We present the design and development of a novel, compact integrated on-chip spectrometer operating at millimeter (mm) and submillimeter (sub-mm) wavelengths. The Superconducting Waveguide Integrated Submillimeter Spectrometer (SWISS) promises significant improvements in spectral resolution, optical efficiency, and frequency coverage over current mm-wave spectrometers by using a free-space rectangular waveguide architecture. Light is coupled in through the antenna front end, which separates the two polarizations and passes them to the waveguide spectrometer through a contactless metamaterial transition. Each waveguide spectrometer consists of a feedline coupled to a series of filters based on single-pole cavity resonators with varying resonant frequencies. To maximize packing density, the filter banks are oriented out of the focal plane, and an E-plane bend in the output from the cavity filters enables a planar and scalable construction. The output of each filter is coupled to a kinetic inductance detector (KID) to enable high multiplexing factors. The spectrometer is fabricated using stacks of silicon wafers etched with a deep reactive-ion etch (DRIE) and metallized. In these proceedings, we discuss current development on a SWISS prototype including measurements on a prototype antenna front end contactless transition and fabrication a prototype waveguide spectrometer.
Historically employed spectroscopic architectures used for large field of view mapping spectroscopy in millimetere and sub-millimetre astronomy suffer from significant drawbacks. On-chip filterbank spectrometers are a promising technology in this respect; however, they must overcome an orders-of-magnitude increase in detector counts, efficiency loss due to dielectric properties, and stringent fabrication tolerances that currently limit scaling to resolutions of order 1000 over a large array. We propose coupling a medium-resolution Fourier transform spectrometer to a low-resolution filterbank spectrometer focal plane, which serves as a post-dispersion element. In this arrangement, medium resolution imaging spectroscopy is provided by the Fourier transform spectrometer, while the low resolution filterbank spectrometer serves to decrease the photon noise inherent in typical broadband Fourier transform spectrometer measurements by over an order of magnitude. This is achieved while maintaining the excellent imaging advantages of both architectures. We present predicted mapping speeds for a filterbank-dispersed Fourier transform spectrometer from a ground-based site and a balloon-borne platform. We also demonstrate the potential that an instrument of this type has for an R~1000 line intensity mapping experiment using the James Clerk Maxwell Telescope as an example platform. We demonstrate that a filterbank-dispersed Fourier transform spectrometer would be capable of R~1000 measurements of CO power spectra with a signal-to-noise ratio of 10--100 with surveys of $10^5$--$10^6$ spectrometer hours.
This work focuses on the development and demonstration of tunable superconducting on-chip resonator, leveraging the intrinsic current-dependent non-linear kinetic inductance of superconducting aluminium, and investigating the effect of oxygen content. Thin films are deposited using standard metal evaporation. We present results from a comprehensive study based on a series of evaporated Al thin films. This research aims to inform and constrain optimisation strategies for the design of mm-wave on-chip spectrometers, particularly regarding yield, resolution, and efficiency. By systematically varying film stoichiometry, we use a series of DC measurements to extract fundamental film properties such as resistivity, critical current and critical temperature. Furthermore, we employ low-loss DC-coupled microwave resonators to characterise both their microwave properties and the non-linear kinetic inductance, comparing these findings to a determined non-linear kinetic model. Finally, we discuss the possibility of usage in a parametric amplifier.
Superconducting thin films with high intrinsic kinetic inductance (L)k are important for high-sensitivity detectors, enabling strong coupling in hybrid quantum systems and enhancing nonlinearities in quantum devices. We report the room-temperature reactive sputtering of titanium nitride thin films with a critical temperature T-c of 3.8 K and a thickness of 27 nm at a slow sputtering rate of 0.9 nm/min. Fabricated into resonators, these films exhibit a sheet kinetic inductance Lk,square of 394 pH/square, as inferred from resonant frequency measurements. This high Lk,square is consistent with the measured short coherence length of a disordered superconductor. X-ray diffraction analysis and EDS spectra confirm the formation of stoichiometric TiN, with no residual unreacted titanium. The films also demonstrate a characteristic sheet resistance of 1163 Omega/square, yielding an impedance that is an order of magnitude higher than conventional 50 Omega resonators and hence a higher resonance voltage required for strong coupling in quantum systems. This property could enhance microwave single-photon coupling strength by an order of magnitude, offering transformative potential for hybrid quantum systems and quantum sensing. Furthermore, the high Lk enables Kerr nonlinearities comparable to state-of-the-art quantum devices. Combined with its relatively high T, this thin film presents a promising platform for superconducting devices, including amplifiers and qubits capable of operating at elevated temperatures.
