An overview is presented of the progress since 2021 in the construction and scientific programme preparation of the Divertor Tokamak Test (DTT) facility. Licensing for building construction has been granted at the end of 2021. Licensing for Cat. A radiologic source has been also granted in 2022. The construction of the toroidal field magnet system is progressing. The prototype of the 170 GHz gyrotron has been produced and it is now under test on the FALCON facility. The design of the vacuum vessel, the poloidal field coils and the civil infrastructures has been completed. The shape of the first DTT divertor has been agreed with EUROfusion to test different plasma and exhaust scenarios: single null, double null, X-divertor and negative triangularity plasmas. A detailed research plan is being elaborated with the involvement of the EUROfusion laboratories.
SPIDER, hosted at the Neutral Beam Test Facility (NBTF) in Padova, Italy, is the full scale prototype for the ITER Heating Neutral Beam (HNB) source. Another smaller compact RF ion source, NIO1, hosted by Consorzio RFX, was built to study the production and acceleration of H- ions in continuous operation. Both machines operate with the evaporation of caesium in order to enhance the production of negative ions. A collisional radiative model for caesium -hydrogen plasmas was recently developed. When used in conjunction with measurements from Optical Emission Spectroscopy, Laser Absorption Spectroscopy and electrostatic probes, the model can provide estimates of the plasma parameters with a good spatial resolution thanks to the many lines of sight available. This work presents a characterization of the plasma in SPIDER and NIO1 using this method. In particular, we investigate the influence of the RF power and the magnetic filter field on the plasma properties, and compare the results with those of other source and beam diagnostics.
The RFX-mod2 device, the upgraded version of the previous RFX-mod with a modified magnetic boundary, is presently under realization and will start to be operated in 2025. Significant upgrades of the diagnostic capabilities have been proposed and are under development. These include a largely increased number of in-vessel magnetic and electrostatic sensors, a new fast reciprocating manipulator for the exploration of the edge plasma in a wide range of experimental conditions, the improved Thomson scattering and soft x-ray diagnostics system for a detailed determination of the behavior of the electron temperature profile, new dedicated systems for the space and time resolved analysis of x-ray spectra and neutron rate, a reflectometric diagnostic for real-time determination of plasma position, two diagnostics devoted to the imaging of light impurities and influxes behavior along with arrays of halo current sensors. These diagnostic upgrades will be accompanied by a significant effort to improve the control of the electron density and of the impurity influxes by means of proper treatment of plasma facing components with in-vessel fixed electrodes distributed over the first wall. The described advancements will allow a deeper understanding of physics phenomena in the wide variety of magnetic configurations, including the tokamak, the reversed-field pinch and the Ultra-low q, which can be produced in RFX-mod2 thanks to its flexibility and unique MHD control capabilities.
One of the requirements of Heating and current drive Neutral Beam injectors for ITER is a beam homogeneity greater than 90%, to achieve an optimal beam transmission while keeping the heat load consistently low on the acceleration electrodes. The large size and complexity of ITER negative ion source play a key role in determining the homogeneity of the negative ion current of each of the 1280 beamlets and their divergence, and it is studied in the full-scale prototype source SPIDER. In this work the plasma properties are studied by spectroscopic and electrostatic measurements in the drivers, where the plasma is generated, and in the expansion region, where the plasma drifts and negative ions are produced, and they are correlated with the properties of the beam. The non-homogeneous plasma density profile is related to the non-homogeneous availability of negative ions along the beam vertical profile, with and without cesium evaporation. Visible tomography, a technique capable of characterizing isolated beamlet properties, is used to study the beam’s dependence on plasma uniformity along the entire beam profile. Using these tools, it has been demonstrated how an increase in plasma density is linked to an improvement in beam homogeneity. The latter has been directly correlated with plasma homogeneity. The magnetic filter field and biases of the plasma grid and bias plate are responsible for the variation in plasma density and its homogeneity. Non-uniformities in the plasma’s top/bottom and left/right distributions have been studied and partially addressed experimentally. The first issue was resolved by adjusting the radio-frequency power supplied to the plasma in different vertical regions, while the second issue was addressed by reversing the direction of the magnetic filter field and increasing the plasma density.
The RFX-mod2 installation is planned to be completed by 2024 and the start of operations is expected in 2025. The high flexibility of the machine (already tested in the previous RFX-mod experiment) allows operation in Reversed Field Pinch and tokamak configuration as well as ultra-low q pulses. In this work we present predictive analysis on transport, performances and plasma control in RFX-mod2 in view of the first experimental campaigns.
