Ultra-high dose rate radiotherapy (UHDR) has shown promise in reducing normal tissue damage (the so-called FLASH effect) compared to conventional dose-rate irradiation (CDR), while maintaining tumor control. However, the spatiotemporal dynamics underlying this effect remain incompletely characterized in vivo, particularly in studies relying on endpoint or sparsely sampled measurements. In this study, we used optical coherence tomography (OCT) to perform dense longitudinal imaging of epidermal and microvascular responses following single-fraction irradiation of mouse thighs with CDR and UHDR. OCT enabled simultaneous, non-invasive quantification of epidermal thickness and vascular volume density (VVD), with histological correlation. At 20 Gy, CDR induced a transient increase in VVD, followed by a reduction and incomplete recovery, whereas UHDR produced a more controlled response, with stabilization near baseline by week 25. At 30 Gy, CDR resulted in a marked reduction in angiographic signal, with partial recovery, whereas UHDR showed a more gradual decline followed by a restoration toward baseline. At both doses, UHDR vascular density remained significantly higher than CDR at late time points. Epidermal responses paralleled vascular dynamics: UHDR-treated skin demonstrated thicker and more organized epidermis at day 10 and greater long-term preservation. Histology confirmed improved structural integrity under UHDR compared to CDR. These results demonstrate that OCT enables longitudinal, in vivo characterization of coupled epithelial and microvascular responses to radiation and reveal distinct modality-dependent response trajectories. By capturing both structural and functional dynamics in the same tissue over time, this approach provides insight not accessible through endpoint analyses. The findings support a role for vascular dynamics in normal tissue sparing associated with UHDR irradiation and highlight OCT as a translational tool for monitoring radiation-induced tissue response.
Additive manufacturing ( AM) has revolutionized component design for liquid rocket engines by offering rapid manufacturing capabilities. This has led to significant opportunities for development and flight programs in the propulsion industry, resulting in cost and schedule savings, as well as performance improvements through new designs and alloy development. A noteworthy example is the GRX-810 oxide dispersion strengthened (ODS) alloy, which was specifically developed for extreme temperatures. This Ni-Co-Cr based alloy was created using integrated computational materials engineering (ICME) techniques to focus on a new class of materials with exceptional temperature and oxidation-resistant properties. The GRX-810 alloy utilizes AM processes to incorporate nano-scale yttria particles throughout its microstructure, resulting in remarkable enhancements. Compared to traditional Nickel-based superalloys, the GRX-810 alloy offers a twofold increase in tensile strength, 1,000-fold better creep properties, and two-fold improvement in oxidation resistance. NASA successfully demonstrated the development and manufacturing of components using the GRX-810 alloy through laser powder bed fusion (L-PBF) and laser powder directed energy deposition (LP-DED) processes. Extensive efforts were made to model, evaluate metallurgical properties, develop heat treatment processes, characterize the microstructure, and determine mechanical properties. The GRX-810 alloy was specifically designed for aerospace applications, including liquid rocket engine injectors, preburners, turbines, and hot-section components, capable of withstanding temperatures up to 1,100 degrees C. The objective of this alloy development is to bridge the temperature gap between traditional Nickel-based superalloys and refractory alloys. This paper provides a comprehensive comparison of the GRX-810 alloy with other aerospace alloys, discussing its microstructure, mechanical properties, processing advancements, component development, and hot-fire testing results. The ultimate goal of this development was to elevate the Technology Readiness Level (TRL) of the GRX-810 alloy, enabling its integration into NASA and commercial aerospace applications.
