The rise of biosimilar monoclonal antibodies has renewed the interest in monoclonal antibody (mAb) charge variants composition and separation. The sample displacement chromatography (SDC) has the potential to overcome the low separation efficiency and productivity associated with bind-elute separation of mAb charge variants. SDC in combination with weak cation exchanging macroporous monolithic chromatographic column was successfully implemented for a separation of charge variants and aggregates of monoclonal IgG under overloading conditions. The charge variants composition was at-line monitored by a newly developed, simple and fast analytical method, based on weak cation exchange chromatography. It was proven that basic charge variants acted as displacers of IgG molecules with lower pI, when the loading was performed 1 to 1.5 pH unit below the pI of acidic charge variants. The efficiency of the SDC process is flow rate independent due to a convection-based mass transfer on the macroporous monolith. The productivity of the process at optimal conditions is 35 mg of purified IgG fraction per milliliters of monolithic support with 75-80% recovery. As such, an SDC approach surpasses the standard bind-elute separation in the productivity for a factor of 3, when performed on the same column. The applicability of the SDC approach was confirmed for porous particle-based column as well, but with 1.5 lower productivity compared to the monoliths.
Changes in protein glycosylation are related to different diseases and have a potential as diagnostic and prognostic disease biomarkers. Transferrin (Tf) glycosylation changes are common marker for congenital disorders of glycosylation. However, biological interindividual variability of Tf N-glycosylation and genes involved in glycosylation regulation are not known. Therefore, high-throughput Tf isolation method and large scale glycosylation studies are needed in order to address these questions. Due to their unique chromatographic properties, the use of chromatographic monoliths enables very fast analysis cycle, thus significantly increasing sample preparation throughput. Here, we are describing characterization of novel immunoaffinity-based monolithic columns in a 96-well plate format for specific high-throughput purification of human Tf from blood plasma. We optimized the isolation and glycan preparation procedure for subsequent ultra performance liquid chromatography (UPLC) analysis of Tf N-glycosylation and managed to increase the sensitivity for approximately three times compared to initial experimental conditions, with very good reproducibility.
We investigated effect of immobilization procedure and monolith structure on chromatographic performance of methacrylate monoliths bearing affinity ligands. Monoliths of different pore size and various affinity ligands were prepared and characterized using physical and chromatographic methods. When testing protein A monoliths with different protein A ligand densities, a significant nonlinear effect of ligand density on dynamic binding capacity (DBC) for IgG was obtained and accurately described by Langmuir isotherm curve enabling estimation of protein A utilization as a function of ligand density. Maximal IgG binding capacity was found to be at least 12 mg/mL exceeding theoretical monolayer adsorption value of 7.8 mg/mL assuming hexagonal packing and IgG hydrodynamic diameter of 11 nm. Observed discrepancy was explained by shrinkage of IgG during adsorption on protein A experimentally determined through calculated adsorbed IgG layer thickness of 5.4 nm from pressure drop data. For monoliths with different pore size maximal immobilized densities of protein A as well as IgG dynamic capacity linearly correlates with monolith surface area indicating constant ligand utilization. Finally, IgGs toward different plasma proteins were immobilized via the hydrazide coupling chemistry to provide oriented immobilization. DBC was found to be flow independent and was increasing with the size of bound protein. Despite DBC was lower than IgG capacity to immobilized protein A, ligand utilization was higher.
Affinity depletion of abundant proteins such as HSA is an important stage in routine sample preparation prior to MS/MS analysis of biological samples with high range of concentrations. Due to the charge competition effects in electrospray ion source that results in discrimination of the low-abundance species, as well as limited dynamic range of MS/MS, restricted typically by three orders of magnitude, the identification of low-abundance proteins becomes a challenge unless the sample is depleted from high-concentration compounds. This dictates a need for developing efficient separation technologies allowing fast and automated protein depletion. In this study, we performed evaluation of a novel immunoaffinity-based Convective Interaction Media analytical columns (CIMac) depletion column with specificity to HSA (CIMac-αHSA). Because of the convective flow-through channels, the polymethacrylate CIMac monoliths afford flow rate independent binding capacity and resolution that results in relatively short analysis time compared with traditional chromatographic supports. Seppro IgY14 depletion kit was used as a benchmark to control the results of depletion. Bottom-up proteomic approach followed by label-free quantitation using normalized spectral indexes were employed for protein quantification in G1/G2 and cleavage/blastocyst in vitro fertilization culture media widely utilized in clinics for embryo growth in vitro. The results revealed approximately equal HSA level of 100 ± 25% in albumin-enriched fractions relative to the nondepleted samples for both CIMac-αHSA column and Seppro kit. In the albumin-free fractions concentrated 5.5-fold by volume, serum albumin was identified at the levels of 5-30% and 20-30% for the CIMac-αHSA and Seppro IgY14 spin columns, respectively.