Cervical ultrasound (US) is crucial in the follow-up of differentiated thyroid cancer (DTC). However, there are no guidelines for its acquisition and documentation, particularly concerning the role of additional video sequences, known as US cine loops (UCL). The aim of this study is to examine the clinical relevance (CR) of a new Standard Operating Procedure (SOP) for cervical UCL in DTC follow-up. A retrospective analysis was conducted on all UCL examinations of DTC follow-up patients at a tertiary care center between January 2010 and February 2018 to determine their clinical significance. The patients were divided into two groups: those with no documented CR (UCL-nCR) and those with documented CR (UCL-CR). The study reviewed the respective written medical US reports that were validated by experienced residents. The UCL-CR were categorized in: confirmation of a suspicious finding that was identified during conventional live US (UCL-CRcon), identification of a suspicious finding that was not identified during conventional live US (UCL-CRide), and invalidation of a suspicious finding that was identified during conventional live US (UCL-CRinv). A total of 5512 UCLs in 652 DTC patients were analyzed, with 71.5
The influence of the interventional treatment approach for transarterial radioembolization (TARE) on the incidence of extrahepatic microsphere depositions and to angiographic complications was evaluated. In total, 398 TARE cycles were analyzed. Interventional treatment approaches were classified as single treatment position (TP) with interventional occlusion (IO), multiple TPs without IO, and multiple TPs with IO. Correlations with extrahepatic microsphere depositions, angiographic complications, and periprocedural clinical events were performed. Alternative treatment strategies were evaluated. Applications from multiple TPs could have ensured the safe application of microspheres in 48.2% of cases that were originally performed from a single TP after IO. Extrahepatic microsphere accumulations were detected after 5.2%, 5.3%, and 1.5% of TARE procedures from a single TP without IO, a single TP with IO, and multiple TPs without IO, respectively. Applications from multiple TPs did not increase angiographic complications. During the 30-day follow-up, nausea/vomiting and upper abdominal discomfort were observed more frequently in the group with IO than in the group without IO (7.9%/4.6% and 9.2%/5.9%, respectively). In many TARE procedures, the same target liver can be treated from multiple TPs instead of a single TP, reducing the need for the interventional occlusion of aberrant arteries and potential extrahepatic microsphere depositions.
Abstract A 66-year-old woman was referred with an incidental finding of a bilateral papillary thyroid microcarcinoma after thyroidectomy. On the right side, a Warthin-like variant was observed. After radioiodine therapy, whole-body scan revealed an unclear iodine uptake on the right-sided neck. For further clarification, 131I-SPECT/US and 18F-PET/US fusion imaging were performed, unambiguously revealing iodine and glucose uptake within a hypoechoic lesion located in the parenchyma of the right parotid gland. Surgical excision confirmed a Warthin tumor ipsilateral to the Warthin-like variant of the papillary thyroid microcarcinoma. Because the extensive imaging, targeted minimal-invasive surgery was possible.
Abstract A 64-year-old man with metastatic castration-resistant prostate cancer presented for prostate-specific membrane antigen (PSMA) PET/CT in preparation for 177Lu-PSMA radioligand therapy. For precedent BRCA mutation assessment, fine-needle aspiration cytology of 2 PSMA-positive lymph node metastases was conducted. The acquired material was suitable for next-generation sequencing-based gene panel diagnostics and did not show a BRCA1/2 mutation, thus PSMA radioligand therapy was initiated. Fine-needle aspiration cytology of lymph node metastases may be a viable option in evaluating further therapeutic alternatives.
Hepatobiliary scintigraphy is a well-established nuclear imaging method for evaluating liver function and displaying the biliary system, but the spatial and temporal resolution is limited, and, there is still no established PET equivalent. Adapted from the work of Schuhmacher et al. in 1983, the production of a 68Gallium-labeled substitute, tetrabromophthalein ([68Ga]Ga-BP-IDA), was undertaken according to current Good Manufacturing Practice (GMP) standards and proved feasible and reproducible. PET/CT with the radiotracer was performed in two complex patients with hepatocellular carcinoma in preparation for transarterial radioembolization. Due to its high spatial and temporal resolution, localization of areas with impaired liver function and visualization of the biliary system were possible. We could demonstrate that this 68Gallium-labeled, IDA-based PET tracer is feasible and could advance hepatic and biliary function PET imaging.
The differentiation of splenic tissue from malignant lesions via imaging may be challenging, particularly considering aberrant or accessory lesions and diseases that are rarely encountered. Functioning splenic tissue can be identified using technetium-99m red blood cell (99mTc-RBC) scintigraphy, but its sensitivity is limited and may not be available. We present the case of a patient in whom disseminated abdomino-pelvic splenosis was diagnosed using PET/CT with gallium-68-oxine-labeled RBCs. The method represents a feasible and probably superior alternative to splenic scintigraphy.
Purpose Renal function and effective half-life ( t 1/2,eff ) of I-131 have not been fully elucidated in patients undergoing radioiodine therapy (RAIT) for differentiated thyroid cancer (DTC). Aim of the present analysis was to evaluate the potential of cystatin C-based estimated glomerular filtration rate (eGFR CysC ) in comparison to conventional creatinine (eGFR Crea ) and to verify which methods to determine t 1/2,eff are most accurate to predict t 1/2,eff . Methods Forty-eight patients receiving whole-body I-131-scintigraphy were included. eGFR CysC was compared to eGFR Crea with regard to accuracy of t 1/2,eff prediction. Three different methods (i.e. blood-based, gamma camera-based and probe-based) and two protocols with either three (short period,SP; up to 42 h) or four (long period,LP; up to 114 h) time points were compared using the Akaike’s information criterion. Results The eGFR CysC measurement is more likely than eGFR Crea in predicting the t 1/2,eff . High correlation coefficients were found between t 1/2,eff assessed by gamma camera and probe measurements and blood-based determination revealed lower values. Patients with normal eGFR showed higher values of t 1/2,eff of LP compared to SP. Conclusions eGFR CysC should be included in further study protocols. As camera and probe measurements lead to almost superimposable results, one of the methods is expendable. Blood-based results of t 1/2,eff were lower, presumably due to unspecific iodine retention, whereas the lower correlation with renal function may be caused by individual differences in intestinal iodine resorption. SP-protocols up to 42 h after I-131 administration are sufficient to determine t 1/2,eff . Further studies are necessary for specific recommendations regarding I-131 activity reduction during RAIT in patients with DTC and renal insufficiency.