The experimental fusion reactor ITER will feature two (or three) heating neutral beam injectors (NBI) capable of delivering 33(or 50) MW of power into the plasma. A NBI consists of a plasma source for production of negative ions (extracted negative ion current up to 329 A/m 2 in H and 285 A/m 2 in D) then accelerated up to 1 MeV for one hour. The negative ion beam is neutralized, and the residual ions are electrostatically removed before injection. The beamline was designed for a beam divergence between 3 and 7 mrad. The ion source in ITER NBIs relies on RF-driven, Inductively-Coupled Plasmas (ICP), based on the prototypes developed at IPP Garching; RF-driven negative-ion beam sources have never been employed in fusion devices up to now. The recent results of SPIDER, the full size ITER NBI ion source operating at NBTF in Consorzio RFX, Padova, measure a beamlet divergence minimum of 12mrad and highlighted beam spatial non-uniformity. SPIDER results confirmed the experimental divergence found in smaller prototype sources, which is larger compared to filament-arc ion sources. Although prototype experiments have shown that the extracted current requirement can be achieved with minor design improvements, the beamlet divergence is expected to marginally achieve the design value of 7 mrad, which in multi-grid long accelerators results in unexpected heat loads over the accelerator grids. A contributor to the beam divergence is the energy/temperature of the extracted negative ions, so it is believed that plasma differences between the two source types play a role. Research is focused on the plasma parameters in the ion source. One RF driver, identical to the ones used in SPIDER, installed in a relatively small-scale experimental set-up, inherently more flexible than large devices, is starting operations devoted to the investigation of the properties of RF-generated plasmas, so as to contribute to the assessment of negative ion precursors, and of their relationship with the plasma parameters, particularly when enhancing plasma confinement. The scientific questions, that have arisen from the preliminary results of SPIDER, guided the design of the test stand, which are described in this contribution, together with the diagnostic systems and related simulation tools. The test stand, which shares with the larger experiment all the geometrical features and constraints, will allow technological developments and optimized engineering solutions related to the ICP design for the ITER NBIs.
SPIDER is the prototype ion source of MITICA, the full-size neutral beam heating system conceived for the ITER tokamak. It includes eight drivers to heat and sustain the inductively coupled plasma (ICP). Owing to their near cylindrical symmetry, the coupling between the radio-frequency (RF) active currents and the source plasma is studied using a 2D electromagnetic approach with simplified expressions for the plasma electrical conductivity taken from the literature. The power absorbed by the plasma and the effect of the induced plasma currents in lowering the inductance of the driver are based on data from the dedicated S16 experimental campaign (y.~2020) of SPIDER: plasma electron densities on the order of $10^{18}$ m$^{-3}$, electron temperatures $\sim 10$ eV; neutral gas pressure $\sim 0.3$ Pa and up to $50$ kW of net power per driver. It is found that the plasma conductivity cannot be explained by the friction forces associated to local collisional processes alone. The inclusion of an effective collisionality associated to non-local processes seems also insufficient to explain the experimental information. Only when the electrical conductivity is reduced where the RF magnetic field is more intense, can the heating power and driver inductance be acceptably reproduced. We present the first 2D electromagnetic ICP calculations in SPIDER for two types of plasma, without and with the addition of a static magnetic field. The power transfer efficiency to the plasma of the first drivers of SPIDER, in view of these models, is around 50%
ITER envisages the use of two heating neutral beam injectors plus an optional one as part of the auxiliary heating and current drive system. The 16.5 MW expected neutral beam power per injector is several notches higher than worldwide existing facilities. A Neutral Beam Test Facility (NBTF) was established at Consorzio RFX, exploiting the synergy of two test beds, SPIDER and MITICA. SPIDER is dedicated to developing and characterizing large efficient negative ion sources at relevant parameters in ITER-like conditions: source and accelerator located in the same vacuum where the beam propagates, immunity to electromagnetic interferences of multiple radio-frequency (RF) antennas, avoidance of RF-induced discharges on the outside of the source. Three years of experiments on SPIDER have addressed to the necessary design modifications to enable full performances. The source is presently under a long shut-down phase to incorporate learnings from the experimental campaign. Parallelly, developments on MITICA, the full-scale prototype of the ITER NBI featuring a 1 MV accelerator and ion neutralization, are underway including manufacturing of in-vessel components, while power supplies and auxiliary plants are already under final testing and commissioning. Integration, commissioning and tests of the 1MV power supplies are essential for this first-of-kind system, unparalleled both in research and industry field. The integrated test to confirm 1MV output by combining invertor systems, DC generators and transmission lines extracted errors/accidents in some components. To realize a concrete system for ITER, solutions for the repair and the improvement of the system were developed. Hence, NBTF is emerging as a necessary facility, due to the large gap with existing injectors, effectively dedicated to identify issues and find solutions to enable successful ITER NBI operations in a time bound fashion.
