The Euro 7 standard for Heavy-Duty (HD) vehicles introduces stricter Solid Particle Number (SPN) emission limits by reducing In-Service Conformity (ISC) thresholds from 9.8 × 1011 #/kWh to 9.0 × 1011 #/kWh and lowering the minimum detectable particle size from 23 nm (SPN23) to 10 nm (SPN10). SPN emissions are excluded from active regeneration of Diesel Particulate Filters (DPFs), but passive regeneration during ISC testing remains a regulated condition for HD vehicles. These stricter regulations underscore the pressing need for advanced DPF technologies to ensure compliance under real-world operating conditions. In this study, a Euro VI Step E HD vehicle was evaluated on an HD chassis dynamometer using a predefined real-world ISC testing route to assess SPN emissions during passive regeneration of soot-loaded DPFs. Two SPN instruments, one downstream of the DPF and one downstream of the subsequent Selective Catalytic Reduction (SCR), allowed for a parallel characterization of the DPF performance and the net SPN increase observed across the SCR system. The tests indicate that passive regeneration in Euro VI vehicles can lead to SPN10 emissions as high as 23 × 1011 #/kWh with current technology DPFs. However, the advanced DPF technology limited weighted DPF-out SPN10 emissions to 1.2 × 1011 #/kWh, below the net increase observed across the SCR system (2.3 × 1011 to 2.9 × 1011 #/kWh), even during passive regeneration events, presenting a feasible pathway for achieving compliance with future emission standards.
Some European Heavy Duty (HD) vehicle manufacturers have adopted Open Crankcase Ventilation (OCV) systems to improve reliability and performance. The emission compliance of HD vehicles both during certification and In-Service Conformity (ISC) testing need to also account for the crankcase ventilation. Despite that, the contribution of crankcase emissions to the overall emissions profile of modern trucks remains underexplored. This study experimentally characterizes the crankcase emissions of a Euro VI Step E HD truck equipped with an OCV system under controlled conditions on a chassis dynamometer. Emissions were measured over the World Harmonized Vehicle Cycle (WHVC) and an ISC-compliant driving cycle at two test cell temperatures. The results indicate that crankcase emissions account for up to 4% and 8% of the current regulatory limits for nitrogen oxides (NOx) and 23 nm solid particle number (SPN23), respectively. The tightening of NOx limits under Euro 7 regulations would increase these contributions to approximately 11%. SPN10 crankcase emissions were found to be on the order of 1011 (11% of the Euro 7 limit). Real-time SPN10 and SPN23 measurements revealed that the fraction of nanosized particles increases significantly during cold start, suggesting increased oil combustion within the cylinder. These findings highlight the need to refine crankcase emissions measurement procedures within regulatory frameworks. A systematic investigation of measurement setups and ageing effects, taking into account variations in OCV system designs and piston ring wear, is essential to determine whether characterization during certification is sufficient or if ISC testing throughout the vehicle’s useful life will be required.
The Particle Measurement Programme Informal Working Group (PMP-IWG) coordinated a global interlaboratory study (ILS) on brake wear particle emissions with the participation of 16 testing facilities. Two articles present the main outcomes of the ILS: (I) Particulate matter mass (PM), and (II) Particle Number (PN) emissions. The test matrix covered a wide variety of brake systems and configurations. The tested disc brakes were found to emit PM2.5 and PM10 that varied between 0.8–4.0 mg/km and 2.2–9.5 mg/km per brake, respectively, depending on the type of brake and the applied testing load. The drum brake emitted much lower PM due to its enclosed nature. Almost 37–45% of the emitted PM falls in the fine particle size with this fraction being higher for the drum brake. On the other hand, almost 50–65% of the total brake mass loss falls in particle sizes larger than 10 μm or gets lost before being measured. The most important loss mechanisms for PM in the proposed layout are being discussed. Finally, the PM measurement variability and lab-to-lab reproducibility are investigated.
