Cancer therapy studies using proton accelerators are underway in several major medical centers in the U.S., Russia, Japan and elsewhere. To facilitate dosimetry intercomparisons between these laboratories, alanine-based detectors produced at the National Institute of Standards and Technology and commercially available radiochromic films were studied for their possible use as passive transfer dosimeters for clinical proton beams. Evaluation of characteristics of these instruments, including the LET dependence of their response of proton energy, was carried out at the Institute of Theoretical and Experimental Physics. Results of absolute dose measurements were regarded as a preliminary step of dose intercomparison between ITEP and NIST. Measurements made in a number of experiments showed average agreement between the ITEP and NIST dosimetry standards to 2.5%.
On 11 December 1991, a radiation overexposure occurred at an industrial radiation facility in Maryland. The radiation source was a 3-MV potential drop accelerator designed to produce high electron beam currents for materials-processing applications. This accelerator is capable of producing a 25 milliampere swept electron beam that is scanned over a width of 112.5 cm and which emerges from the accelerator vacuum system through a titanium double window assembly. During maintenance on the lower window pressure plate, an operator placed his hands, head, and feet in the beam. This was done with the filament voltage of the electron source turned "off," but with the full accelerating potential on the high voltage terminal. The operator's body, especially his extremities and head, were exposed to electron dark current. In an attempt to reconstruct the accident, radiochromic film and alanine measurements were made with the accelerator operated at two beam currents. Measured dose rates ranged from approximately 40 cGy s-1 inside the victim's shoe to 1,300 cGy s-1 at the hand position. Approximately 3 mo after the accident, it was necessary to amputate the four digits of the victim's right hand and most of the four digits of his left hand. Electron paramagnetic resonance spectrometry, which measures the concentration of radiation-induced paramagnetic centers in calcified tissues, was used to estimate the dose to the victim's extremities. A mean dose estimate of 55.0 +/- 3.5 Gy (95% confidence level) averaged over the mass of the bone was obtained for the victim's left middle finger (middle phalanx).
A method of evaluating intense ionizing radiation fields remotely and in real-time has been developed, The system employs radiochromic sensors, materials that change color in a known fashion upon exposure to radiation, and a helium-neon laser/photodiode detector combination to measure the radiation-induced absorbance change at 632.8 nm. The sensor, placed at the point of interest in the radiation field, is probed by the laser to assess the absorbed dose at a given time as a function of any absorbance changes in the sensor. The resultant attenuation of the probe beam is registered by the photodiode and recorded and evaluated with a data acquisition system. Results from gamma-ray irradiations are presented.