BackgroundWhile careful planning and pre-treatment checks are performed to ensure patient safety during external beam radiation therapy (EBRT), inevitable daily variations mean that in vivo dosimetry (IVD) is the only way to attain the true delivered dose. Several countries outside the US require daily IVD for quality assurance. However, elsewhere, the manual labor and time considerations of traditional in vivo dosimeters may be preventing frequent use of IVD in the clinic.PurposeThis study expands upon previous research using plastic scintillator discs for optical dosimetry for electron therapy treatments. We present the characterization of scintillator discs for in vivo x-ray dosimetry and describe additional considerations due to geometric complexities.MethodsPlastic scintillator discs were coated with reflective white paint on all sides but the front surface. An anti-reflective, matte coating was applied to the transparent face to minimize specular reflection. A time-gated iCMOS camera imaged the discs under various irradiation conditions. In post-processing, background-subtracted images of the scintillators were fit with Gaussian-convolved ellipses to extract several parameters, including integral output, and observation angle.ResultsDose linearity and x-ray energy independence were observed, consistent with ideal characteristics for a dosimeter. Dose measurements exhibited less than 5% variation for incident beam angles between 0 degrees and 75 degrees at the anterior surface and 0-60 circle$<^>\circ $ at the posterior surface for exit beam dosimetry. Varying the angle between the disc surface and the camera lens did not impact the integral output for the same dose up to 55 degrees. Past this point, up to 75 degrees, there is a sharp falloff in response; however, a correction can be used based on the detected width of the disc. The reproducibility of the integral output for a single disc is 2%, and combined with variations from the gantry angle, we report the accuracy of the proposed scintillator disc dosimeters as +/- 5.4%.ConclusionsPlastic scintillator discs have characteristics that are well-suited for in vivo optical dosimetry for x-ray radiotherapy treatments. Unlike typical point dosimeters, there is no inherent readout time delay, and an optical recording of the measurement is saved after treatment for future reference. While several factors influence the integral output for the same dose, they have been quantified here and may be corrected in post-processing.
Background and purpose: Cardiac implanted electronic devices (CIED) require dose monitoring during each fraction of radiotherapy, which can be time consuming and may have delayed read-out times. This study explores the potential of Cherenkov imaging combined with scintillation dosimetry as an alternative verification system. Methods and materials: Time-gated, complementary metal-oxide-semiconductor (iCMOS) cameras were used to collect video images of anthropomorphic phantoms and patients undergoing radiation treatment near chest wall cardiac devices. Scintillator discs and optically stimulated luminescence dosimeters (OSLDs) were used for dose measurement. Accuracy of spatial delivery was assessed by overlaying predicted surface dose outlines derived from the treatment planning system (TPS) with the Cherenkov images. Dose measurements from OSLDs and scintillators were compared. Results: In phantom studies, Cherenkov images visibly indicated when dose was delivered to the CIED as compared to non-overlapping dose deliveries. Comparison with dose overlays revealed congruence at the planned position and non-congruence when the phantom was shifted from the initial position. Absolute doses derived from scintillator discs aligned well with the OSLD measurements and TPS predictions for three different positions, measuring within 10 % for in-field positions and within 5 % for out-of-field positions. For two patients with CIEDs imaged over 18 fractions, Cherenkov imaging confirmed positional accuracy for all fractions, and dose measured by scintillator discs deviated by <0.015 Gy from the OSLD measurements. Conclusions: Cherenkov imaging combined with scintillation dosimetry presents an alternative methodology for CIED monitoring with the added benefit of instantly detecting deviations, enabling timely corrective actions or proper patient triage.
Purpose:In our experience treating locally advanced pancreatic cancer with magnetic resonance-guided radiation therapy (MRgRT), the true-fast imaging with steady-state free precession sequences used to generate both the real-time 2-dimensional (2D) magnetic resonance images (MRI; 2D cine) and the pretreatment high-resolution 3-dimensional (3D) MRI impart differing intensities for relevant structures between the 2 scans. Since these variations can confound target tracking selection, we propose that an understanding of the differing contrast profiles could improve selection of tracking structures. Methods and Materials:We retrospectively reviewed both 2D cine and 3D MRI images for 20 patients with pancreatic cancer treated with MRgRT. At simulation, an appropriate tracking target was identified and contoured on a single 3-mm sagittal slice of the 3D MRI. This sagittal slice was directly compared with the coregistered 7-mm 2D cine to identify structures with notable discrepancies in signal intensity. The 3D MRI was then explored in additional planes to confirm structure identities. For quantitative verification of the clinically observed differences, the pixel intensity distributions of 2D cine and 3D MRI digital imaging and communications in medicine data sets were statistically compared. Results:In all patients reviewed, arteries (aorta, celiac, superior mesenteric artery, hepatic artery) appeared mildly hyperintense on both scans. However, veins (portal vein, superior mesenteric vein) appeared hyperintense on 2D cine but isointense on 3D MRI. Biliary structures appeared mildly hyperintense on 2D cine but starkly hyperintense on 3D MRI. The pixel intensity distributions extracted from 2D cine and 3D MRI images were confirmed to differ significantly (2 sample Kolmogorov-Smirnov test; test statistic, 0.40; P < .001). Conclusions:There are significant variations in image intensity between the immediate pretreatment 2D cine compared with the initial planning 3D MRI. Understanding variations of image intensity between the different MRI sequences used in MRgRT is valuable to radiation oncologists and may lead to improved target tracking and optimized treatment delivery.