The upcoming Euro 7 regulation for Heavy-Duty (HD) vehicles is calling for a further tightening of the Solid Particle Number (SPN) emissions by means of both lowering the applicable limits and shifting the lowest detectable size from 23 nm (SPN23) to 10 nm (SPN10). A late-technology diesel HD truck was tested on a chassis dynamometer in order to assess the necessary particle filtration requirements for a continuously regenerating system. The study showed that passive regeneration under real-world operating conditions can lead to a significant release of SPN10 particles from the current technology Diesel Particulate Filter (DPF) when soot-loaded, even exceeding the currently applicable emission limits. The actual emissions during passive regeneration and following the clean-up of the DPF exceeded the proposed Euro 7 limits by more than an order of magnitude. A prototype DPF, exhibiting a 99% filtration efficiency when clean, was shown to effectively control SPN10 emissions under both operating conditions. The shift to SPN10 also necessitates control of nanoparticles forming inside the Selective Catalytic Reduction (SCR) system, which for the tested truck exceeded the proposed (hot) limit by up to 56%. A dedicated particle filter specifically designed to capture these particles was also evaluated, showing a better than 60% efficiency. The key message of this study is that SPN emissions can be kept at low levels under all conditions.
The stringency of vehicle exhaust emissions regulations resulted in a significant decrease in exhaust particulate matter (PM) emissions over the years. Non-exhaust particles (i.e., from brakes and tyres) account for almost half or more of road transport-induced ambient PM. Even with the internal combustion engine ban in 2035, electrified vehicles will still emit PM from brake and tyre wear. Consequently, non-exhaust PM emissions cannot decrease significantly without any regulatory measures. Because independent research carried out under different methods is not readily comparable, a Global Technical Regulation (GTR), which sets the procedures and boundaries of testing brake wear particle emissions, is currently under development. This overview describes the particle number (PN) measurement setup based on the well-known exhaust emissions PN methodology. We provide the technical requirements and the expected maximum losses. In addition, we estimate the effect of particle losses on the differences between different setups for typical size distributions observed during brake testing. Finally, we compare brake testing PN specifications to those of exhaust PN.
Vehicles' exhaust particulate matter (PM) emissions have significantly decreased over the years. On the other hand, non-exhaust emissions, i.e., particle emissions from brakes and tires, have increased due to the increase in the vehicle fleet, traffic congestion, and the distance traveled. As a result, regulatory bodies are investigating the possibility of mitigating non-exhaust emissions. The Euro 7 proposal introduces specific emission limits for both brakes and tires for the first time in a regulation worldwide. The methodology for brake particle emissions sampling and measurement builds on the work of the Particle Measurement Programme (PMP) informal working group of the United Nations Economic Commission for Europe (UNECE). The recently adopted Global Technical Regulation (GTR) on brakes from light-duty vehicles up to 3.5 t prescribes the technical details. In this paper, we present the technical specifications for the measurements of PM. We also evaluate the penetrations for two cases with two setups for minimum and maximum particle losses. This study, using aerosol engineering calculations, estimates the maximum expected differences between the two setups, both of which are compliant with the GTR. This study also discusses the mass ratios of PM2.5 and PM10 as a function of the mass median diameters.
Condensation particle counters (CPCs) use light scattering to count particles after they have grown to micron size in a supersaturated environment. In single counting mode each particle is counted depending on whether the scattered light exceeds a threshold value or not. In photometric mode the total scattered light is converted in particle number concentration. While for laboratory grade particle number systems, CPCs are allowed to operate only in single counting mode, there is no such requirements for portable emissions measurements systems (PEMS) for real-driving emissions (RDE) testing or for instruments for periodic technical inspection (PTI) of vehicles. In this study two CPCs of the same model were assessed in single counting and photometric modes with silver and graphite particles with sizes ranging from 10 nm to 100 nm. The results showed that the concentration was measured accurately enough for particles in the 25 nm to 50 nm size range, but was underestimated and overestimated for smaller and larger particles, respectively. The key message is that the photometric mode should be avoided or calibrated in function of concentration and particle size.
The Particle Measurement Programme (PMP) informal working group co-ordinated a global interlaboratory study (ILS) on brake wear particle emissions with the participation of 16 laboratories in 2021. Two articles present the results of the ILS: (I) particulate matter mass (PM) and (II) particle number (PN) emissions. The test matrix covered different brake systems, including ECE and NAO pad materials with grey cast iron discs and a drum brake. Regarding PN, the study measured the total particle number from approximately 10 nm to 2.5 µm (TPN). Some testing facilities measured solid particle number emissions (SPN) in parallel. The mean TPN concentrations ranged from 9.1 × 108 #/km/brake to 1.1 × 1010 #/km/brake. TPN and SPN emission levels were comparable, except for one lab that measured very high volatile particle emissions for one brake system. The minimum and maximum SPN emissions for a given brake differed by a factor of 2.5 ± 0.5, comparable to data from exhaust SPN ILS measurements. This article provides an overview of lessons learned and subsequent measures incorporated in an upcoming global technical regulation to reduce measurement variability when sampling and measuring brake particle emissions for light-duty vehicles up to 3.5 t.
