering of light. To respond to this challenge, we present the deployment of an event-based sensor in a controlled, experimentally generated, well-characterized degraded visual environment (a fog analogue), for detection of a modulated signal and comparison of data collected from an event-based sensor and from a traditional framing sensor.
A variety of methods have been used to study atmospheric bioaerosols. A common technique employed for the detection and measurement of bioaerosols is the measurement of the autofluorescence of biological particles when excited by ultraviolet light. We examined the changes in the fluorescence spectra of bioaerosols when exposed to ambient outdoor conditions for periods of several hours. The bioaerosols in this study were contained in a Captive Aerosol Growth and Evolution (CAGE) chamber that employed two rotating drums constructed with an exterior FEP Teflon film to allow sunlight to penetrate and an inner ePTFE membrane to allow ambient trace gasses to permeate the drums. The bioaerosols were periodically measured with a TSI UV-APS (excited at 355 nm) and a single-particle fluorescence spectrometer (excited at 351 and 263 nm). The data indicate changes in both fluorescence spectral profile and intensity from Bacillus thuringiensis var. kurstaki spores and MS2 bacteriophage particles during the experiments. The changes observed in these particles appear to be due to a combination of the environmental conditions rather than attributable to any single factor. The results of this study indicate that bioaerosols are significantly altered by atmospheric aging processes and that these changes may affect measurements by ultra-violet light induced fluorescence (UV-LIF) or other spectroscopic techniques.
We present optical metrology at the Sandia fog chamber facility. Repeatable and well characterized fogs are generated under different atmospheric conditions and applied for light transport model validation and computational sensing development.
High - temperature partic le receivers are being pursued to enable next - generation concentrating solar thermal power (CSP) systems that can achieve higher temperatures (> 700 C) to enable more efficient power cycles, lower overall system costs, and emerging CSP - based process - heat applications. The objective of this work was to develop c haracterization methods to quantify the particle and heat losses from the open aperture of the particle receiver. Novel camera - based imaging methods were developed and applied to both laboratory - scal e and larger 1 MW t on - sun tests at the National Solar The rmal Test Facility in Albuquerque, New Mexico. Validation of the imaging methods was performed using gravimetric and calorimetric methods. In addition, conventional particle - sampling methods using vo lumetric particle - air samplers were applied to the on - sun tests to compare particle emission rates with regulatory standards for worker safety and pollution. Novel particle sampling methods using 3 - D printed tipping buckets and tethered balloons were also developed and applied to the on - sun particle - receiver tes ts. Finally, models were developed to simulate the impact of particle size and wind on particle emissions and concentrations as a function of location. Results showed that particle emissions and conc entrations were well below regulatory standards for worke r safety and pollution. In addition, estimated particle temperatures and advective heat losses from the camera - based imaging methods correlated well with measured values during the on - sun tests.
Atmospheric fog is a common degraded visual environment (DVE) that reduces sensing and imaging range and resolution in complex ways not fully encapsulated by traditional metrics. As such, better physical models are required to describe imaging systems in a fog environment. We have developed a tabletop fog chamber capable of creating repeatable fog-like environments for controlled experimentation of optical systems within this common DVE. We present measurement of transmission coefficients and droplet size distribution in a multiple scattering regime using this chamber.
We present a computationally efficient a pproximate solution to the time-resolved radiative transfer equation that is applicable in weakly and diffuse scattering heterogeneous media. Applications will be considered, including computational sensing in fog and tissue.
A computationally efficient radiative transport model is presented that predicts a camera measurement and accounts for the light reflected and blocked by an object in a scattering medium. The model is in good agreement with experimental data acquired at the Sandia National Laboratory Fog Chamber Facility (SNLFC). The model is applicable in computational imaging to detect, localize, and image objects hidden in scattering media. Here, a statistical approach was implemented to study object detection limits in fog.
Degraded visual environments like fog pose a major challenge to safety and security because light is scattered by tiny particles. We show that by interpreting the scattered light it is possible to detect, localize, and characterize objects normally hidden in fog. First, a computationally efficient light transport model is presented that accounts for the light reflected and blocked by an opaque object. Then, statistical detection is demonstrated for a specified false alarm rate using the Neyman-Pearson lemma. Finally, object localization and characterization are implemented using the maximum likelihood estimate. These capabilities are being tested at the Sandia National Laboratory Fog Chamber Facility.
