Objective To develop partial least squares regression (PLSR) calibration models in combination with transmission infrared (TIR) spectroscopy for rapid and optimal quantification of human milk macronutrient concentrations. Study design Human milk samples (n = 306) were characterized simultaneously by reference chemical analytical methods and TIR spectroscopy. Reference macronutrient concentrations were linked to pre-processed spectra and divided into two (training and test) sets. PLSR was used to develop trial calibration models using training set, and the test set was used to assess the accuracy of the trial analytical methods. Results For the methods selected as optimal, the concordance correlation coefficients between reference and TIR-based methods were 0.93 for fat, 0.96 for protein, and 0.52 for lactose. The Bland-Altman plots showed no evidence of systematic bias between TIR and reference methods. Conclusions TIR spectroscopy provides the basis for accurate and rapid quantification of human milk fat and protein concentrations but is less accurate for measuring lactose concentration.
Attenuated total reflectance infrared (ATR-IR) spectroscopy is a simple, rapid and cost-effective method for the analysis of serum. However, the complex nature of serum remains a limiting factor to the reliability of this method. We investigated the benefits of coupling the centrifugal ultrafiltration with ATR-IR spectroscopy for quantification of human serum IgA concentration. Human serum samples (n = 196) were analyzed for IgA using an immunoturbidimetric assay. ATR-IR spectra were acquired for whole serum samples and for the retentate (residue) reconstituted with saline following 300 kDa centrifugal ultra filtration. IR-based analytical methods were developed for each of the two spectroscopic datasets, and the accuracy of each of the two methods compared. Analytical methods were based upon partial least squares regression (PLSR) calibration models - one with 5-PLS factors (for whole serum) and the second with 9-PLS factors (for the reconstituted retentate). Comparison of the two sets of IR-based analytical results to reference IgA values revealed improvements in the Pearson correlation coefficient (from 0.66 to 0.76), and the root mean squared error of prediction in IR-based IgA concentrations (from 102 to 79 mg/dL) for the ultrafiltration retentate-based method as compared to the method built upon whole serum spectra. Depleting human serum low molecular weight proteins using a 300 kDa centrifugal filter thus enhances the accuracy IgA quantification by ATR-IR spectroscopy. Further evaluation and optimization of this general approach may ultimately lead to routine analysis of a range of high molecular-weight analytical targets that are otherwise unsuitable for IR-based analysis. (C) 2017 Elsevier B.V. All rights reserved.
The objective of this study was to develop and compare the performance of laboratory grade and portable attenuated total reflectance infrared (ATR-IR) spectroscopic approaches in combination with partial least squares regression (PLSR) for the rapid quantification of alpaca serum IgG concentration, and the identification of low IgG (<1000 mg/dL), which is consistent with the diagnosis of failure of transfer of passive immunity (FTPI) in neonates. Serum samples (n = 175) collected from privately owned, healthy alpacas were tested by the reference method of radial immunodiffusion (RID) assay, and laboratory grade and portable ATR-IR spectrometers. Various pre-processing strategies were applied to the ATR-IR spectra that were linked to corresponding RID-IgG concentrations, and then randomly split into two sets: calibration (training) and test sets. PLSR was applied to the calibration set and calibration models were developed, and the test set was used to assess the accuracy of the analytical method. For the test set, the Pearson correlation coefficients between the IgG measured by RID and predicted by both laboratory grade and portable ATR-IR spectrometers was 0.91. The average differences between reference serum IgG concentrations and the two IR-based methods were 120.5 mg/dL and 71 mg/dL for the laboratory and portable ATR-IR-based assays, respectively. Adopting an IgG concentration <1000 mg/dL as the cut-point for FTPI cases, the sensitivity, specificity, and accuracy for identifying serum samples below this cut point by laboratory ATR-IR assay were 86, 100 and 98%, respectively (within the entire data set). Corresponding values for the portable ATR-IR assay were 95, 99 and 99%, respectively. These results suggest that the two different ATR-IR assays performed similarly for rapid qualitative evaluation of alpaca serum IgG and for diagnosis of IgG <1000 mg/dL, the portable ATR-IR spectrometer performed slightly better, and provides more flexibility for potential application in the field.