A roto-vibrational resolved corona model is discussed for the simulation of the Fulcher spectrum in Hydrogen low pressure discharges. The model allows to derive H 2 rotational and vibrational temperatures from the analysis of emission spectra in the [600:640] nm range. The model is applied to the analysis of emission spectra collected at the SPIDER negative ion source. Results are presented for different values of the applied power to the plasma, pressure, and for different regions of the plasma, thus providing a characterization of the plasma with respect to the internal temperatures of the molecular component.
SPIDER is the full-scale prototype of the ion source of the ITER Heating Neutral Beam Injector, where negative ions of Hydrogen or Deuterium are produced by a RF generated plasma and accelerated with a set of grids up to ~100 keV. The Power Supply System is composed of high voltage dc power supplies capable of handling frequent grid breakdowns, high current dc generators for the magnetic filter field and RF generators for the plasma generation. During the first 3 years of SPIDER operation different electrical issues were discovered, understood and addressed thanks to deep analyses of the experimental results supported by modelling activities. The paper gives an overview on the observed phenomena and relevant analyses to understand them, on the effectiveness of the short-term modifications provided to SPIDER to face the encountered issues and on the design principle of long-term solutions to be introduced during the currently ongoing long shutdown.
Consorzio RFX and INFN-LNL have designed, built and operated the compact radiofrequency negative ion source NIO1 (Negative Ion Optimization phase 1) with the aim of studying the production and acceleration of H - ions. In particular, NIO1 was designed to keep plasma generation and beam extraction continuously active for several hours. Since 2020 the production of negative ions at the plasma grid (the first grid of the acceleration system) has been enhanced by a Cs layer, deposited though active Cs evaporation in the source volume. For the negative ion sources applied to fusion neutral beam injectors, it is essential to keep the beam current and the fraction of co-extracted electrons stable for at least 1 h, against the consequences of Cs sputtering and redistribution operated by the plasma. The paper presents the latest results of the NIO1 source, in terms of caesiation process and beam performances during continuous (6 ÷ 7 h) plasma pulses. Due to the small dimensions of the NIO1 source (20 cm×∅10 cm), the Cs density in the volume is high (10 15 ÷ 10 16 m -3 ) and dominated by plasma-wall interaction. The maximum beam current density and minimum fraction of co-extracted electrons were respectively about 30 A/m 2 and 2. Similarly to what done in other negative ion sources, the plasma grid temperature in NIO1 was raised for the first time, up to 80 °C, although this led to a minimal improvement of the beam current and to an increase of the co-extracted electron current.
The SPIDER test facility is the full-size ITER neutral beam injector (NBI) ion source, required to provide 355 A/m2 extracted negative ion current density in hydrogen (285 A/m2 in deuterium) with an electron-to-ion ratio lower than 0.5 (one in deuterium). The negative ion source is attached to a three-grids extraction and acceleration system. The operational conditions for the cases presented in this work involve short pulses (up to about 30 s length) repeated every five to six minutes. The duty cycle can be adjusted. In order to fulfil the requirement on the extracted negative ion current with reduced amount of co-extracted electrons, the evaporation of caesium into the ion source through Cs ovens (three in SPIDER) and the optimisation of Cs conditioning techniques are mandatory. At SPIDER, the plasma is monitored via optical emission spectroscopy techniques measuring the plasma emission in a line-of-sight (LOS) integrated manner in several positions inside the ion source. In particular, close to the extraction region, two sets (centred at 5 mm and at 35 mm distance from the plasma grid) of four horizontal LOSs are used to retrieve the vertical profile of the plasma emission. During the Cs conditioning campaign performed at SPIDER, although the extraction capabilities were reduced due to technical problems, the RF power coupled to the plasma reached 400 kW with all four RF generators working simultaneously. The negative ions produced by surface emission affects the plasma radiation, and the ion source performances in terms of extracted negative ions and co-extracted electrons. The aim of this work is to study the evolution of the plasma emission over the initial phase of the Cs conditioning campaign. The effect of Cs conditioning on the extracted negative ions and electrons is also presented and discussed.