The SuperSpec-MUSCAT Collaboration (SuMAC) is an effort to operate SuperSpec spectrometers in the MUSCAT instrument at the Large Millimeter Telescope (LMT). SuperSpec is an on-chip filterbank spectrometer using kinetic inductance detectors (KIDs), with moderate R∼ 200 spectral resolution for observing in the 1 mm atmospheric window (190-300 GHz). While nominally a continuum camera operating a 1.1 mm, MUSCAT was also designed to operate as a testbed for pioneering detection technologies. In July 2025, three SuperSpec devices were installed and commissioned in the MUSCAT cryostat with minimal modifications to the system. This work presents an overview of SuperSpec's deployment and performance in MUSCAT along with the main results from the Summer 2025 observation campaign. Highlights include the detection of CO emission line in the galaxy NGC253, mapping the Orion KL region, and preliminary line intensity mapping scans.
SPT-3G+ is the next-generation camera for the South Pole Telescope (SPT). SPT is designed to measure the cosmic microwave background (CMB) and the mm/sub-mm sky. The planned focal plane consists of 34,000 microwave kinetic inductance detectors (MKIDs), divided among three observing bands centered at 220, 285, and 345 GHz. Each readout line is designed to measure 800 MKIDs over a 500 MHz bandwidth, which places stringent constraints on the accuracy of the frequency placement required to limit resonator collisions that reduce the overall detector yield. To meet this constraint, we are developing a two-step process that first optically maps the resonance to a physical pixel location, and then next trims the interdigitated capacitor (IDC) to adjust the resonator frequency. We present a cryogenic LED apparatus operable at 300 mK for the optical illumination of SPT-3G+ detector arrays. We demonstrate integration of the LED controls with the GHz readout electronics (RF-ICE) to take data on an array of prototype SPT-3G+ detectors. We show that this technique is useful for characterizing defects in the resonator frequency across the detector array and will allow for improvements in the detector yield.
We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This portable, integrated system can steer the beam over a $\sim$3 cm $\times$ 3 cm area on the surface of any sensor with a precision of $\sim$100 $\mu$m, enabling characterization of device response as a function of position. This fills a critical need in the landscape of calibration tools for sub-Kelvin devices, including those used for dark matter detection and quantum computing. These communities have a shared goal of understanding the impact of ionizing radiation on device performance, which can be pursued with our system. This paper describes the design of the first-generation calibration system and the results from successfully testing its performance at room temperature and 20 mK.
Large multiplexing factors are a primary advantage of kinetic inductance detectors (KIDs), but the implementation of high density arrays still presents significant challenges. Deviations between designed and achieved resonant frequencies are common, and differential loading and responsivity variation across an array may lead to dynamic inter-resonator interactions. It is therefore valuable to be able to both set and maintain the resonant frequency of a KID in situ, using the readout system. We show that it is possible to alter the resonant frequency of the devices by multiple linewidths through the application of readout current, and establish a new stable operational bias point at the driven frequency by making use of the hysteretic bistability commonly seen as bifurcation in frequency-domain measurements. We examine this interaction using a readout tone at fixed frequency positioned near or within the unbiased resonant bandwidth. Development of a control methodology based on this principle remains in an early stage, but a foundational step is understanding the interaction of the readout current with the resonator, in particular its influence on the resonant frequency. In this work, we study conventional KIDs with no physical isolation from the substrate, so we posit that the readout current primarily interacts with the resonator via non-thermal mechanisms, resulting in a predominantly reactive response. This behaviour is reproduced by a simple lumped-element circuit model of the resonance and readout system, providing a straightforward framework for analysis and interpretation. This demonstration is an important early step in the development of techniques which seek to dynamically alter the resonant frequencies of conventional KID arrays, and sets the stage for fast active resonant frequency control under operational conditions.
