A 54-year-old male patient with bilateral metal-on-metal hip prosthesis and recently diagnosed cobalt toxicity presented with gradually worsening symptoms of heart failure. Serum cobalt (120 μg/l; normal <1 μg/l) and chromium (108.8 μg/l; normal <1.4 μg/l) levels were significantly elevated.