Electrospray ionization (ESI) is a dynamic process that, when coupled with mass spectrometry (MS), serves as an invaluable tool for analysis of biomolecules. Our group, as well as others, has observed that there is a bias in signal intensity for one strand of a PCR amplicon over the complementary strand in an ESI mass spectrum. In this report, we have investigated the contributions of hydrophobicity and free energy of solvation to relative signal intensities in ESI-MS spectra of nucleic acids. We developed approaches for predicting which strand of the PCR amplicon will be the most intense: one based on a rate equation for calculating ion flux using values from the literature for hydrophobicity and free energy of solvation and the other based on the percentage of the relatively hydrophilic guanines present in the strand. A trend in signal intensity for deoxyribonucleotide triphosphates, oligonucleotides, and PCR amplicons was observed that was consistent with our model. On the basis of the observation that increased hydrophobicity correlates with greater signal intensity, we selectively enhanced the signal intensity of a 20-mer with the addition of an alkyl chain to the 5' terminus, which subsequently improved the limit of detection to 1 nM, an improvement by 1 order of magnitude. This was extended to a 53-bp PCR amplicon by modifying one primer with the hydrophobic moiety, which resulted in a 16% increase in signal intensity. We capitalized on this result to determine allele frequencies from pooled DNA for single-nucleotide polymorphisms down to 1%.
The experimental determination of average mass by mass spectrometry is limited for large molecules due to the negative bias introduced by the natural distribution of isotopic abundances. This results in the measurement of the top-of-centroid (ToC) as opposed to the true centroid. We have developed a practical correction factor that is applied to the ToC measurement to largely remove the systematic bias introduced by nature. The correction factor is calculated easily using the average molecular mass (<100 kDa) of the analyte molecule and the full-width half maximum resolving power (<3,500) of the measurement. In addition, an approach to calculating resolving power is described that accurately predicts resolving power achievable for Fourier transform ion cyclotron resonance (FT-ICR) mass analysis of large molecules. A combination of internal calibration with a dual-electrospray source and application of the correction factor to average mass measurements improved the mass error from 192.5 to -35.0 ppm for a 44 kDa PCR amplicon.
The advantages of the thermostable DNA polymerase from Thermococcus kodakaraensis (KOD) are demonstrated for PCR amplification with subsequent detection by mass spectrometry. Commonly used DNA polymerases for PCR amplification include those from Thermus aquaticus (Taq) and Pyrococcus furiosus (Pfu). A 116 base-pair PCR product derived from a vWA locus was amplified by Taq, Pfu, or KOD DNA polymerase and compared by agarose gel electrophoresis and electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR-MS). KOD DNA polymerase demonstrated a 2- to 3-fold increase in PCR product formation compared to Pfu or Taq, respectively, and generated blunt-ended PCR product which allows facile interpretation of the mass spectrum. Additionally, we demonstrate the advantage of using high magnetic fields to obtain unit resolution of the same 116 base pair (∼72 kDa) PCR product at high m/z.
Electrospray ionization mass spectrometry (ESI-MS) is a powerful technique used for the identification and characterization of DNA polymorphisms. Continual improvement in instrument design assures high mass measurement accuracy, sensitivity, and resolving power. This work describes an eclectic array of enzymatic strategies we have invoked in order to detect single-nucleotide polymorphisms by ESI-MS, although other applications may be envisioned. One strategy combines the use of two enzymes, exonuclease III and lambda exonuclease, to provide a ladder of single-stranded DNA fragments for straightforward sequence identification by mass spectrometry. A second strategy combines restriction enzymes to screen for polymorphisms present within specific amplicons. Finally, we describe the use of stable-isotope-labeled nucleotides for the determination of length and base composition of a PCR product.
An online database has been established in order to validate electrospray ionization mass spectrometry (ESI-MS) for genotyping and to publicize the procedures developed in our laboratory for the characterization of PCR products by ESI-MS. Genotypes derived from short tandem repeat (STR) loci that were obtained using ESI Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) have been posted for fifteen members of the CEPH family 1362 pedigree. The website provides specific information such as PCR parameters, PCR product cleanup approaches, and ESI solution compositions to enable other laboratories to reproduce our data. Links are provided to related websites in an effort to integrate information regarding the CEPH family, STR genotyping, and mass spectrometry. The database, currently available at http://www.people.vcu.edu/ -dcmuddim/genotype/ will be routinely updated with genotypes from additional STR loci including PCR parameters as well as PCR cleanup strategies as further developments are completed.
A universal dual-electrospray (ESI) source is demonstrated on a quadrupole orthogonal-accelerated time-of-flight mass spectrometer (Q-ToF-MS) for both genomic and proteomic applications. This facile source modification enables internal calibration for consistent mass measurements by a mainstream MS platform and requires no mixing of analyte and calibrant prior to ion formation. In this report, the dual-sprayer is demonstrated in the negative-ion mode for internal calibration of polymerase chain reaction (PCR) amplicons generated from synthetic and genomic templates as well as a proteolytic digest of a naturally phosphorylated protein. For all PCR amplicons, experimentally determined average mass measurements are well within the instrument specifications of better than 0.01%. For the proteolytic fragments of the phosphoprotein, average mass errors of the isotopically resolved peptides are better than 10 ppm.