SPIDER (source for the production of ions of deuterium extracted from RF plasma) is the full-scale prototype of the ITER neutral beam injector ion source. The plasma heating takes place inside eight drivers via inductive coupling, through the radiofrequency (RF) coil. To achieve optimum conditions during source operation it is necessary to know the plasma behavior under various operational conditions. One of the essential parameters is the plasma electron density. It is possible to experimentally measure this parameter and, currently, different methods are being explored, such as the estimations coming from a Langmuir probe and optical emission spectroscopy. However, these methods are either available for temporary measurements or require dedicated analyses with large uncertainties. In this regard, alternative, reliable, and fast diagnostic tools will be beneficial for the estimation of the order of magnitude of electron density inside the driver. Two models for the estimation of electron density are recalled, discussed, and further modified in this work: one is based on the classical power balance equation, and the other is recently described in the literature and relies on classical plasma conductivity. Both models use equivalent electrical parameters of the driver derived from available electrical measurements at the output of the RF generator and through the knowledge of the matching network and the transmission line length. This work explicitly focuses on the application of these models to estimate the plasma electron density in a single driver of SPIDER. Furthermore, the estimations are compared with the first experimental results obtained from temporary electrostatic probe measurements and are found to be in good agreement in terms of magnitude and trends.
Three years of experiments on SPIDER allowed characterization of the main features of the source plasma and of the negative ion beam, in the original design configuration. For the large dimensions of the source chamber, and of the extraction area, the investigation of the single-beamlet currents and of the source plasma uniformity had to be carried out to extend the knowledge gained in smaller prototype sources. The configuration of the multiple RF drivers and filter field topologies were found to cause a peculiar behavior in the plasma confinement in the drivers, creating left-right asymmetries which were also visible in the extracted negative ion currents, even after the early implementation of a new scheme of plasma-grid current send and return busbars that greatly improved performance at high filter fields. The plasma properties in the driver and expansion region as well as the positive ion energy at the extraction region were studied in different experimental conditions, and interpreted also with the support of numerical models, suggesting that an improved plasma confinement could contribute to the increase of the plasma density, and to a certain extent to a lowering of the plasma potential profile; both effects shall contribute to increase the presence of cold negative ions for the formation of low-divergence beamlets. Early results related to unwanted RF discharges on the back of the plasma source and the gas conductance of the beam source suggested the reduction of the vessel pressure as mitigation, leading to the definition of a new pumping system. The difficulties related to the simultaneous operation, stable control and high-power operation of multiple RF self-oscillating vacuum tube based RF generators were an unambiguous obstruction to the experimentation, calling for the implementation of RF solid-state amplifiers. The initial tests related to caesium management, the non-uniform plasma properties at different locations across the plasma grid, and the challenges in the measurement of the current and divergence of the accelerated beamlet, unambiguously resulted in the need of new diagnostic systems to investigate with better resolution the spatial uniformities. This contribution summarises how the main experimental findings in the previous experimental campaigns are driving modifications to the SPIDER experiment, during the present shut down, in view of future operations.
An overview of the recent operations and the main results of cesium injection in the Source for the Production of Ions of Deuterium Extracted from Rf plasma (SPIDER) negative ion source are described in this contribution. In experiments without cesium injection, all SPIDER plants were tested to verify the basic expectations on the operational parameters (e.g., electron cooling effectiveness of magnetic filter field) and to determine its operational region. For beam properties, it was shown that the current density varies across the beam in the vertical direction. In preliminary cesium experiments, the expected increase of negative ion current and simultaneous decrease of co-extracted electrons were found, along with the influence of the control parameters (polarization of the plasma electrodes, magnetic filter field) on the SPIDER beam uniformity in the horizontal and vertical directions. It was shown that non-Gaussian tails can be identified in the angular distribution on the plane perpendicular to the beam propagation direction. Stray particles, nonhomogeneous beam and large divergence might result in unexpected heat and particle loads over ITER neutral beam injector (NBI) accelerator grids; it is the goal of SPIDER to assess and possibly to identify suitable methods for controlling these beam features. A major shutdown, planned for late 2021, to solve the issues identified during the operation and to carry out scheduled modifications, is outlined. Such improvements are expected to allow SPIDER to pursue the ITER requirements in terms of negative ion current, electron-to-ion ratio, and beam duration.
