The objective of the present study was to validate the presence and explore the characteristics of mitochondrial permeability transition (mPT) in isolated mitochondria from human heart tissue in order to investigate if previous findings in animal models of cardiac disorders are translatable to human disease. Mitochondria were rapidly isolated from fresh atrial tissue samples obtained from 14 patients undergoing Maze surgery due to atrial fibrillation. Human heart mitochondria exhibited typical mPT characteristics upon calcium overload such as swelling, evaluated by changes in light scattering, inhibition of respiration and loss of respiratory coupling. Swelling was a morphologically reversible event following transient calcium challenge. Calcium retention capacity (CRC), a quantitative measure of mPT sensitivity assayed by following extramitochondrial [Ca(2+)] and changes in respiration during a continuous calcium infusion, was significantly increased by cyclophilin D (CypD) inhibitors. The thiol-reactive oxidant phenylarsine oxide sensitized mitochondria to calcium-induced mPT. Release of the pro-apoptotic intermembrane protein cytochrome c was increased after, but not before, calcium discharge and respiratory inhibition in the CRC assay. From the present study, we conclude that adult viable heart mitochondria have a CypD- and oxidant-regulated mPT. The findings support that inhibition of mPT may be a relevant pharmacological target in human cardiac disease and may underlie the beneficial effect of cyclosporin A in reperfusion injury.
Objective. Lipid embolizations from retransfused shed blood during cardiac surgery have been shown to enter the circulation and end up in different organs. The purpose of this investigation was to evaluate differences in the kinetics and deposition between emulsified and non-emulsified lipid emboli in a porcine model. Design. Twelve animals were anesthetized and put on cardiopulmonary bypass. A shed-blood phantom (6 animals given emulsified and 6 given non-emulsified lipids) was produced from arterial blood, saline, and tritium-labeled triolein. The phantom was infused into the cardiopulmonary bypass circuit. Arterial and venous blood samples were taken at short intervals. Tissue samples were taken post-mortem from examined organs and prepared for scintillation counting. Levels of radioactivity were used to measure lipid emboli content in blood and tissue. Results. Emulsified lipid emboli generated a 5-fold higher embolic load in the arterial and a 12-fold higher in the venous circulation, compared with non-emulsified lipid emboli. Emulsified lipid micro emboli resulted in a 2–15-fold higher tissue deposition in investigated organs compared with non-emulsified lipid micro emboli. Conclusions. This study shows that the state of emulsion significantly alter the kinetics and tissue deposition of lipid emboli. Emulsified lipid emboli give higher embolic load in the arterial and venous circulation, and higher tissue deposition versus non-emulsified lipid emboli. In both groups, the embolic load was higher in the arterial circulation than on the venous side.
A major problem in clinical lung transplantation is the shortage of donor lungs. Only about 20% of donor lungs are accepted for transplantation. We have recently reported the results of the first six double lung transplantations performed with donor lungs reconditioned ex vivo that had been deemed unsuitable for transplantation by the Scandiatransplant, Eurotransplant, and UK Transplant organizations because the arterial oxygen pressure was less than 40 kPa. The three-month survival of patients undergoing transplant with these lungs was 100%. One patient died due to sepsis after 95 days, and one due to rejection after 9 months. Four recipients are still alive and well 24 months after transplantation, with no signs of bronchiolitis obliterans syndrome. The donor lungs were reconditioned ex vivo in an extracorporeal membrane oxygenation circuit using STEEN solution mixed with erythrocytes, to dehydrate edematous lung tissue. Functional evaluation was performed with deoxygenated perfusate at different inspired fractions of oxygen. The arterial oxygen pressure was significantly improved in this model. This ex vivo evaluation model is thus a valuable addition to the armamentarium in increasing the number of acceptable lungs in a donor population with inferior arterial oxygen pressure values, thereby, increasing the lung donor pool for transplantation. In the following paper we present our clinical experience from the first six patients in the world. We also present the technique we used in detail with flowchart.