Second Edition of the Encyclopedia of Spectroscopy and Spectrometry pulls key information into a single source for quick access to answers and/or in-depth examination of topics. SPEC-2 covers theory, methods, and applications for researchers, students, and professionals - combining proven techniques and new insights for comprehensive coverage of the field. The content is available in print and online via ScienceDirect, the latter of which offers optimal flexibility, accessibility, and usability through anytime, anywhere access for multiple users and superior search functionality. No other work gives analytical and physical (bio)chemists such unprecedented access to the literature. With 30% new content, SPEC-2 maintains the 'authoritative, balanced coverage' of the original work while also breaking new ground in spectroscopic research. The key features of the book include: incorporates more than 150 color figures, 5,000 references, and 300 articles (30% of which are new), for a thorough examination of the field; highlights new research and promotes innovation in applied areas ranging from food science and forensics to biomedicine and health; and features a new co-editor: David Koppenaal of Pacific Northwest National Laboratory, Washington, USA, whose work in atomic mass spectrometry has been recognized internationally.
Transmission infrared (IR) spectroscopy, in combination with partial least squares (PLS) regression, was used as the basis to develop a new method to quantify IgG in bovine colostrum. Colostrum samples (n = 250) were tested simultaneously by the reference radial immunodiffusion (RID) assay and IR spectroscopy. Colostral IgG concentrations obtained by RID assay were linked to pre-processed spectra and divided into two sets, i.e., calibration and test. PLS regression was applied to the calibration set and calibration models were developed, and the test set was used to assess the accuracy of the analytical method. The Pearson and concordance correlations between test set IgG concentrations as determined by the IR assay and the RID assay were 0.91. The Bland-Altman plot showed no evidence of systematic bias between IR and RID methods. Transmission IR spectroscopy is an effective method for quantification of bovine colostral IgG concentration and for assessment of colostrum quality. (C) 2015 Elsevier Ltd. All rights reserved.
In this study, we evaluated and compared the performance of transmission and attenuated total reflectance (ATR) infrared (IR) spectroscopic methods (in combination with quantification algorithms previously developed using partial least squares regression) for the rapid measurement of bovine serum immunoglobulin G (IgG) concentration, and detection of failure of transfer of passive immunity (FTPI) in dairy calves. Serum samples ( n = 200) were collected from Holstein calves 1–11 days of age. Serum IgG concentrations were measured by the reference method of radial immunodiffusion (RID) assay, transmission IR (TIR) and ATR-IR spectroscopy-based assays. The mean IgG concentration measured by RID was 17.22 g/L (SD ±9.60). The mean IgG concentrations predicted by TIR and ATR-IR spectroscopy methods were 15.60 g/L (SD ±8.15) and 15.94 g/L (SD ±8.66), respectively. RID IgG concentrations were positively correlated with IgG levels predicted by TIR ( r = 0.94) and ATR-IR ( r = 0.92). The correlation between 2 IR spectroscopic methods was 0.94. Using an IgG concentration <10 g/L as the cut-point for FTPI cases, the overall agreement between TIR and ATR-IR methods was 94%, with a corresponding kappa value of 0.84. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for identifying FTPI by TIR were 0.87, 0.97, 0.91, 0.95, and 0.94, respectively. Corresponding values for ATR-IR were 0.87, 0.95, 0.86, 0.95, and 0.93, respectively. Both TIR and ATR-IR spectroscopic approaches can be used for rapid quantification of IgG level in neonatal bovine serum and for diagnosis of FTPI in dairy calves.
Immunoglobulin G (IgG) is crucial for the protection of the host from invasive pathogens. Due to its importance for human health, tools that enable the monitoring of IgG levels are highly desired. Consequently there is a need for methods to determine the IgG concentration that are simple, rapid, and inexpensive. This work explored the potential of attenuated total reflectance (ATR) infrared spectroscopy as a method to determine IgG concentrations in human serum samples. Venous blood samples were collected from adults and children, and from the umbilical cord of newborns. The serum was harvested and tested using ATR infrared spectroscopy. Partial least squares (PLS) regression provided the basis to develop the new analytical methods. Three PLS calibrations were determined: one for the combined set of the venous and umbilical cord serum samples, the second for only the umbilical cord samples, and the third for only the venous samples. The number of PLS factors was chosen by critical evaluation of Monte Carlo-based cross validation results. The predictive performance for each PLS calibration was evaluated using the Pearson correlation coefficient, scatter plot and Bland-Altman plot, and percent deviations for independent prediction sets. The repeatability was evaluated by standard deviation and relative standard deviation. The results showed that ATR infrared spectroscopy is potentially a simple, quick, and inexpensive method to measure IgG concentrations in human serum samples. The results also showed that it is possible to build a united calibration curve for the umbilical cord and the venous samples.