PURPOSE:Electron paramagnetic resonance (EPR) biodosimetry, used to triage large numbers of individuals incidentally exposed to unknown doses of ionizing radiation, is based on detecting a stable physical response in the body that is subject to quantifiable variation after exposure. In vivo measurement is essential to fully characterize the radiation response relevant to a living tooth measured in situ. The purpose of this study was to verify EPR spectroscopy in vivo by estimating the radiation dose received in participants' teeth. METHODS AND MATERIALS:A continuous wave L-band spectrometer was used for EPR measurements. Participants included healthy volunteers and patients undergoing head and neck and total body irradiation treatments. Healthy volunteers completed 1 measurement each, and patients underwent measurement before starting treatment and between subsequent fractions. Optically stimulated luminescent dosimeters and diodes were used to determine the dose delivered to the teeth to validate EPR measurements. RESULTS:Seventy measurements were acquired from 4 total body irradiation and 6 head and neck patients over 15 months. Patient data showed a linear increase of EPR signal with delivered dose across the dose range tested. A linear least-squares weighted fit of the data gave a statistically significant correlation between EPR signal and absorbed dose (P < .0001). The standard error of inverse prediction (SEIP), used to assess the usefulness of fits, was 1.92 Gy for the dose range most relevant for immediate triage (≤7 Gy). Correcting for natural background radiation based on patient age reduced the SEIP to 1.51 Gy. CONCLUSIONS:This study demonstrated the feasibility of using spectroscopic measurements from radiation therapy patients to validate in vivo EPR biodosimetry. The data illustrated a statistically significant correlation between the magnitude of EPR signals and absorbed dose. The SEIP of 1.51 Gy, obtained under clinical conditions, indicates the potential value of this technique in response to large radiation events.
Recent studies suggest ultra-high dose rate radiation treatment (UHDR-RT) reduces normal tissue damage compared to conventional radiation treatment (CONV-RT) at the same dose. In this study, we compared first, the kinetics and degree of skin damage in wild-type C57BL/6 mice, and second, tumor treatment efficacy in GL261 and B16F10 dermal tumor models, at the same UHDR-RT and CONV-RT doses. Flank skin of wild-type mice received UHDR-RT or CONV-RT at 25 Gy and 30 Gy. Normal skin damage was tracked by clinical observation to determine the time to moist desquamation, an endpoint which was verified by histopathology. Tumors were inoculated on the right flank of the mice, then received UHDR-RT or CONV-RT at 1 × 11 Gy, 1 × 15, 1 × 25, 3 × 6 and 3 × 8 Gy, and time to tumor tripling volume was determined. Tumors also received 1 × 11, 1 × 15, 3 × 6 and 3 × 8 Gy doses for assessment of CD8+/CD4+ tumor infiltrate and genetic expression 96 h postirradiation. All irradiations of the mouse tumor or flank skin were performed with megavoltage electron beams (10 MeV, 270 Gy/s for UHDR-RT and 9 MeV, 0.12 Gy/s for CONV-RT) delivered via a clinical linear accelerator. Tumor control was statistically equal for similar doses of UHDR-RT and CONV-RT in B16F10 and GL261 murine tumors. There were variable qualitative differences in genetic expression of immune and cell damage-associated pathways between UHDR and CONV irradiated B16F10 tumors. Compared to CONV-RT, UHDR-RT resulted in an increased latent period to skin desquamation after a single 25 Gy dose (7 days longer). Time to moist skin desquamation did not significantly differ between UHDR-RT and CONV-RT after a 30 Gy dose. The histomorphological characteristics of skin damage were similar for UHDR-RT and CONV-RT. These studies demonstrated similar tumor control responses for equivalent single and fractionated radiation doses, with variable difference in expression of tumor progression and immune related gene pathways. There was a modest UHDR-RT skin sparing effect after a 1 × 25 Gy dose but not after a 1 × 30 Gy dose.