Concerns regarding noxious emissions from internal combustion engines have increased over the years. There is a strong need to understand the nature of sub-23 nm particles and to develop measurement techniques to evaluate the feasibility of new regulations for particle number emissions in the sub-23 nm region (down to at least 10 nm). This paper presents the results of three EU-funded projects (DownToTen, PEMs4Nano and SUREAL-23) which supported the understanding, measurement and regulation of particle emissions below 23 nm and have successfully developed sub-23 nm particle measurement devices, specifically laboratory systems and mobile devices for RDE tests. The new technology was validated in chassis dyno tests and on the real road. The results show that sub-23 nm particles are mainly generated at the engine start and during acceleration phases. The innovations show that the technology is mature and robust enough to serve as a basis for regulating sub-23 nm particles.
Many countries worldwide have introduced a limit for solid particles larger than 23 nm for the type approval of vehicles before their circulation in the market. However, for some vehicles, in particular for port fuel injection engines (gasoline and gas engines) a high fraction of particles resides below 23 nm. For this reason, a methodology for counting solid particles larger than 10 nm was developed in the Particle Measurement Programme (PMP) group of the United Nations Economic Commission for Europe (UNECE). There are no studies assessing the reproducibility of the new methodology across different laboratories. In this study we compared the reproducibility of the new 10 nm methodology to the current 23 nm methodology. A light-duty gasoline direct injection vehicle and two reference solid particle number measurement systems were circulated in seven European and two Asian laboratories which were also measuring with their own systems fulfilling the current 23 nm methodology. The hot and cold start emission of the vehicle covered a range of 1 to 15 × 1012 #/km with the ratio of sub-23 nm particles to the >23 nm emissions being 10–50%. In most cases the differences between the three measurement systems were ±10%. In general, the reproducibility of the new methodology was at the same levels (around 14%) as with the current methodology (on average 17%).
A heavy-duty engine is type-approved in engine dynamometers, while its in-service conformity is controlled on the road. In the first case, laboratory particle number systems (LABS) sample from a full dilution tunnel or a proportional partial flow dilution system (PFDS). In the second case portable emissions measurements systems (PEMS) measure directly from the tailpipe. Permitting in the regulation LABS sampling directly from the tailpipe would simplify testing and would improve their comparability with PEMS. In this study PEMS and LABS, both sampling from the tailpipe and measuring solid particles >10 nm, were compared with references systems (i.e. LABS from PFDS). One compressed natural gas (CNG) engine, and three diesel engines, all Euro VI step E, with or without urea injection, and with or without crankcase ventilation connected to the tailpipe, challenged the systems with different emission levels and particle sizes and properties. The results showed that the differences of the LABS to the references were in most cases within ±25%, with a few exceptions. The PEMS were within ±50%. There was no or small effect on the differences from engine technology, urea injection or crankcase ventilation. The inclusion of sub-23 nm particles increased 100% to 250% the particle number emissions. The urea injection increased the >10 nm emissions 300–600% (2–5 × 1010 p/kWh). Connecting the crankcase ventilation to the tailpipe further increased the >10 nm particle number emissions 340–560% (1.4–2.5 × 1011 p/kWh), bringing the >10 nm levels of the engines to approximately half of the current particle number limit, applicable to particles >23 nm.
The European Commission (EC) is in the process of finalizing the proposal for the upcoming legislative stage for light- and heavy-duty vehicles. The emission performance over extended operating conditions is under consideration. Furthermore, a tightening of the Solid Particle Number (SPN) limits with a parallel shift of the lowest detectable size from 23 to 10 nm has been suggested. This paper investigates the SPN emission performance of a Euro VI step E HDV and the potential offered by an advanced Diesel Particulate Filter (DPF) to meet the upcoming regulations. Cold start emissions at clean DPF state were found to be as high as 1.3 × 1012 #/kWh, while passive regeneration events could lead to hot start emissions of 3 × 1011 #/kWh. Improvements in the filtration efficiencies at clean state, similar to those offered by the advanced DPF (>99%), will be needed to tackle these operating conditions. The measurements also revealed the formation of 10 nm SPN in the Selective Catalytic Reduction (SCR) system, at a rate of ~1.2 × 1011 #/kWh. These levels lie above the proposed limit of 1011 #/kWh, highlighting the need to also control these non-volatile nanosized particles.
