This paper presents a first demonstration of range-resolved differential absorption LIDAR (DIAL) measurements of the water vapor main isotopologue H2 16O and the less abundant semi-heavy water isotopologue HD16O with the aim of determining the isotopic ratio. The presented Water Vapor and Isotope Lidar (WaVIL) instrument is based on a parametric laser source emitting nanosecond pulses at 1.98 µm and a direct-detection receiver utilizing a commercial InGaAs PIN photodiode. Vertical profiles of H2 16O and HD16O were acquired in the planetary boundary layer in the suburban Paris region up to a range of 1.5 km. For time averaging over 25 min, the achieved precision in the retrieved water vapor mixing ratio is 0.1 g kg-1 (2.5% relative error) at 0.4 km above ground level (a.g.l.) and 0.6 g kg-1 (20%) at 1 km a.g.l. for 150 m range bins along the LIDAR line of sight. For HD16O, weaker absorption has to be balanced with coarser vertical resolution (600 m range bins) in order to achieve similar relative precision. From the DIAL measurements of H2 16O and HD16O, the isotopic abundance δD was estimated as -51‰ at 0.4 km above the ground and -119‰ in the upper part of the boundary layer at 1.3 km a.g.l. Random and systematic errors are discussed in the form of an error budget, which shows that further instrumental improvements are required on the challenging path towards DIAL-profiling of the isotopic abundance with range resolution and precision suitable for water cycle studies.
Improved understanding of the variability underlying the distribution of stable water isotopologues in the troposphere, using both observations and modelling, has proven to be invaluable to study processes related to the hydrological cycle on a local as well as global scale. To date though, existing observation means (CRDS from ground-based or airborne platforms, passive remote sensing from space) only provide a partial picture of the complexity of the process at play due to their limited spatial or temporal coverage. On the other hand, laser active remote sensing, and in particular differential absorption lidars (DIAL) can deliver reliable, continuous, highly resolved (150 m, 10 min) profiles of H216O and HD16O in the lower troposphere, thereby providing observational insights into small scale processes such as evapotranspiration above continental surfaces and mixing in the planetary boundary layer. Such a lidar system is currently in development (WaVIL project funded by ANR) that will operate at 1.98 µm where water isotopologues exhibit close but distinct absorption features, sensitive photodetectors are commercially available, and where pulsed laser emission over 10 mJ can be achieved using for instance parametric conversion. In order to assess the expected instrument performances and to evaluate the potential of a ground-based system for simultaneous measurement of H216O and HD16O, we performed an error budget based on an end-to-end simulator. Lidar backscatter signals were simulated for different instrument-specific and atmospheric parameters. On the instrument side, calculations were performed for a commercial InGaAs PIN photodiode and for a state of the art low-noise HgCdTe avalanche photodiode. The sensitivity to environmental factors was investigated exemplarily for mid-latitude, arctic, and tropical environments where both vertical water vapor and aerosol variability were accounted for. Vertical profiles of aerosol extinction and backscatter coefficients were derived from the AERONET database (https://aeronet.gsfc.nasa.gov/) and extrapolated to the 2 µm spectral region, taking statistical seasonality into account. Performance simulations have been also conducted using vertical profiles derived from a field campaign where water vapor isotopologue concentrations and aerosol extinction were measured. We will outline the majority biases for such a lidar system and how statistical errors can be mitigated in a view of a forthcoming airborne DIAL instrument.
We present the design of a differential absorption LIDAR targeting HDO/H216O isotopic ratio measurement with high vertical resolution. This approach is enabled by infrared water vapor spectroscopy and recent high power multi-species parametric emitter developments.