Background: Use of a linear accelerator in ultra-high dose rate (UHDR) mode can provide a conduit for wider access to UHDR FLASH effects, sparing normal tissue, but care needs to be taken in the use of such systems to ensure errors are minimized. Purpose: Failure Modes and Effects Analysis (FMEA) was carried out in a team that has been involved in converting a LINAC between clinical use and UHDR experimental mode for more than one year, following the proposed methods of TG100. Methods: A team of 9 professionals with extensive experience were polled to outline the process map and workflow for analysis, and developed fault trees for potential errors, as well as failure modes that would results. The team scored the categories of severity magnitude (S), occurrence likelihood (O), and detectability potential (D) in a scale of 1 to 10, so that a risk priority number (RPN=S*O*D) could be assessed for each. Results: A total of 46 potential failure modes were identified, including 5 with RPN>100. These failure modes involved 1) patient set up, 2) gating mechanisms in delivery, and 3) detector in the beam stop mechanism. Identified methods to mitigate errors included 1) use of a checklist post conversion, 2) use of robust radiation detectors, 3) automation of QA and beam consistency checks, and 4) implementation of surface guidance during beam delivery. Conclusions: The FMEA process was considered critically important in this setting of a new use of a LINAC, and the expert team developed a higher level of confidence in the ability to safely move UHDR LINAC use towards expanded research access.
Objective. Existing ultra-high dose rate (UHDR) electron sources lack dose rate independent dosimeters and a calibrated dose control system for accurate delivery. In this study, we aim to develop a custom single-pulse dose monitoring and a real-time dose-based control system for a FLASH enabled clinical linear accelerator (Linac). Approach. A commercially available point scintillator detector was coupled to a gated integrating amplifier and a real-time controller for dose monitoring and feedback control loop. The controller was programmed to integrate dose for each radiation pulse and stop the radiation beam when the prescribed dose was delivered. Additionally, the scintillator was mounted in a solid water phantom and placed underneath mice skin for in vivo dose monitoring. The scintillator was characterized in terms of its radiation stability, mean dose-rate ( D ̇ m ), and dose per pulse ( D p ) dependence. Main results. The D p exhibited a consistent ramp-up period across ∼4–5 pulse. The plastic scintillator was shown to be linear with D ̇ m (40–380 Gy s −1 ) and D p (0.3–1.3 Gy Pulse −1 ) to within +/− 3%. However, the plastic scintillator was subject to significant radiation damage (16%/kGy) for the initial 1 kGy and would need to be calibrated frequently. Pulse-counting control was accurately implemented with one-to-one correspondence between the intended and the actual delivered pulses. The dose-based control was sufficient to gate on any pulse of the Linac. In vivo dosimetry monitoring with a 1 cm circular cut-out revealed that during the ramp-up period, the average D p was ∼0.045 ± 0.004 Gy Pulse −1 , whereas after the ramp-up it stabilized at 0.65 ± 0.01 Gy Pulse −1 . Significance. The tools presented in this study can be used to determine the beam parameter space pertinent to the FLASH effect. Additionally, this study is the first instance of real-time dose-based control for a modified Linac at ultra-high dose rates, which provides insight into the tool required for future clinical translation of FLASH-RT.