BACKGROUND:Following the recent development of a new approach to quantitative analysis of IgG concentrations in bovine serum using transmission infrared spectroscopy, the potential to measure IgG levels using technology and a device better designed for field use was investigated. A method using attenuated total reflectance infrared (ATR) spectroscopy in combination with partial least squares (PLS) regression was developed to measure bovine serum IgG concentrations. ATR spectroscopy has a distinct ease-of-use advantage that may open the door to routine point-of-care testing. Serum samples were collected from calves and adult cows, tested by a reference RID method, and ATR spectra acquired. The spectra were linked to the RID-IgG concentrations and then randomly split into two sets: calibration and prediction. The calibration set was used to build a calibration model, while the prediction set was used to assess the predictive performance and accuracy of the final model. The procedure was repeated for various spectral data preprocessing approaches.RESULTS:For the prediction set, the Pearson's and concordance correlation coefficients between the IgG measured by RID and predicted by ATR spectroscopy were both 0.93. The Bland Altman plot revealed no obvious systematic bias between the two methods. ATR spectroscopy showed a sensitivity for detection of failure of transfer of passive immunity (FTPI) of 88 %, specificity of 100 % and accuracy of 94 % (with IgG <1000 mg/dL as the FTPI cut-off value).CONCLUSION:ATR spectroscopy in combination with multivariate data analysis shows potential as an alternative approach for rapid quantification of IgG concentrations in bovine serum and the diagnosis of FTPI in calves.
Research into osteoarthritis diagnostics has evolved from traditional methods that are only useful in more advanced clinical disease, towards the discovery of biomarkers that are predictive or reflective of preclinical joint disease. The potential of Fourier transform infrared spectroscopy (FTIR) coupled with chemometrics has been demonstrated as useful for the assessment of biomolecular responses to disease. Joint fluid was collected from 105 clinically normal antebrachiocarpal (AC), midcarpal (MC) and tarsocrural (TCRL) joints. Thin films were prepared and FTIR absorbance spectra in the mid-infrared region recorded. Interferograms were signal averaged and Fourier transformed to generate spectra with a nominal resolution of 4 cm-1. Comparisons among joints were made using a novel modified method similar to linear discriminant analysis, which maximized the difference of between-group variance minus within-group variance, followed by permutation testing. Differences within animal between contralateral pairs of joints were minimal. Significant differences among AC, MC and TCRL joint fluid spectra were found. The range of biomolecular differences among these normal joints as characterized by FTIR indicates that interarticular variation within the horse needs to be considered for ongoing research, especially when utilizing within-horse joints as controls.
Simple, rapid and cost-effective methods are sought for measuring immunoglobulin G (IgG) concentrations in bovine serum, which can be applied for diagnosis of failure of transfer of passive immunity (FTPI). The aim of the present study was to investigate the potential use of Fourier-transform infrared (FTIR) spectroscopy, with partial least squares (PLS) regression, to measure IgG concentrations in bovine serum. Serum samples collected from calves and adult cows were tested in parallel by radial immunodiffusion (RID) assay and FTIR spectroscopy. The sample IgG concentrations obtained by the RID method were linked to pre-processed spectra and divided into two sets: a combined set and a test set. The combined set was used for building a calibration model, while the test set was used to assess the predictive ability of the calibration model, resulting in a root mean squared error of prediction (RMSEP) of 307.5 mg/dL.The concordance correlations between the IgG measured by RID and predicted by FTIR spectroscopy were 0.96 and 0.93 for the combined and test data sets, respectively. Analysis of the data using the Bland-Altman method did not show any evidence of systematic bias between FTIR spectroscopy and RID methods for measurement of IgG. The clinical applicability of FTIR spectroscopy for diagnosis of FTPI was evaluated using the entire data set and showed a sensitivity of 0.91 and specificity of 0.96, using RID as the reference standard. The FTIR spectroscopy method, described in the present study, demonstrates potential as a rapid and reagent-free tool for quantification of IgG in bovine serum, as an aid to diagnosis of FTPI in calves. (C) 2014 Elsevier Ltd. All rights reserved.
