COVID-19 is caused by SARS-CoV-2 infection and was initially discovered in Wuhan. This outbreak quickly spread all over China and then to more than 20 other countries. SARS-CoV-2 fluorescent microsphere immunochromatographic test strips were prepared by the combination of time-resolved fluorescence immunoassay with a lateral flow assay. The analytical performance and clinical evaluation of this testing method was done and the clinical significance of the testing method was verified. The LLOD of SARS-CoV-2 antibody IgG and IgM was 0.121U/L and 0.366U/L. The specificity of IgM and IgG strips in healthy people and in patients with non-COVID-19 disease was 94%, 96.72% and 95.50%, 99.49%, respectively; and sensitivity of IgM and IgG strips for patients during treatment and follow-up was 63.02%, 37.61% and 87.28%, 90.17%, respectively. The SARS-CoV-2 antibody test strip can provide rapid, flexible and accurate testing, and is able to meet the clinical requirement for rapid on-site testing of virus. The ability to detect IgM and IgG provided a significant benefit for the detection and prediction of clinical course with COVID-19 patients.
BACKGROUND:The ongoing coronavirus disease 19 (COVID-19) is posing a threat to the public health globally. Serological test for SARS-CoV-2 antibody can improve early diagnosis of COVID-19 and serves as a valuable supplement to RNA detection.METHOD:A SARS-CoV-2 IgG/IgM combined antibody test strip based on colloidal gold immunochromatography assay was developed, with both spike protein and nucleocapsid protein of SARS-CoV-2 antigen used for antibody detection. From 3 medical institutions across China, serum or plasma of 170 patients with confirmed COVID-19 diagnosis and 300 normal controls were collected and tested with the strip. Sensitivity, specificity, kappa coefficient, receiver operating characteristic (ROC) curve, and area under the curve (AUC) were analyzed. Positive rates in different medical centers, age group, gender, and different disease course were compared.RESULTS:158 out 170 samples from confirmed COVID-19 patients had positive results from the test, and 296 out of 300 samples from normal controls had negative results. The kit was 92.9% sensitive and 98.7% specific. The positive rate was 77.3% during the first week after disease onset, but reached 100% since day 9. AUC and kappa coefficient were 0.958 and 0.926, respectively, which showed the consistency of the test results with the standard diagnosis. Age or gender caused little variations in the kit sensitivity.CONCLUSION:The rapid, easy-to-use SARS-CoV-2 IgG/IgM combined antibody test kit has a superior performance, which can help with accurate diagnosis and thus timely treatment and isolation of COVID-19 patients, that contributes to the better control of the global pandemic.