The testing and quality assurance of cryogenic superconducting detectors is a time- and labor-intensive process. As experiments deploy increasingly larger arrays of detectors, new methods are needed for performing this testing quickly. Here, we propose a process for flagging under-performing detector wafers before they are ever tested cryogenically. Detectors are imaged under an optical microscope, and computer vision techniques are used to analyze the images, searching for visual defects and other predictors of poor performance. Pipeline performance is verified via a suite of images with simulated defects, yielding a detection accuracy of 98.6%. Lastly, results from running the pipeline on prototype microwave kinetic inductance detectors from the planned SPT-3G+ experiment are presented.
SCUBA-2([1])/POL-2([2]) has been the most productive instrument at JCMT since it's fully commissioned([3]) in 2011 September, and it's constantly oversubscribed during the call-for-proposals by a factor of 3 to 5. The proposed new 850 mu m instrument will feature 7272 state-of-the-art Microwave Kinetic Inductance Detectors (MKIDs)([4]) operated below 100 mK, fully utilizing the JCMT's 12 arcmin Field of View (FoV), thus have all the capabilities of SCUBA-2 at 850 mu m, yet will map an order of magnitude faster. The new instrument will be incorporated with intrinsic polarization measurement capability which is 3636 pixels. Mapping the 850 mu m polarization will be improved by a factor of at least 20.
RF-ICE is a signal processing platform for the readout of large arrays of superconducting resonators. Designed for flexibility, the system's low digital latency and ability to independently and dynamically set the frequency and amplitude of probe tones in real time has enabled previously-inaccessible views of resonator behaviour, and opened the door to novel resonator control schemes. We introduce a multi-frequency imaging technique, developed with RF-ICE, which allows simultaneous observation of the entire resonance bandwidth. We demonstrate the use of this technique in the examination of the response of superconducting resonators to variations in applied readout current and thermal loading. We observe that, used in conjunction with a conventional frequency sweep at sufficiently large amplitude to induce resonance bifurcation, the multi-frequency imaging technique reveals a resonator response which is not captured by the frequency sweep measurement alone. We demonstrate that equivalent resonant frequency shifts can be achieved using either thermal, optical, or readout loading, and use this equivalence to counteract a change in thermal loading by digitally modulating the readout current through a resonator. We develop and implement a proof-of-concept closed-loop negative electro-quasiparticle feedback algorithm which first sets and then maintains the resonant frequency of a lumped element kinetic inductance detector while the loading on it is varied. Although this simple implementation is not yet suitable to deploy at scale, it demonstrates the utility of this feedback technique to improve linearity while addressing amplifier distortion, resonator response non-uniformity, and crosstalk. It can be applied to kinetic inductors in non-bolometric operation, and sets the stage for future developments.
Far-infrared (FIR) wavelength light provides a wealth of information about astrophysical processes. Large field-of-view FIR spectrometers face a variety of challenges that can be bypassed by utilizing on-chip filter bank technology. To this end, we have been developing microwave kinetic inductance detectors (MKIDs) to couple to on-chip spectrometric technologies. We utilize a unique two-silicon wafer design to create a waveguide for an on-chip spectrometer between 1.4 and 2 THz. The spectrometer’s principle of operation is electromagnetic radiation traveling down a center waveguide before being picked off by a resonance cavity and absorbed by a detector. The MKIDs are designed to couple directly to the waveguide using an annular antenna shape for the inductor. Alignment of the two-wafer design is achieved with two dowel pins and a hole and slot pattern in our custom designed box. We present the design and early test data from a 18-channel prototype device. The prototype yielded the full 18 resonances with quality factors Q_c of about 5 × 10^4 and Q_i of about 1 × 10^4 . We plan to use the technology we developed to create an n × n pixel device targeting R=100 .