Abstract Airborne contaminants from fires containing nuclear waste represent significant health hazards and shape the design and operation of nuclear facilities. Much of the data used to formulate DOE-HDBK-3010-94, “Airborne Release Fractions/Rates and Respirable Fractions for Nonreactor Nuclear Facilities,” from the U.S. Department of Energy, were taken over 40 years ago. The objectives of this study were to reproduce experiments from Pacific Northwest Laboratories conducted in June 1973 employing current aerosol measurement methods and instrumentation, develop an enhanced understanding of particulate formation and transport from fires containing nuclear waste, and provide modeling and experimental capabilities for updating current standards and practices in nuclear facilities. A special chamber was designed to conduct small fires containing 25 mL of flammable waste containing lutetium nitrate, ytterbium nitrate, or depleted uranium nitrate. Carbon soot aerosols showed aggregates of primary particles ranging from 20 to 60 nm in diameter. In scanning electron microscopy, ~200-nm spheroidal particles were also observed dispersed among the fractal aggregates. The 200-nm spherical particles were composed of metal phosphates. Airborne release fractions (ARFs) were characterized by leaching filter deposits and quantifying metal concentrations with mass spectrometry. The average mass-based ARF for 238U experiments was 1.0 × 10−3 with a standard deviation of 7.5 × 10−4. For the original experiments, DOE-HDBK-3010-94 states, “Uranium ARFs range from 2 × 10−4 to 3 × 10−3, an uncertainty of approximately an order of magnitude.” Thus, current measurements were consistent with DOE-HDBK-3010-94 values. ARF values for lutetium and ytterbium were approximately one to two orders of magnitude lower than 238U. Metal nitrate solubility may have varied with elemental composition and temperature, thereby affecting ARF values for uranium surrogates (Yb and Lu). In addition to ARF data, solution boiling temperatures and evaporation rates can also be deduced from experimental data.
In response to personal protective equipment (PPE) shortages in the United States due to the Coronavirus Disease 2019, two models of N95 respirators were evaluated for reuse after gamma radiation sterilization. Gamma sterilization is attractive for PPE reuse because it can sterilize large quantities of material through hermetically sealed packaging, providing safety and logistic benefits. The Gamma Irradiation Facility at Sandia National Laboratories was used to irradiate N95 filtering facepiece respirators to a sterilization dose of 25 kGy(tissue). Aerosol particle filtration performance testing and electrostatic field measurements were used to determine the efficacy of the respirators after irradiation. Both respirator models exhibited statistically significant decreases in particle filtering efficiencies and electrostatic potential after irradiation. The largest decrease in capture efficiency was 40-50% and peaked near the 200 nm particle size. The key contribution of this effort is correlating the electrostatic potential change of individual filtration layer of the respirator with the decrease filtration efficiency after irradiation. This observation occurred in both variations of N95 respirator that we tested. Electrostatic potential measurement of the filtration layer is a key indicator for predicting filtration efficiency loss.
. Generation 3 particle-base concentrating solar power systems utilize solid media in the form of absorptive, sand-like particles as the heat-transfer fluid and thermal-energy-storage medium to increase the maximum operating temperature of concentrating solar power technology to over 800°C. The particles fall as a curtain through an open aperture receiver cavity to directly absorb thermal energy from the concentrated solar flux. Abrasion due to particle-to-particle and particle-to-surface interaction within particle based concentrating solar power systems creates dust that escapes through the receiver aperture. The dust present in the receiver cavity may result in beam attenuation and mass loss decreasing the efficiency of the receiver. A design for a dust removal loop is presented with preliminary testing demonstrating its ability to reduce the dust present in a 1 MW th falling particle receiver with an 8 kg/s mass flow rate. The particle dust removal loop reduced the mass of particle dust present in the receiver by 46% compared to steady operation with ambient temperature particles.