Giant negative ion sources for neutral beam injectors deliver huge negative ion currents, thanks to their multi-beamlet configuration. As the single-beamlet optics defines the transmission losses along the beamline, the extraction of a similar current for all beamlets is extremely desirable, in order to facilitate the beam source operation (i.e., around perveance match). This Review investigates the correlation between the vertical profile of beam intensity and the vertical profiles of plasma properties at the extraction region of the source, focusing on the influence of increasing cesium injection. Only by the combined use of all available source diagnostics, described in this Review, can beam features on the scale of the non-uniformities be investigated with a sufficient space resolution. At RF power of 50 kW/driver, with intermediate bias currents and a filter field of 2.4 mT, it is found that the central part of the four vertical beam segments exhibits comparable plasma density and beamlet currents; at the edges of the central segments, both the beam and electron density appear to decrease (probably maintaining fixed electron-to-ion ratio); at the bottom of the source, an increase of cesium injection can compensate for the vertical drifts that cause a much higher presence of electrons and a lower amount of negative ions.
The results are presented of an experimental activity performed in the RFX-mod device aimed at characterizing plasma dynamics in the so-called Ultralow-q (ULq) magnetic configuration, which corresponds to edge safety factor values below 1. The role of the edge safety factor in determining plasma dynamics is studied. In particular, a characterization of MHD activity is performed. The results of dedicated non-linear 3D visco-resistive MHD simulations are in good quantitative agreement with the experimental observations. In particular, the predicted tendency for ULq plasmas to be characterized by magnetic spectra dominated by a single mode (either a kink or a double resonant internal mode) is confirmed by experiment. Magnetic reconnection plays a relevant role in determining the dynamics of the magnetic topology. Both almost quiescent and largely fluctuating plasmas are observed with a strong sensitivity on the edge safety factor. The main MHD properties of the ULq are compared to those of RFP and tokamak discharges, also produced in the RFX-mod device. MHD modes exhibit toroidal rotation at a frequency depending on mode amplitude. Differently from what encountered in RFP plasmas at comparable current levels, no wall locking is detected.
The negative-ion based neutral beam injector for heating and current drive of the ITER plasma (ITER HNB) is under development, at present focusing on the optimization of the full-scale plasma source in the SPIDER test stand. The production of H − or D − ions in the ion source is based on the low work function surfaces obtained by caesium evaporation. This paper describes the caesium conditioning procedure and the corresponding beam performances during the first operation of SPIDER with caesium. Technical solutions to overcome present limitations of the test stand are described. The influence of source parameters on the caesium effectiveness was investigated in short beam pulse operation; with total radio-frequency (RF) power of 400 kW and filling pressure below 0.4 Pa, and a limited number of extraction apertures, a negative ion current density of about 200 A m −2 was extracted in hydrogen, with beam energy lower than 60 keV. Beam optics and beam uniformity were assessed thanks to the acceleration of isolated ion beamlets. A possible procedure to accelerate a uniform beam was demonstrated at low RF power. The results obtained in this first investigation provided key indications on the operation of one of the largest existing sources of accelerated negative hydrogen-like ions.
Since the 2018 IAEA FEC Conference, FTU operations have been devoted to several experiments covering a large range of topics, from the investigation of the behaviour of a liquid tin limiter to the runaway electrons mitigation and control and to the stabilization of tearing modes by electron cyclotron heating and by pellet injection. Other experiments have involved the spectroscopy of heavy metal ions, the electron density peaking in helium doped plasmas, the electron cyclotron assisted start-up and the electron temperature measurements in high temperature plasmas. The effectiveness of the laser induced breakdown spectroscopy system has been demonstrated and the new capabilities of the runaway electron imaging spectrometry system for in-flight runaways studies have been explored. Finally, a high resolution saddle coil array for MHD analysis and UV and SXR diamond detectors have been successfully tested on different plasma scenarios.
SPIDER is the full scale prototype for the ITER Heating Neutral Beam (HNB) source. The production of negative ions in the source mostly relies on the conversion of H/D atoms and positive ions on a 1.6 m $\times0.8$ m converter surface, which is covered with cesium in order to reduce its work function and maximize the conversion efficiency. In SPIDER, optical emission spectroscopy (OES) is used to study the light emitted by the plasma. In particular, the intensities of the cesium emission lines are tracked and used to reconstruct the distribution of its excited states. By coupling these measurements with a collisional radiative (CR) model, estimates of the cesium ground-state density and plasma parameters can be obtained in various parts of the source which are unreachable by other diagnostics. This work describes such a model and its use in conjunction with OES during the first operation with cesium in SPIDER. The electron density at the bottom of the source was found to be much larger than the rest, as a consequence of vertical drifts caused by the horizontal filter field, which would likely indicate a lower negative-ion availability for the beam. The effect of increasing the cesium evaporation rate on the negative-ion and electron densities was also investigated.