Shed blood is known to be a source of lipid micro-emboli in cardiac surgery. The aim of this study was to characterize the occurrence of these particles at different stages of the operation, and to study their occurrence in the circulation at multiple time-points after the retransfusion of shed blood. Forty-four patients undergoing routine surgery with cardiopulmonary bypass were included. Blood was sampled from the surgical field at different sampling locations during the operation. Shed blood was collected in a transfusion bag and retransfused. After which, blood was sampled from the arterial line of the heart-lung machine. A Coulter counter was used for particle determinion. The mean volume of shed blood collected was 340"215 ml. Particles in the size range 10-60 mm were found at varying concentrations, with the highest concentrations being found in blood collected after cannulation and from the pleura. After retransfusion of this blood, a biphasic response was seen in the blood drawn from the efferent line of the heart-lung machine. Particles are found in shed blood at all times during cardiac surgery, and when this blood was retransfused an increase was seen in particle concentration in the heart-lung machine.
Background Retransfusion of the patient's own blood during surgery is used to reduce the need for allogenic blood transfusion. It has however been found that this blood contains lipid particles, which form emboli in different organs if the blood is retransfused on the arterial side. In this study, we tested whether retransfusion of blood containing lipid micro-particles on the venous side in a porcine model will give hemodynamic effects. Methods Seven adult pigs were used. A shed blood surrogate containing 400 ml diluted blood and 5 ml radioactive triolein was produced to generate a lipid embolic load. The shed blood surrogate was rapidly (<2 minutes) retransfused from a transfusion bag to the right atrium under general anesthesia. The animals' arterial, pulmonary, right and left atrial pressure were monitored, together with cardiac output and deadspace. At the end of the experiment, an increase in cardiac output and pulmonary pressure was pharmacologically induced to try to flush out lipid particles from the lungs. Results A more than 30-fold increase in pulmonary vascular resistance was observed, with subsequent increase in pulmonary artery pressure, and decrease in cardiac output and arterial pressure. This response was transient, but was followed by a smaller, persistent increase in pulmonary vascular resistance. Only a small portion of the infused triolein passed the lungs, and only a small fraction could be recirculated by increasing cardiac output and pulmonary pressure. Conclusion Infusion of blood containing lipid micro-emboli on the venous side leads to acute, severe hemodynamic responses that can be life threatening. Lipid particles will be trapped in the lungs, leading to persistent effects on the pulmonary vascular resistance.
Shed blood is known to be a source of lipid micro-emboli in cardiac surgery. The aim of this study was to characterize the occurrence of these particles at different stages of the operation, and to study their occurrence in the circulation at multiple time-points after the retransfusion of shed blood. Forty-four patients undergoing routine surgery with cardiopulmonary bypass were included. Blood was sampled from the surgical field at different sampling locations during the operation. Shed blood was collected in a transfusion bag and retransfused. After which, blood was sampled from the arterial line of the heart-lung machine. A Coulter counter was used for particle determinion. The mean volume of shed blood collected was 340+/-215 ml. Particles in the size range 10-60 microm were found at varying concentrations, with the highest concentrations being found in blood collected after cannulation and from the pleura. After retransfusion of this blood, a biphasic response was seen in the blood drawn from the efferent line of the heart-lung machine. Particles are found in shed blood at all times during cardiac surgery, and when this blood was retransfused an increase was seen in particle concentration in the heart-lung machine.
BACKGROUND:A major problem in clinical lung transplantation is the shortage of donor lungs. Only about 20% of donor lungs are accepted for transplantation. A method to evaluate and recondition lungs ex vivo has been tested on donor lungs that have been rejected for transplantation.METHODS:The donor lungs were reconditioned ex vivo in an extracorporeal membrane oxygenation (ECMO) circuit with STEEN solution (Vitrolife AB, Kungsbacka, Sweden) mixed with erythrocytes. The hyperoncotic solution dehydrates edematous lung tissue. Functional evaluations were performed with deoxygenated perfusate by varying the inspired fraction of oxygen. After the reconditioning, the lungs were kept immersed at 8 degrees C in extracorporeal membrane oxygenation until transplantation was performed.RESULTS:Six of nine initially rejected donor lungs were reconditioned to acceptable function, and in six recipients, double lung transplantation was performed. Three-month survival was 100%. One patient has since died due to sepsis after 95 days, and one due to rejection after 9 months. Four recipients are alive and well without any sign of bronchiolitis obliterans syndrome 24 months after the transplantation.CONCLUSIONS:The result from the present study is promising, and we continue to transplant reconditioned lungs.