Elimination of PCR buffer components and alkali metal cations (i.e., Na+, K+) is of critical importance to allow for accurate mass measurements of PCR products for genotyping and sequencing applications. Ethanol precipitation followed by microdialysis has been repeatedly shown to efficiently desalt PCR products for analysis by mass spectrometry and is considered the gold standard. Alternative cleanup techniques that are compatible with automation are explored here with the intent of expanding the bottleneck that exists between the production of PCR products and analysis by electrospray ionization mass spectrometry (ESI-MS). Numerous combinations of approaches were evaluated that included PCR purification kits and alcohol precipitations. The data shown here support alternative approaches to an ethanol precipitation followed by microdialysis that have comparable desalting efficiency and can be utilized for cleanup of PCR products generated from single reactions.
The recent completion of the first rough draft of the human genome has provided fundamental information regarding our genetic make-up; however, the post-genome era will certainly require a host of new technologies to address complex biological questions. In particular, a rapid and accurate approach to characterize genetic markers, including short tandem repeats (STRs) and single nucleotide polymorphisms (SNPs) is demanded. STRs are the most informative of the two polymorphisms owing to their remarkable variability and even dispersity throughout eukaryotic genomes. Mass spectrometry is rapidly becoming a significant method in DNA analysis and has high probability of revolutionizing the way in which scientists probe the human genome. It is our responsibility as biomolecular mass spectrometrists to understand the issues in genetic analysis and the capabilities of mass spectrometry so that we may fulfill our role in developing a rapid, reliable technology to answer specific biological questions. This perspective is intended to familiarize the mass spectrometry community with modern genomics and to report on the current state of mass spectrometry, specifically electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry, for characterization of STRs.
Electrospray ionization Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometry is a rapidly emerging, universal platform with the ability to provide detailed information regarding genetic variation and the up- and down regulation of their cognate gene products. Herein, we report our progress towards the development of ESI-FTICR mass spectrometry for the characterization of genomic regions which contain both a length and sequence polymorphism (i.e., complex short tandem repeats). Specifically, it is demonstrated for the first time that a high-quality ESI-FTICR mass spectrum of a 82-bp double- stranded PCR product derived from a single, 50 (mu) L PCR reaction with less than 10 X 10-15 moles injected into the mass spectrometer can be routinely obtained. It is important to note that each measurement, which translates to an accurate genotype, is completed on the timescale of seconds. Progress towards the implementation of flow- injection analysis methodology to increase the throughput is also presented using an alternating injection of a 15-mer and 16-mer oligonucleotide.
Electrospray ionization mass spectrometry (ESI-MS) has been utilized to obtain accurate mass measurements of intact PCR products; however, single-stranded PCR products are necessary to detect sequence modifications such as base substitutions, additions or deletions. The locations of these modifications can subsequently be determined using additional stages of mass spectrometry. The recombinant enzyme lambda exonuclease selectively digests one strand of a DNA duplex from a 5' phosphorylated end leaving the complementary strand intact. Using this rapid enzymatic step, we were able to produce single-stranded PCR products by digestion of an intact PCR product derived from the Human Tyrosine Hydroxylase (HUMTHO1) gene, which contains a tetrameric repeating motif. The non-template directed 3' adenylation common when using Taq polymerase resulted in three distinct species (blunt-ended, mono-adenylated and di-adenylated), which added complexity to the spectrum of the double-stranded product. The data from the single-stranded products shows that one strand is preferentially adenylated over the other, which cannot be determined from the mass spectrum of the double-stranded PCR product alone. The ESI-FTICR (Fourier transform ion cyclotron resonance) mass spectra of the lambda exonuclease treated PCR products exhibited less than expected signal-to-noise (S/N) ratios. This is attributed to inaccurate concentration calculations due to remaining double-stranded PCR product amplified with unphosphorylated primers, and to matrix effects contributed by the lambda exonuclease reaction buffer. To further test this hypothesis, we investigated and determined the limit of detection to be 0.27 microM using standard curve statistics for single acquisitions of a synthetic 75-mer. The concentrations of the noncoding and coding strands produced by lambda exonuclease digestion were calculated to be 0.29 and 0.37 microM, respectively, taking into account the presence of double-stranded product. The products were electrosprayed from concentrations at the limit of detection requiring the averaging of 5-10 acquisitions to produce a sufficient S/N ratio, indicating that product concentration, base composition and matrix effects play a combined, significant role in detection of lambda exonuclease treated PCR products. Although additional work will be required to further exploit this strategy, lambda exonuclease clearly provides mass spectrometrists with a method to generate single-stranded PCR products.