A rapid, simple, and inexpensive method to measure the immunoglobulin G (IgG) concentrations in blood samples in human and veterinary medicine is highly desired. Infrared spectroscopy (coupled with chemometric manipulation of spectral data) has the advantages of simple sample preparation, rapid implementation of analysis, and low cost. Here a method that exploits infrared spectroscopy as the basis to measure IgG concentration in animal plasma samples is reported, with radial immunodiffusion (RID) used as the reference test method for partial least squares (PLS) calibration model development. Smoothed non-derivative and the second-order derivative spectra were used to develop calibration models. Various additional spectral preprocessing steps were evaluated to optimize the calibration models, and the possible benefits of using an internal standard (potassium thiocyanate [KSCN]) were investigated. Monte Carlo cross-validation was used to determine the optimal number of PLS factors, and an independent prediction set was used to test the predictive performances of provisional models. The effects of various preprocessing options (spectral smoothing, derivation, normalization, region selection, mean-centering, and standard deviation scaling) on quantification accuracy were investigated. The root mean squared error of prediction (RMSEP) for different combinations of spectra preprocessing steps was 394 ± 36 mg/dL for the non-derivative spectra and 427 ± 101 mg/dL for the second-order derivative spectra. Immunoglobulin G concentrations produced by the optimized PLS model for the non-derivative spectra (RMSEP = 352 mg/dL) were found to be stable with respect to different splits of the samples among the calibration, validation, and prediction sets. The precision of the Fourier transform infrared (FT-IR) method is found to be slightly superior to that of the RID method. The results of this work indicate that infrared spectroscopy is a promising technique for economically and rapidly determining the IgG concentrations of plasma and plasma-derived samples.
Moulds, notably Stachybotrys chartarum (atra), are constant contributors to air pollution particularly to air quality in buildings.The spores themselves or their volatile organic products are present in variable amounts in almost all environments, particularly in buildings affected by flooding.These moulds and products can account for the sick building syndrome and have been tied to such occurrences as the outbreak of pulmonary hemosiderosis and hemorrhage in infants in Cleveland, Ohio.The present study was designed to investigate the effects of S. chartarum extracts on surfactant protein expression, surfactant quality and cell survival in the developing lung.S. chartarum extracts were incubated with cultures of several cell types; isolated fetal lung type II cells and fetal lung fibroblasts, and human lung A549 cells, a continuously growing cell line derived from surfactant producing type II alveolar cells.MTT formazan assays were employed to test cell viability.The synthesis and release of the predominant surfactant protein A (SP-A), which is involved in the regulation of surfactant turnover and metabolism, and surfactant protein B (SP-B) involved in shuttling phospholipids between surfactant subcompartments was also assessed.Antibodies to these proteins and western blotting results were used to assess the quantity of protein produced by the various cell types.A novel approach utilizing captive bubble surfactometry was employed to investigate the quality of surfactant in terms of surface tension and bubble volume measurements.Elec-tron microscopy was used to examine changes in cellular structure of control and S. chartarum-treated cells.Results of the study showed that exposure to the S. chartarum extracts had deleterious effects on fetal lung epithelial cell viability and their ability to produce pulmonary surfactant.S. chartarum extracts also induced deleterious changes to the developing fetal lung cells in terms of expression of SP-A and SP-B as well as to the surface tension reducing abilities of the pulmonary surfactant.Ultrastructurally, spore toxin associated changes were apparent in the isolated lung cells most notably in the lamellar bodies of fetal rat lung alveolar type II and human A549 cells.This study has demonstrated the potential damage to surfactant production and function which may be induced by inhaling S. chartarum toxins.
Smoking during pregnancy is a major source of fetal exposure to numerous harmful agents present in tobacco smoke. Lung development involves complex biochemical processes resulting in dramatic changes which continue even after birth. In addition to type I cells which form the blood-air barrier, type II alveolar epithelial (AE) cells have important and diverse functions related to immunological protection and stabilization of the alveolus through synthesis and secretion of the pulmonary surfactant. Apoptosis or programmed cells death is an important physiological process during lung embryogenesis and for the proper maintenance of homeostasis. Caspases are proteases that play important roles in regulating apoptosis. Caspase-3 is the key executioner caspase in the cascade of events leading to cell death by apoptosis. We explored the hypothesis that cigarette smoke extract (CSE) induces apoptosis in fetal rat lung type II AE cells by activation of caspase-3. To analyze these factors, isolated fetal rat lung type II AE cells were used. The cells were exposed to different concentrations of CSE (5%, 10% or 15%) (v/v) for 60 min. The results of the present study showed that CSE induced apoptosis in fetal rat lung type II AE cells with a significant increase (p 0.05) in caspase-3 activity and decrease in cell proliferation at CSE concentrations of 10% and 15% (v/v). These observations indicate that cigarette smoke extract induces apoptosis by activation of caspase-3 in fetal rat lung type II AE cells in a dose-dependent manner and may potentially alter the regulated development of the lung and the appearance of the surfactant-producing type II alveolar cells which are critical for the establishment of adequate gas exchange at birth.