Objectives: The platelet ADP P2Y(12) receptor which is a target for the antithrombotic drug clopidogrel is also distributed on vascular smooth muscle cells and stimulate contraction. This study investigates whether AZD6140, in contrast to clopidogrel, can inhibit ADP-mediated arterial contractions.Methods: Mice were treated with clopidogrel, 50 mg/kg, 24 and 2 h before experiment. Thoracic aorta ring segments from both clopidogrel-treated (n=5) and untreated (n=4) mice were mounted in myograph baths. Contractions of human left internal mammary arteries (IMA) and small arteries were studied in an identical manner.Results: Clopidogrel treatment per os did not inhibit contractions by the stable ADP analogue 2-MeSADP (10 mu M). However, addition of 1 mu M AZD6140 in vitro inhibited ADP contraction (% of maximal contraction by 60 mM K+) both in the clopidogrel-treated, from 64% to 32% (P=0.002) and in the untreated group, from 59% to 33% (P=0.015). 2-MeSADP contractions in human IMA and small arteries were inhibited by AZD6140.Conclusions: The antiplatelet drug AZD6140 blocks the contractile effects of ADP in both murine and human vasculature. These effects of AZD6140 could be beneficial in the management of conditions in which vasospasm may play a role. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
BACKGROUND:Shed mediastinal blood is known to be a source of microemboli in cardiac surgery. The aim of this study was to characterize in detail the lipid particles found in this blood. METHODS:Blood samples were collected from 24 patients undergoing routine cardiac surgery with cardiopulmonary bypass. Arterial and shed blood was analyzed using the Coulter counter technique to establish the number and size of particles. The composition of these lipid particles was compared with that of adipose tissue from the mediastinum using gas chromatography. Scanning electron microscopy was used to visualize the lipid particles in samples of shed blood. RESULTS:Lipid particles in the size range of 10 to 60 microm were characterized in shed mediastinal blood, and more than 300,000 particles per milliliter of blood were found. Triglyceride profiles in these lipid particles and in adipose tissue were similar, suggesting that their origin is the mediastinum. Scanning electron microscopy showed spherical formations corresponding in size to the particles counted using the Coulter counter. CONCLUSIONS:During the past decade attention has focused on microembolism in cardiac surgery, and this study has helped define the problem. Different strategies, such as eliminating the use of shed mediastinal blood or purifying the blood by different techniques, may improve the results of cardiac surgery in the future.
PURPOSE:This article describes an ex vivo method to recondition and transplant rejected donor lungs.DESCRIPTION:A 19-year-old man was brain dead after a traffic accident. A roentgenogram showed bilateral lung contusion. He had ongoing intratracheal bleeding. After optimizing ventilator treatment and suctioning the airways, PaO2 was 9 kPa (67.5 mm Hg) on FiO2 = 0.7. The lungs were rejected by all transplantation centers in the Nordic countries. We harvested the lungs for research. The right lung was severely injured. The left lung was edematous with bleeding spots in the lower lobe, and the mediobasal segment was atelectatic. The left lung was reconditioned ex vivo and kept in topical extracorporeal membrane oxygenation until it was transplanted into a 70-year-old man with chronic obstructive pulmonary disease 17 hours later.EVALUATION:The transplanted lung functioned very well, and the patient recovered uneventfully. At 3 months control, a computed tomographic thoracic scan and transbronchial biopsies showed a normal left lung, and the patient was in very good clinical condition, only to succumb to death from unrelated events 11 months after the transplantation.CONCLUSIONS:Rejected donor lungs may be successfully transplanted after being reconditioned ex vivo.
Shed blood is known to be a source of lipid micro-emboli in cardiac surgery. The aim of this study was to characterize the occurrence of these particles at different stages of the operation, and to study their occurrence in the circulation at multiple time-points after the retransfusion of shed blood. Forty-four patients undergoing routine surgery with cardiopulmonary bypass were included. Blood was sampled from the surgical field at different sampling locations during the operation. Shed blood was collected in a transfusion bag and retransfused. After which, blood was sampled from the arterial line of the heart-lung machine. A Coulter counter was used for particle determinion. The mean volume of shed blood collected was 340"215 ml. Particles in the size range 10–60 mm were found at varying concentrations, with the highest concentrations being found in blood collected after cannulation and from the pleura. After retransfusion of this blood, a biphasic response was seen in the blood drawn from the efferent line of the heart-lung machine. Particles are found in shed blood at all times during cardiac surgery, and when this blood was retransfused an increase was seen in particle concentration in the heart-lung machine.