Objective.Achieving FLASH dose rate with pencil beam scanning intensity modulated proton therapy is challenging. However, utilizing a single energy layer with a ridge filter (RF) can maintain dose rate and conformality. Yet, changes in patient anatomy over the treatment course can render the RF obsolete. Unfortunately, creating a new RF is time-consuming, thus, incompatible with online adaptation. To address this, we propose to re-optimize the spot weights while keeping the same initial RF.Approach.Data from six head and neck cancer patients with a repeated computed tomography (CT2) were used. FLASH treatment plans were generated with three methods on CT2: 'full-adaptation' (FA), optimized from scratch with a new RF; 'spot-adaptation only' (SAO), re-using initial RF but adjusting plan spot weights; and 'no adaptation' (NoA) where the dose from initial plans on initial CT (CT1) was recomputed on CT2. The prescribed dose per fraction was 9 Gy. Different beam angles were tested for each CT2(1 beam per fraction). The FA, SAO and NoA plans were then compared on CT2.Main results.Fractions with SAO showed a median decrease of 0.05 Gy forD98% and a median increase of 0.03 Gy forD2% of CTV when compared to their homologous FA plans on nominal case. Median conformity number decreased by 0.03. Median max dose to spinal cord increased by 0.09 Gy. The largest median increase in mean dose to organs was 0.03 Gy to the mandible. The largest observed median difference in organs receiving a minimal dose rate of 40 Gy s-1was 0.5% for the mandible. Up to 16 of the 20 evaluated SAO fractions were thus deemed clinically acceptable, with up to 8 NoA plans already acceptable before adaptation.Significance.Proposed SAO workflow showed that for most of our evaluated plans, daily reprinting of RF was not necessary.
Background and Purpose: Proton arc therapy (PAT) is an emerging modality delivering continuously rotating proton beams. Current PAT planning approaches are time-consuming, making them unsuitable for online adaptation. This study proposes an accelerated workflow for adapting PAT plans. Materials and Methods: The proposed workflow transfers spots from initial computed tomography (CT) to the CT of the day, updates energy layers considering the initial pattern, and re-optimizes selected transferred spots based on their initial weights and impact on the objective function.A retrospective study was conducted on five head and neck patients who underwent plan adaptation on a repeated CT. PAT plans were generated with two different methods on the repeated CT: reference, created de novo, and smart-adapted, generated with the proposed adaptive workflow. Robust optimization was performed for all plans. Results: Smart-adapted plans achieved similar mean dose to organs at risk as the reference: the largest median increase of mean dose was 1.9 Gy to the mandible; the median of maximum dose to spinal cord was 0.5 Gy lower for the smart-adapted plans. The median target coverage, i.e. D98, to primary tumor and nodes of smart-adapted plans decreased by 0.2 and 0.4 Gy for the nominal case, and 0.4 and 0.6 Gy for the worst-case scenario; all smart-adapted plans met clinical objectives. The smart-adaptation method reduced average planning time from 19184 s to 5626 s, a 3.4-fold improvement. Conclusions: Smart-adapted plans achieve similar plan quality to the reference method, while significantly reducing plan generation time for new patient anatomy.
•Corrections of auto-segmented volumes are not all dosimetrically relevant.•Relevance of corrections for auto-segmented volumes can be predicted.•Slice-wise corrections with relevance indicator can preserve the plan quality.•Slice-wise corrections with such indicator can decrease the number of corrections.
Purpose: Ethos proposes a template-based automatic dose planning (Etb) for online adaptive radiotherapy. This study evaluates the general performance of Etb for prostate cancer, as well as the ability to generate patient -optimal plans, by comparing it with another state-of-the-art automatic planning method, i.e., deep learning dose prediction followed by dose mimicking (DP + DM).Materials: General performances and capability to produce patient-optimal plan were investigated through two studies: Study-S1 generated plans for 45 patients using our initial Ethos clinical goals template (EG_init), and compared them to manually generated plans (MG). For study-S2, 10 patients which showed poor performances at study-S1 were selected. S2 compared the quality of plans generated with four different methods: 1) Ethos initial template (EG_init_se-lected), 2) Ethos updated template-based on S1 results (EG_upd_selected), 3) DP + DM, and 4) MG plans.Results: EG_init plans showed satisfactory performance for dose level above 50 Gy: reported mean metrics dif-ferences (EG_init minus MG) never exceeded 0.6 %. However, lower dose levels showed loosely optimized metrics, mean differences for V30Gy to rectum and V20Gy to anal canal were of 6.6 % and 13.0 %. EG_i-nit_selected showed amplified differences in V30Gy to rectum and V20Gy to anal canal: 8.5 % and 16.9 %, respectively. These dropped to 5.7 % and 11.5 % for EG_upd_selected plans but strongly increased V60Gy to rectum for 2 patients. DP + DM plans achieved differences of 3.4 % and 4.6 % without compromising any V60Gy. Conclusion: General performances of Etb were satisfactory. However, optimizing with template of goals might be limiting for some complex cases. Over our test patients, DP + DM outperformed the Etb approach.