Introduction/Background: The goal of Total Skin Electron Therapy (TSET) is to achieve a uniform surface dose, although assessment of this is never really done and typically limited points are sampled. A computational treatment simulation approach was developed to estimate dose distributions over the body surface, to compare uniformity of (i) the 6 pose Stanford technique and (ii) the rotational technique. Methods: The relative angular dose distributions from electron beam irradiation was calculated by Monte Carlo simulation for cylinders with a range of diameters, approximating body part curvatures. These were used to project dose onto a 3D body model of the TSET patient's skin surfaces. Computer animation methods were used to accumulate the dose values, for display and analysis of the homogeneity of cover-age. Results: The rotational technique provided more uniform coverage than the Stanford technique. Anomalies of under dose were observed in lateral abdominal regions, above the shoulders and in the perineum. The Stanford technique had larger areas of low dose laterally. In the rotational technique, 90% of the patient's skin was within +/- 10% of the prescribed dose, while this percentage decreased to 60% or 85% for the Stanford technique, varying with patient body mass. Interestingly, the highest discrepancy was most apparent in high body mass patients, which can be attributed to the loss of tangent dose at low angles of curvature. Discussion/Conclusion: This simulation and visualization approach is a practical means to analyze TSET dose, requiring only optical sur-face body topography scans. Under-and over-exposed body regions can be found, and irradiation could be customized to each patient. Dose Area Histogram (DAH) distribution analysis showed the rota-tional technique to have better uniformity, with most areas within 10% of the umbilicus value. Future use of this approach to analyze dose coverage is possible as a routine planning tool.
Purpose Electron paramagnetic resonance oximetry using the OxyChip as an implantable oxygen sensor can directly and repeatedly measure tissue oxygen levels. A phase I, first-in-human clinical study has established the safety and feasibility of using OxyChip for reliable and repeated measurements of oxygen levels in a variety of tumors and treatment regimens. A limitation in these studies is the inability to easily locate and identify the implanted probes in the tissue, particularly in the long term, thus limiting spatial/anatomical registration of the implant for proper interpretation of the oxygen data. In this study, we have developed and evaluated an enhanced oxygen-sensing probe embedded with gold nanoparticles (GNP), called the OxyChip-GNP, to enable visualization of the sensor using routine clinical imaging modalities. Methods In vitro characterization, imaging, and histopathology studies were carried out using tissue phantoms, excised tissues, and in vivo animal models (mice and rats). Results The results demonstrated a substantial enhancement of ultrasound and CT contrast using the OxyChip-GNP without compromising its electron paramagnetic resonance and oxygen-sensing properties or biocompatibility. Conclusions The OxyChips embedded with gold nanoparticles (OxyChip-GNP) can be readily identified in soft tissues using standard clinical imaging modalities such as CT, cone beam-CT, or ultrasound imaging while maintaining its capability to make repeated in vivo measurements of tissue oxygen levels over the long term. This unique capability of the OxyChip-GNP facilitates precisely localized in vivo oxygen measurements in the clinical setting.
PURPOSE:Cherenkov imaging is clinically available as a radiation therapy treatment verification tool. The aim of this work was to discover the benefits of always-on Cherenkov imaging as a novel incident detection and quality improvement system through review of all imaging at our center. METHODS AND MATERIALS:Multicamera Cherenkov imaging systems were permanently installed in 3 treatment bunkers, imaging continuously over a year. Images were acquired as part of normal treatment procedures and reviewed for potential treatment delivery anomalies. RESULTS:In total, 622 unique patients were evaluated for this study. We identified 9 patients with treatment anomalies occurring over their course of treatment, which were only detected with Cherenkov imaging. Categorizing each event indicated issues arising in simulation, planning, pretreatment review, and treatment delivery, and none of the incidents were detected before this review by conventional measures. The incidents identified in this study included dose to unintended areas in planning, dose to unintended areas due to positioning at treatment, and nonideal bolus placement during setup. CONCLUSIONS:Cherenkov imaging was shown to provide a unique method of detecting radiation therapy incidents that would have otherwise gone undetected. Although none of the events detected in this study reached the threshold of reporting, they identified opportunities for practice improvement and demonstrated added value of Cherenkov imaging in quality assurance programs.
