Digital holography has been proposed to fulfill a need for an imaging diagnostic capable of in situ monitoring of surface erosion caused by plasma-material interaction in nuclear fusion devices. A digital holography diagnostic for 3D surface erosion measurement has been developed at Oak Ridge National Laboratory with the goal of deployment on a plasma device. A proof-of-concept in situ demonstration is planned which would involve measurement of plasma erosion on targets exposed to an electrothermal arc source. This work presents the results of an ex situ characterization of the capability and limitations of holographic imaging of targets exposed to the arc source. Targets were designed to provide a fiducial for comparison of deformed and unaffected areas. The results indicated that the average net erosion was ∼150 nm/plasma exposure, which is expected to be within the diagnostic's measurement capacity. Surface roughness averages determined by holographic image analysis showed good agreement with measurements taken with a profilometer. The limit of the holography diagnostic's x-y spatial resolution was characterized by comparison with scanning electron microscope imaging.
An electrothermal-arc plasma source (ET-Arc) has been developed to produce transient plasma heat and particle fluxes similar to those produced by edge localized modes onto divertor plasma-facing components in tokamaks. The ET-Arc utilizes a capacitive discharge to send current through a 4-mm-diameter, 9-cm-long capillary source liner. The liner material is ablated to form a high-velocity plasma jet that impacts the target downstream. With the current discharge circuit configuration, pulse lengths are 1 to 2 ms in duration and deliver heat fluxes of 0.25 to 2.1 GW m(-2). The plasma was previously characterized with optical emission spectroscopy (OES) on helium emission lines. The He I line ratios were interpreted with collisional radiative analysis to calculate n(e) and T-e. The electron temperature and electron density ranged from T-e = 1 to 5 eV and n(e) = 10(22) to 10(28) electrons/m(3), respectively. Recently, the vacuum configuration and target of the ET-Arc device were modified to allow greater diagnostic access for plasma-material interaction (PMI) studies and diagnostic development. The diagnostic suite included two Tektronix high-voltage probes to measure the capacitor and discharge potentials, a discharge current monitor, Edgertronic SC1 high-speed cameras to image the discharge, and a FLIR SC4000 infrared camera to estimate heat flux on the target. The system used OES for plasma characterization, but a new Thomson scattering (TS) diagnostic has been implemented. This system is an Advanced Research Projects Agency - Energy (ARPA-E)-funded, portable diagnostic package for spectroscopic measurements of n(e), T-e, n(i), T-i,, and v(i), which includes both TS and OES. Additionally, a novel digital holography (DH) surface-imaging diagnostic was implemented to measure erosion rates in situ. Results from ex situ DH characterization of stainless steel targets exposed to the ET-Arc source indicated that surface erosion of similar to 150 nm per shot occurred and an in situ DH characterization of similar targets was planned. The arc-triggering system will be revised and optimized to better synchronize with the laser diagnostics. Details of the reconfigured ET-Arc source are reported here.
There are currently few viable diagnostic techniques for in situ measurement of plasma facing component erosion. Digital holography is intended to fill this gap. Progress on the development of single and dual CO2 laser digital holography diagnostics for in situ plasma facing component erosion is discussed. The dual laser mode’s synthetic wavelength allows the measurable range to be expanded by a factor of ∼400 compared to single laser digital holography. This allows the diagnostic to measure surface height changes of up to 4.5 μm in single laser mode and up to 2 mm in dual laser mode. Results include ex situ measurements of plasma eroded targets and also dynamic measurements of nm and μm scale motion of a target mounted on a precision translation stage. Dynamic measurements have successfully been made with the system operating in both single and dual laser modes, from ∼50 nm to ∼4 μm in single laser mode and up to ∼400 μm in dual laser mode (limited only by the stage speed and camera acquisition duration). These results demonstrate the feasibility of using digital holography to characterize plasma facing component erosion dynamically, i.e., during plasma exposure. Results of proof-of-principle in situ digital holographic measurements of targets exposed to an electrothermal arc plasma source are presented.
Digital Holographic (DH) imaging is a laser-based measurement technique, which can be used to monitor a material surface as it is being exposed to fusion-relevant plasmas. Both single-laser and dual-laser DH measurements have been demonstrated ex situ at Oak Ridge National Laboratory (ORNL). A DH diagnostic system is being assessed for deployment at ORNL to make in situ, real-time measurements of plasma erosion/redeposition in the Prototype Material Plasma Exposure eXperiment (Proto-MPEX). In situ, real time measurements pose unique challenges to diagnostic systems, which are not encountered by ex situ analysis techniques. The absolute surface height (tracked at the nm to mu m position) during plasma exposure can be modified by: 1) surface movement due to vibration or thrust exerted by the plasma device, 2) surface growth due to the thermal expansion of the material under steady MW/m(2) or transient GW/m(2) plasma heat loads, and 3) surface modification due to plasma erosion/redeposition of the material substrate. To assess these effects, 1) the vibration spectrum of the diagnostic and the pulsed plasma device have been measured, 2) the thermal growth of the surface has been measured for an applied heat flux, and 3) the surface modification has been measured ex situ post plasma exposure, and ex situ post laser ablation as a proxy for the plasma. This paper will provide an overview of the results that have been achieved in the development of a DH diagnostic for in situ real-time measurements of plasma exposed surfaces in the Proto-MPEX device.