"Brake wear is well recognized as one of the dominant sources of traffic-induced particulate matter emissions. A first standardized measurement methodology is currently being developed by UNECE's Particle Measurement Program. The approach is based on isolated single brakes on dedicated brake test beds, where the test conditions can be tightly controlled. However, the actual real-world emission behaviour of a brake system is influenced by many changing factors depending on the vehicle and a multitude of surrounding conditions. This makes real driving emissions measurement of brake dust a highly relevant but also very challenging task, considering minimal impact of the measurement setup on the emission behaviour. In this paper, we show the design of a novel brake particle sampling system with minimal influence on the thermal behaviour of the brake, supported by numerical simulation studies. The proposed setup covers only part of the brake disc on one side and allows for installation with minimal interventions at the brake mount and rim. The particle-collecting grommet and the sampling line were carefully designed to minimize larger particle losses. The sampling system was implemented in a commercial passenger car and equipped with particulate matter measurement instruments, closely following the ongoing standardization for brake dyno emission testing. Repeated real driving tests on a test track were successfully performed with different sampling flow rates. The results demonstrate the validity of the proposed approach, indicating promising particulate matter collection efficiency with sufficiently high sampling flow. "
The particle emissions from a commercial brake system utilizing copper-free pads have been characterized on a brake dynamometer under two real-world driving cycles. These included a novel cycle developed from analysis of the database of the World Harmonized Test Procedure (WLTP-Brake) and a short version of the Los Angeles City Traffic cycle (3h-LACT) developed in the framework of the European LowBraSys project. Disc temperature measurements using an array of embedded thermocouples revealed a large temporal and spatial non-uniformity with the radial temperature distribution depending also on the test procedure. Averaging over the duration of the cycle, it effectively reduced the influence of thermocouple positioning, allowing for more reliable quantification of the effectiveness of convective cooling. Particulate Matter (PM) emissions were similar for both cycles with PM2.5 averaging at 2.2 (±0.2) mg/km over the WLTP-Brake and 2.2 (±0.2) mg/km over the 3h-LACT, respectively. The corresponding PM10 emissions were 5.6 (±0.2) mg/km and 8.6 (±0.7) mg/km, respectively. The measurements revealed the formation of nanosized particles peaking at 10 nm, which were thermally stable at 350 °C under both cycles. Volatile nanoparticles were observed over the more demanding 3h-LACT cycle, with their emission rates decreasing with increasing the tunnel flow, suggesting nucleation of organic vapors released during braking as a potential formation process.
The current particle size threshold of the European Particle Number (PN) emission standards is 23 nm. This threshold could change because future combustion engine vehicle technology may emit large amounts of sub-23 nm particles. The Horizon 2020 funded project DownToTen (DTT) developed a sampling and measurement method to characterize particle emissions in this currently unregulated size range. A PN measurement system was developed based on an extensive review of the literature and laboratory experiments testing a variety of PN measurement and sampling approaches. The measurement system developed is characterized by high particle penetration and versatility, which enables the assessment of primary particles, delayed primary particles, and secondary aerosols, starting from a few nanometers in diameter. This paper provides instruction on how to install and operate this Portable Emission Measurement System (PEMS) for Real Drive Emissions (RDE) measurements and assess particle number emissions below the current legislative limit of 23 nm.
The particle number (PN) emissions of vehicles equipped with particulate filters are low. However, there are technologies that can have high PN levels, especially below the currently lower regulated particle size of 23 nm. Sub-23-nm particles are also considered at least as dangerous as the larger ultrafine particles. For this reason, the European Union (EU) is planning to regulate particles down to 10 nm. In this study we compared prototype portable emission measurement systems (PEMS) and reference laboratory systems measuring from 10 nm. The tests included cycles and constant speeds, using vehicles fuelled with diesel, gasoline or liquefied petroleum gas (LPG). The results showed that the PEMS were within ±40% of the reference systems connected to the tailpipe and the dilution tunnel. Based on the positive findings and the detection efficiencies of the prototype instruments, a proposal for the technical specifications for the future regulation was drafted.