BACKGROUND:Cigarette smoking is the leading cause of preventable death and has been implicated in pathogenesis of pulmonary, oral and systemic diseases. Smoking during pregnancy is a risk factor for the developing fetus and may be a major cause of infant mortality. Moreover, the oral cavity, and all cells within are the first to be exposed to cigarette smoke and may be a possible source for the spread of toxins to other organs of the body. Fibroblasts in general are morphologically heterogeneous connective tissue cells with diverse functions. Apoptosis or programmed cell death is a crucial process during embryogenesis and for the maintenance of homeostasis throughout life. Deregulation of apoptosis has been implicated in abnormal lung development in the fetus and disease progression in adults. Caspases are proteases which belong to the family of cysteine aspartic acid proteases and are key components for downstream amplification of intracellular apoptotic signals. Of 14 known caspases, caspase-3 is the key executioner of apoptosis. In the present study we explored the hypothesis that cigarette smoke (CS) extract activates caspase-3 in two types of fibroblasts, both of which would be exposed directly to cigarette smoke, isolated fetal rat lung fibroblasts and adult rat periodontal ligament (PDL) fibroblasts.METHODS:Isolated fetal rat lung fibroblasts and adult PDLs were used. Cells were exposed to different concentrations of CS for 60 min. Caspase-3 activity and its inhibition by Z-VAD-fmk were measured by caspase-3 fluorometric assay. The effect of CSE on cellular viability was measured using the MTT formazan assay. Caspase-3 expression was detected by western blot analysis and cellular localization of caspase-3 was determined by immunofluorescence using fluorescence microscopy.RESULTS:It was observed in fetal rat lung fibroblast cells that CSE extract significantly (p<0.05) increased caspase-3 activity and decrease cell proliferation. However, no significant changes in activity or viability were observed in PDLs.CONCLUSIONS:This indicates CS activates caspase-3 the key regulatory point in apoptosis in fetal rat lung fibroblast cells suggesting that smoking during pregnancy may alter the developmental program of fetal lung, jeopardizing the establishment of critical cellular mechanisms necessary to expedite pulmonary maturation at birth.of critical cellular mechanisms necessary to expedite pulmonary maturation at birth.
Infrared spectroscopy can be used to identify and quantify individual (bio)chemical species within complex mixtures provided the spectroscopic fingerprints are strong enough. It is often the case, however, that the characteristic fingerprints are concealed by the much stronger absorptions of the most concentrated species. For example, in the case of blood serum, the very strong absorptions of protein severely hinder detection of diagnostically relevant metabolites. A microfluidic device [1,2] is modeled here with the objective of separating serum metabolites from proteins, or – more precisely – to enhance the metabolite/protein concentration ratio, and in so doing to provide a new metabolite-rich sample for spectroscopic characterization [3-5]. Focusing upon a representative metabolite (creatinine) and protein (albumin) we have modeled the diffusion of serum components into a water stream when the two streams flow in contact through a microchannel. With the laminar fluid diffusion interface (LFDI) thus created, creatinine diffuses rapidly into the water, while the albumin hardly diffuses at all. Thus, at the channel exit one may recover a product containing significant creatinine but very little albumin. The goal of the simulations is to predict the composition of the product stream. To that end, we have tested various two-dimensional models to see if the essential features are contained in them. Various fluid mechanical insights are found: diverging flow at the inlet, converging and separating flow at the exit, and the difference between 2D and 3D simulation results.
The laminar fluid diffusion interface (LFDI) is a microfluidic tool that manipulates the composition of liquid mixtures by exploiting differences among diffusion coefficients of the dissolved components. One application is the preprocessing of (bio)fluids prior to spectroscopic characterization. For example, in the case of infrared (IR) spectroscopy, the technique can improve sensitivity to low-concentration serum metabolites. The practical benefit is "metabolic fingerprinting" measurements that are more sensitive to low-concentration metabolites than are the counterpart measurements for the original serum sample. Optimal use of the LFDI technique has proven elusive, since the composition of the product of interest is very sensitive to the choice of flow rates for the liquid streams entering and emerging from the LFDI channel. To provide the basis for optimal use, this study had the objective of developing a simulation package that predicts the composition of the LFDI product, given the LFDI structural and operating parameters. To demonstrate the utility of the simulations, composition of the LFDI products predicted for two illustrative sets of trials were compared with experimental data. The flow rates thus derived provided a LFDI product that is relatively rich in serum metabolites, while largely depleted of protein, and very well suited for subsequent IR spectroscopic characterization.