The Mexico-UK Submillimeter Camera for AsTronomy (MUSCAT) is a continuum camera in the 1.1-mm band for the Large Millimeter Telescope (LMT), with 1458 lumped-element kinetic inductance detectors distributed across six arrays. Installed on the telescope at the end of 2021, we present the characterization of the detector beams of four of the six arrays based on the beam map observations of bright point sources developed during the first commissioning campaign between February and June 2022. With all the observations, we estimate the average positions of each detector with an average error in azimuth of less than 0.70 arcsec and less than 1.05 arcsec in elevation. From the positions, we created the coadded maps of all the detectors, from which we selected only eight observations to calculate the mean beam width of MUSCAT-LMT, of 6.32 +/- 0.36 arcsec x5.78 +/- 0.19 arcsec. By stacking the maps, we identify the sidelobes with three main structures whose amplitudes are similar to 3% with respect to the main beam.
In this Roadmap, we present a vision for the future of submillimetre and millimetre astronomy in the United Kingdom over the next decade and beyond. This Roadmap has been developed in response to the recommendation of the Astronomy Advisory Panel (AAP) of the STFC in the AAP Astronomy Roadmap 2022. In order to develop our stragetic priorities and recommendations, we surveyed the UK submillimetre and millimetre community to determine their key priorities for both the near-term and long-term future of the field. We further performed detailed reviews of UK leadership in submillimetre/millimetre science and instrumentation. Our key strategic priorities are as follows: 1. The UK must be a key partner in the forthcoming AtLAST telescope, for which it is essential that the UK remains a key partner in the JCMT in the intermediate term. 2. The UK must maintain, and if possible enhance, access to ALMA and aim to lead parts of instrument development for ALMA2040. Our strategic priorities complement one another: AtLAST (a 50m single-dish telescope) and an upgraded ALMA (a large configurable interferometric array) would be in synergy, not competition, with one another. Both have identified and are working towards the same overarching science goals, and both are required in order to fully address these goals.
Traditional technologies for far-infrared (FIR) spectroscopy generally involve bulky dispersive optics. Integrated filter bank spectrometers promise more compact designs, but implementations using superconducting transmission line networks become lossy at terahertz frequencies. We describe a novel on-chip spectrometer architecture designed to extend this range. A filter bank spectrometer is implemented using vacuum waveguide etched into a silicon wafer stack. A single trunk line feeds an array of resonant cavities, each coupled to a kinetic inductance detector fabricated on an adjacent wafer. We discuss the design and fabrication of a prototype implementation, initial test results at ambient temperature, and prospects for future development.
We present a design and implementation of a frequency-tunable superconducting resonator. The resonance frequency tunability is achieved by flux-coupling a superconducting LC loop to a current-biased feedline; the resulting screening current leads to a change of the kinetic inductance and shift in the resonance frequency. The thin-film aluminum resonator consists of an interdigitated capacitor and thin line inductors forming a closed superconducting loop. The magnetic flux from the nearby niobium current feedline induces Meissner shielding currents in the resonator loop leading to a change in the kinetic part of the total inductance of the resonator. We demonstrate continuous frequency tuning within 160 MHz around the resonant frequency of 2.7 GHz. We show that: (1) frequency up-conversion is achieved when a kilohertz ac modulation signal is superimposed onto the dc bias resulting in sidebands to the resonator tone; (2) three-wave mixing is attained by parametrically pumping the nonlinear kinetic inductance using a strong rf pump signal in the feedline. The simple architecture is amenable to large-array multiplexing and on-chip integration with other circuit components. The concept could be applied in flux magnetometers, up-converters, and parametric amplifiers operating above 4 K when alternative high-critical-temperature material with high kinetic inductance is used.
We present an updated design of the 220 GHz microwave kinetic inductance detector (MKID) pixel for SPT-3G+, the next-generation camera for the South Pole Telescope. We show results of the dark testing of a 63-pixel array with mean inductor quality factor $Q_{i} = 4.8 \times 10^{5}$, aluminum inductor transition temperature $T_{c} = 1.19$ K, and kinetic inductance fraction $\alpha _{k} = 0.32$. We optically characterize both the microstrip-coupled and CPW-coupled resonators, and find both have a spectral response close to prediction with an optical efficiency of $\eta \sim 70\%$. However, we find slightly lower optical response on the lower edge of the band than predicted, with neighboring dark detectors showing more response in this region, though at level consistent with less than 5% frequency shift relative to the optical detectors. The detectors show polarized response consistent with expectations, with a cross-polar response of $\sim 10\%$ for both detector orientations.