The delivery of radiation at an ultra-high dose rate (FLASH) is an important new approach to radiotherapy (RT) that appears to be able to improve the therapeutic ratio by diminishing damage to normal tissues. While the mechanisms by which FLASH improves outcomes have not been established, a role involving molecular oxygen (O2) is frequently mentioned. In order to effectively determine if the protective effect of FLASH RT occurs via a differential direct depletion of O2 (compared to conventional radiation), it is essential to consider the known role of O2 in modifying the response of cells and tissues to ionising radiation (known as 'the oxygen effect'). Considerations include: (1) The pertinent reaction involves an unstable intermediate of radiation-damaged DNA, which either undergoes chemical repair to restore the DNA or reacts with O2, resulting in an unrepairable lesion in the DNA, (2) These reactions occur in the nuclear DNA, which can be used to estimate the distance needed for O2 to diffuse through the cell to reach the intermediates, (3) The longest lifetime that the reactive site of the DNA is available to react with O2 is 1-10 μsec, (4) Using these lifetime estimates and known diffusion rates in different cell media, the maximal distance that O2 could travel in the cytosol to reach the site of the DNA (i.e., the nucleus) in time to react are 60-185 nm. This calculation defines the volume of oxygen that is pertinent for the direct oxygen effect, (5) Therefore, direct measurements of oxygen to determine if FLASH RT operates through differential radiochemical depletion of oxygen will require the ability to measure oxygen selectively in a sphere of <200 nm, with a time resolution of the duration of the delivery of FLASH, (6) It also is possible that alterations of oxygen levels by FLASH could occur more indirectly by affecting oxygen-dependent cell signalling and/or cellular repair.
541 Background: MR-guided stereotactic body radiation therapy (MR-SBRT) is a novel method of treating mobile tumors with soft-tissue gating and on-table adaptive planning. In our experience using the ViewRay MRIdian system (VR) for treating locally advanced pancreatic cancer (PA) with MR-SBRT, the true-fast imaging with steady-state free precession (TRUFI) sequences on the VR impart differing intensities for relevant structures seen on the pre-treatment high resolution 3D MRI (3D MRI) versus the real-time 2D cine MRI (2D cine) used for target tracking. Since these variations can confound target tracking selection, we propose that an understanding of the differing contrast profiles could improve selection of tracking structures and optimize treatment delivery. Methods: We retrospectively reviewed both 3D MRI and 2D cine images for patients (pts) with PA (n =20) treated on the VR. At simulation, an appropriate tracking target was identified and contoured on a single 3mm sagittal slice of the 3D MRI. This sagittal slice was directly compared to the registered 7mm 2D cine to identify structures with notable discrepancies in signal intensity. The 3D MRI was then explored in additional planes to confirm structure identities. For quantitative verification of the clinically observed differences, the pixel intensity distributions of 3D MRI and 2D cine DICOM image datasets were statistically compared. Results: In all pts reviewed, arteries (aorta, celiac, SMA) appeared with similar contrast profiles on both images. However, veins (portal vein, SMV) appeared hypointense on 3D MRI but hyperintense on 2D cine. Biliary structures appeared hyperintense on 3D MRI but only mildly hyperintense on 2D cine. The pixel intensity distributions extracted from 3D MRI and 2D cine images were confirmed to differ significantly (two sample Kolmogorov-Smirnov test; test statistic =0.40; p < 0.001). Conclusions: There are significant variations in image intensity between the initial treatment planning 3D MRI and the immediate pre-treatment 2D cine obtained with the VR. Understanding these discrepancies can guide radiation oncologists in choosing optimal tracking targets. Future work will focus on identifying the particular causes and frequencies of target tracking failures and exploring alternative tracking algorithms using artificial intelligence which could ultimately allow for VMAT on the ViewRay system.