A digital holography device is currently undergoing development at the Oak Ridge National Laboratory for the purpose of measuring surface topography, with the goal of deployment as a real-time plasma-facing component diagnostic for the study of materials that could be utilized in a nuclear fusion device. The holography system utilizes one or two lasers depending on the scale of surface features under measurement. Measurements of surface roughness were performed in a single-laser mode and compared with the data from profilometry, with a linear correlation of increased holographic measurement fidelity as surfaces became smoother. Characterization of the dual-laser operating mode has been performed via surface measurement of stainless steel targets with "stair-step" features in various sizes. Results demonstrated that surface features with known sizes as small as 25.4 mu m could be resolved. Measurements were within similar to 55 mu m or less deviation from the actual sizes, and measurement accuracy was improved as feature size was increased, corresponding to the effect of noise becoming less pronounced. A target exposed to plasma generated by an electrothermal (ET) arc source was analyzed with flat-field correction and averaging of sequential image frames to demonstrate the improved measurement quality in preparation for future use of holography on ET arc-exposed targets.
A digital holography (DH) surface erosion/deposition diagnostic is being developed for 3D imaging of plasma facing component surfaces in situ and in real time. Digital holography is a technique that utilizes lasers reflected from a material surface to form an interferogram, which carries information about the topology of the surface when reconstructed. As described in this paper, dual CO2 lasers at 9.271 and 9.250 μm wavelengths illuminate the interrogated surface (at a distance of ∼1 m) in a region of ∼1 cm × 1 cm. The surface feature resolution is ∼0.1 mm in the plane of the surface, and the depth resolution ranges from ∼0.0001 to ∼2 mm perpendicular to the surface. The depth resolution lower limit is set by single-laser and detector optical limitations, while the upper limit is determined by 2π phase ambiguity of the dual-laser synthetic wavelength. Measurements have been made “on the bench” to characterize the single-laser and dual-laser DH configurations utilizing standard resolution targets and material targets that were previously exposed to high flux plasmas in either the Prototype Material Plasma Exposure eXperiment (Proto-MPEX) or the electro-thermal (ET) arc source. Typical DH measurements were made with 0.03 ms integration with an IR camera that can be framed at rates approaching 1.5 kHz. The DH diagnostic system is progressing toward in situ measurements of plasma erosion/deposition either on Proto-MPEX or the ET arc source.
An instrument was developed using digital holographic reconstruction of the wavefront from a CO2 laser imaged on a high-speed commercial IR camera. An acousto-optic modulator is used to generate 1-25 μs pulses from a continuous-wave CO2 laser, both to limit the average power at the detector and also to freeze motion from sub-interframe time scales. Extensive effort was made to characterize and eliminate noise from vibrations and second-surface reflections. Mismatch of the reference and object beam curvature initially contributed substantially to vibrational noise, but was mitigated through careful positioning of identical imaging lenses. Vibrational mode amplitudes were successfully reduced to ≲1 nm for frequencies ≳50 Hz, and the inter-frame noise across the 128 × 128 pixel window which is typically used is ≲2.5 nm. To demonstrate the capabilities of the system, a piezo-electric valve and a reducing-expanding nozzle were used to generate a super-sonic gas jet which was imaged with high spatial resolution (better than 0.8 lp/mm) at high speed. Abel inversions were performed on the phase images to produce 2-D images of localized gas density. This system could also be used for high spatial and temporal resolution measurements of plasma electron density or surface deformations.
A project has been started at ORNL to develop a dual-wavelength digital holography system for plasma facing component erosion measurements on prototype material plasma exposure experiment. Such a system will allow in situ real-time measurements of component erosion. Initially the system will be developed with one laser, and first experimental laboratory measurements will be made with the single laser system. In the second year of development, a second CO2 laser will be added and measurements with the dual wavelength system will begin. Adding the second wavelength allows measurements at a much longer synthetic wavelength.
In situ, real time measurement of net plasma-facing-component (PFC) erosion/deposition in a real plasma device is challenging due to the need for good spatial and temporal resolution, sufficient sensitivity, and immunity to fringe-jump errors. Design of a high-sensitivity, potentially high-speed, dual-wavelength CO2 laser digital holography system (nominally immune to fringe jumps) for PFC erosion measurement is discussed.
The state of the art in electro-optics has advanced to the point where digital holographic acquisition of wavefronts is now possible. Holographic wavefront acquisition provides the phase of the wavefront at every measurement point. This can be done with accuracy on the order of a thousandth of a wavelength, given that there is sufficient care in the design of the system. At wave frequencies which are much greater than the plasma frequency, the plasma index of refraction is linearly proportional to the electron density and wavelength, and the measurement of the phase of a wavefront passing through the plasma gives the chord-integrated density directly for all points measured on the wavefront. High-speed infrared cameras (up to ∼40,000 fps at ∼64×4 pixels) with resolutions up to 640×512 pixels suitable for use with a CO(2) laser are readily available, if expensive.
Plasma fuelling with pellet injection, pacing of edge localized modes (ELMs) by small frequent pellets and disruption mitigation with gas jets or injected solid material are some of the most important technological capabilities needed for successful operation of ITER. Tools are being developed at the Oak Ridge National Laboratory that can be employed on ITER to provide the necessary core pellet fuelling and the mitigation of ELMs and disruptions. Here we present progress on the development of the technology to provide reliable high throughput inner wall pellet fuelling, pellet ELM pacing with high frequency small pellets and disruption mitigation with gas jets and shattered pellets. Examples of how these tools can be employed on ITER are discussed.
We present a computational method to increase the effective NA of a holographic microscopy system operating in air. Our optical system employs a reflection Mach-Zender architecture and computational reconstruction of the full complex (phase and amplitude) wavefront. Based on fundamental diffraction principles, different angles of incident illumination result in different diffracted orders of the object wave being imaged. We record, store, and computationally recombine these object waves to expand the spatial frequency response. Experimental results demonstrate an improvement in the effective NA of our system from 0.59 to 0.78.