Image plates (IPs), or phosphor storage screens, are a technology employed frequently in inertial confinement fusion (ICF) and high energy density plasma (HEDP) diagnostics because of their sensitivity to many types of radiation, including, x rays, protons, alphas, beta particles, and neutrons. Prior studies characterizing IPs are predicated on the signal level remaining below the scanner saturation threshold. Since the scanning process removes some signal from the IP via photostimulated luminescence, repeatedly scanning an IP can bring the signal level below the scanner saturation threshold. This process, in turn, raises concerns about the signal response of IPs after an arbitrary number of scans and whether such a process yields, for example, a constant ratio of signal between the nth and n + 1st scan. Here, the sensitivity of IPs is investigated when scanned multiple times. It is demonstrated that the ratio of signal decay is not a constant with the number of scans and that the signal decay depends on the x-ray energy. As such, repeatedly scanning an IP with a mixture of signal types (e.g., x ray, neutron, and protons) enables ICF and HEDP diagnostics employing IPs to better isolate a particular signal type.
Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below similar to 20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments. (c) 2024 Author(s).
Radiochromic film (RCF) and image plates (IPs) are both commonly used detectors in diagnostics fielded at inertial confinement fusion (ICF) and high-energy-density physics (HEDP) research facilities. Due to the intense x-ray background in all ICF/HEDP experiments, accurately calibrating the optical density of RCF as a function of x-ray dose, and the photostimulated luminescence per photon of IPs as a function of x-ray energy, is necessary for interpreting experimental results. Various measurements of the sensitivity curve of different IPs to x rays have been performed [Izumi et al., Proc. SPIE 8850, 885006 (2013) and Rosenberg et al., Rev. Sci. Instrum. 90(1), 013506 (2019)]; however, calibrating RCF is a tedious process that depends on factors such as the orientation in which the RCF is scanned in the film scanner and the batch of RCF used. These issues can be mitigated by cross-calibrating RCF with IPs to enable the use of IPs for the determination of dose on the RCF without scanning the RCF. Here, the first cross-calibration of RCF with IPs to quasi-monoenergetic titanium, copper, and molybdenum K-line x rays is presented. It is found that the IP-inferred dose rates on the RCF for the Ti and Mo x rays agree well with the measured dose rates, while the IP-inferred dose rate for the Cu x rays is larger than the measured dose rate by ∼2×. Explanations for this discrepancy and plans for future work are discussed.
CR-39 proton radiography is an experimental charged-particle backlighter platform fielded and used at OMEGA and the NIF to image electric and magnetic fields in a subject plasma. Processing a piece of CR-39 involves etching it in hot NaOH, and the etch time can greatly impact the background-to-signal ratio (BSR) in low-fluence (less than or similar to 4 x 10(4) cm(-2)) regions and detection efficiency in high-fluence regions (greater than or similar to 7 x 10(5) cm(-2)). For CR-39 data with high fluence variation, these effects mean that any single etch time will result in greater than or similar to 15% error in the measured signal in either the high- or low-fluence regions. This study aims to quantify the impact of the etch time on the BSR and efficiency losses and how these affect the field reconstruction. Experiments at the MIT Linear Electrostatic Ion Accelerator provided empirical values of the BSR and efficiency losses as a function of the fluence and etch time for fluences ranging from 3 x 10(3) to 7 x 10(5) cm(-2). Synthetic radiographs were generated with known fields and modulated based on empirical values of BSR and efficiency losses. The fields were reconstructed using a Monge-Amp & egrave;re code with the modulated radiographs as input. The results indicate that combining short and long etches allows for more accurate analysis of radiographs with high fluence variation, with the mean squared error of the reconstructed fields decreasing by factors of 1.2-7 compared to the reconstructions using only one etch time. (c) 2024 Author(s).
This paper reports on investigations on the impact of higher neutron fluences on the detection efficiency of protons with CR-39, a charged particle track detector. CR-39 is widely used as a diagnostic for inertial fusion applications and is an integral component of numerous particle diagnostics at the OMEGA laser facility and National Ignition Facility. As experiments continue to produce higher and higher yields, existing diagnostics are impacted by higher particle fluences than they were originally designed for. This paper presents data from experiments measuring proton signal on pieces of CR-39 with different levels of neutron fluence with two different etch times. The experiments show a decrease in signal recovery with increased neutron fluence, which is exacerbated at longer etch times. At 3 h etch time, data suggest a 17% ± 7% signal loss at 1.3 × 105 neutron-induced tracks per cm2 and a 67% ± 21% loss at 6 h etch time. Careful signal isolation techniques can recover most of the proton tracks even with moderate neutron fluence.