Purpose/Objective(s)Although human papillomavirus (HPV)-associated squamous cell carcinomas of the oropharynx (SCCOP) have high locoregional control rates, understanding spatial patterns of recurrence remains important in the IMRT era. A standardized methodology, using deformable registration, has been proposed to more accurately assess recurrent disease volumes in the context of initial treatment dose distributions. In this study we used this methodology to analyze recurrent malignancies in HPV-associated SCCOP.Materials/MethodsA single institution database was retrospectively assessed for p16 (+) SCCOP treated with curative intent, either definitively or adjuvantly, using IMRT. Recurrence required either pathologic confirmation or clinically conclusive imaging. The earliest image indicative of recurrence was identified (either CT, MRI or PET-CT) and a "recurrent GTV" (rGTV) was contoured. Local and regional recurrences in the same patient were analyzed separately. This image was deformed onto the initial CT simulation, and the deformed rGTV was categorized into five types (A-E). In Types A/B the rGTV centroid was inside the prescribed high dose distribution, and delineated "A" if the dose to 95% of the failure volume (fD95%) was ≥ 95%, versus "B" if < 95%. In Types C/D the rGTV centroid was inside the elective dose distribution, and delineated "C" if fD95% was ≥ 95%, versus "D" if < 95%. In Type E the rGTV centroid was outside the elective and high dose volume. All deformable registrations were performed using MIM treatment planning software.ResultsA total of 140 patients met inclusion criteria, of which 114 were treated definitively and 26 were treated adjuvantly. 17 locoregional recurrences in 16 patients were identified; 8 failed at the primary, 7 failed regionally, and 1 failed both at the primary and regionally. Recurrence was confirmed by pathology in 14 patients. Five patients were AJCC 8th Stage I, three were Stage II, and eight were Stage III. The mean rGTV was 9.2 cc (0.1 to 60.7). Of the 17 recurrences, 11 (65%) were Type A, two (12%) were Type B, one (6%) was Type C, and three (18%) were Type E. The only Type C recurrence occurred in a patient treated on the radiotherapy alone arm on NRG HN002 within the 48 Gy elective nodal volume. Type E failures occurred in level VI-A in a Stage II base of tongue malignancy, the contralateral neck in a patient treated ipsilaterally for a Stage I tonsillar malignancy, and the base of skull in a Stage III tonsillar malignancy.ConclusionIn HPV-associated SCCOP locoregional recurrences occur primarily within the high dose volume, indicating a need for improved stratification and potential intensification in a small subset of patients. Deformable registration-based patterns of failure analysis are feasible, and should be the standard reporting methodology.
PURPOSE:Increased oxygen levels may enhance the radiosensitivity of brain metastases treated with stereotactic radiosurgery (SRS). This project administered hyperbaric oxygen (HBO) prior to SRS to assess feasibility, safety, and response. METHODS:38 patients were studied, 19 with 25 brain metastases treated with HBO prior to SRS, and 19 historical controls with 27 metastases, matched for histology, GPA, resection status, and lesion size. Outcomes included time from HBO to SRS, quality-of-life (QOL) measures, local control, distant (brain) metastases, radionecrosis, and overall survival. RESULTS:The average time from HBO chamber to SRS beam-on was 8.3 ± 1.7 minutes. Solicited adverse events (AEs) were comparable between HBO and control patients; no grade III or IV serious AEs were observed. Radionecrosis-free survival (RNFS), radionecrosis-free survival before whole-brain radiation therapy (WBRT) (RNBWFS), local recurrence-free survival before WBRT (LRBWFS), distant recurrence-free survival before WBRT (DRBWFS), and overall survival (OS) were not significantly different for HBO patients and controls on Kaplan-Meier analysis, though at 1-year estimated survival rates trended in favor of SRS + HBO: RNFS - 83% vs 60%; RNBWFS - 78% vs 60%; LRBWFS - 95% vs 78%; DRBWFS - 61% vs 57%; and OS - 73% vs 56%. Multivariate Cox models indicated no significant association between HBO treatment and hazards of RN, local or distant recurrence, or mortality; however, these did show statistically significant associations (p < 0.05) for: local recurrence with higher volume, radionecrosis with tumor resection, overall survival with resection, and overall survival with higher GPA. CONCLUSION:Addition of HBO to SRS for brain metastases is feasible without evident decrement in radiation necrosis and other clinical outcomes.