Shortages of N95 respirators for use by medical personnel have driven consideration of novel conservation strategies, including decontamination for reuse and extended use. Decontamination methods listed as promising by the Centers for Disease Control and Prevention (CDC) (vaporous hydrogen peroxide (VHP), wet heat, ultraviolet irradiation (UVI)) and several methods considered for low resource environments (bleach, isopropyl alcohol and detergent/soap) were studied for two commonly used surgical N95 respirators (3M™ 1860 and 1870+ Aura™). Although N95 filtration performance depends on the electrostatically charged electret filtration layer, the impact of decontamination on this layer is largely unexplored. As such, respirator performance following decontamination was assessed based on the fit, filtration efficiency, and pressure drop, along with the relationship between (1) surface charge of the electret layer, and (2) elastic properties of the straps. Decontamination with VHP, wet heat, UVI, and bleach did not degrade fit and filtration performance or electret charge. Isopropyl alcohol and soap significantly degraded fit, filtration performance, and electret charge. Pressure drop across the respirators was unchanged. Modest degradation of N95 strap elasticity was observed in mechanical fatigue testing, a model for repeated donnings and doffings. CDC recommended decontamination methods including VHP, wet heat, and UV light did not degrade N95 respirator fit or filtration performance in these tests. Extended use of N95 respirators may degrade strap elasticity, but a loss of face seal integrity should be apparent during user seal checks. NIOSH recommends performing user seal checks after every donning to detect loss of appropriate fit. Decontamination methods which degrade electret charge such as alcohols or detergents should not be used on N95 respirators. The loss of N95 performance due to electret degradation would not be apparent to a respirator user or evident during a negative pressure user seal check.
Random scattering and absorption of light by tiny particles in aerosols, like fog, reduce situational awareness and cause unacceptable down-time for critical systems or operations. Computationally efficient light transport models are desired for computational imaging to improve remote sensing capabilities in degraded optical environments. To this end, we have developed a model based on a weak angular dependence approximation to the Boltzmann or radiative transfer equation that appears to be applicable in both the moderate and highly scattering regimes, thereby covering the applicability domain of both the small angle and diffusion approximations. An analytic solution was derived and validated using experimental data acquired at the Sandia National Laboratory Fog Chamber facility. The evolution of the fog particle density and size distribution were measured and used to determine macroscopic absorption and scattering properties using Mie theory. A three-band (0.532, 1.55, and 9.68 µm) transmissometer with lock-in amplifiers enabled changes in fog density of over an order of magnitude to be measured due to the increased transmission at higher wavelengths, covering both the moderate and highly scattering regimes. The meteorological optical range parameter is shown to be about 0.6 times the transport mean free path length, suggesting an improved physical interpretation of this parameter.
High-temperature falling particle receivers are being investigated for next-generation concentrating solar power applications. Small sand-like particles are released into an open-cavity receiver and are irradiated by concentrated sunlight from a field of heliostats. The particles are heated to temperatures over 700 °C and can be stored to produce heat for electricity generation or industrial applications when needed. As the particles fall through the receiver, particles and particulate fragments in the form of aerosolized dust can be emitted from the aperture, which can lower thermal efficiency, increase costs of particle replacement, and pose a particulate matter (PM) inhalation risk. This paper describes sampling methods that were deployed during on-sun tests to record near-field (several meters) and far-field (tens to hundreds of meters) concentrations of aerosol particles within emitted plumes. The objective was to quantify the particulate emission rates and loss from the falling particle receiver in relation to OSHA and EPA National Ambient Air Quality Standards (NAAQS). Near-field instrumentation placed on the platform in proximity to the receiver aperture included several real-time aerosol size distribution and concentration measurement techniques, including a TSI Aerodynamic Particle Sizers (APS), TSI DustTraks, Handix Portable Optical Particle Spectrometers (POPS), Alphasense Optical Particle Counters (OPC), TSI Condensation Particle Counters (CPC), Cascade Particle Impactors, 3D-printed prototype tipping buckets, and meteorological instrumentation. Far-field particle sampling techniques utilized multiple tethered balloons located upwind and downwind of the particle receiver to measure the advected plume concentrations using a suite of airborne aerosol and meteorological instruments including POPS, CPCs, OPCs and cascade impactors. The combined aerosol size distribution for all these instruments spanned particle sizes from 0.02 μm – 500 μm. Results showed a strong influence of wind direction on particle emissions and concentration, with preliminary results showing representative concentrations below both the OSHA and NAAQS standards.