This study investigates the electrostatic and electrochemical behavior of polyaniline (PANI) and its composite with amine-functionalized multi-walled carbon nanotubes (PANI/MWCNT-NH2) to elucidate the mechanisms governing ammonia (NH3) sensing. High-resolution atomic force microscopy (AFM) coupled with electrostatic force microscopy (EFM) demonstrates that pristine PANI forms granular macroaggregates with localized charge distribution, whereas MWCNT incorporation promotes worm-like percolative networks that enhance charge delocalization and conductivity. Electrochemical characterization by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) corroborates these nanoscale observations, revealing significantly improved interfacial electron transfer kinetics in the composite. Upon exposure to NH3, pristine PANI undergoes rapid de-doping and nonlinear signal suppression, while the composite exhibits a more progressive electrochemical modulation. Overall, the results demonstrate that NH3 sensing in PANI-based films is governed not solely by electroactive material content but by the interplay between nanoscale morphology, electrostatic heterogeneity, and charge transport topology. The nanotube-mediated formation of delocalized and percolative conductive pathways provides structural and electrochemical robustness, enabling tunable, high-sensitivity operation suitable for next-generation, low-power ammonia sensing platforms.
The NerveRepack project is a European initiative that aims to develop biomimetic exoskeletons/exoprostheses for amputated or paralyzed leg patients that will receive and transmit signals to enable movements and sensations for the patient. To implement the project, it is fundamental to develop implantable neuronal electrodes that will allow bidirectional signaling between the sensors placed on the exoskeletons/exoprostheses and the nervous system. In this direction, two electrodes, plug and cuff, have been designed as integral parts of the final implantable device. The electrodes should comply with strict regulations to ensure their safe implantation in patients. The purpose of this study was to support the compliance of the implant platforms of certain key components with the ISO and ASTM standards that would be required for clinical applications. We have used an indirect method to assess the biocompatibility of the developed electrodes against neuronal cells, fibroblasts, and keratinocytes. Also, we assessed hemocompatibility, i.e., the potential of implantable electrodes to induce hemolysis or complement activation. Finally, the mutagenic/genotoxic potential was tested against the internationally recommended CHO cells. Both representative plug and cuff electrode components were found non-cytotoxic, non-mutagenic, and unable to induce hemolysis. Therefore, from the point of early evaluation of in vitro material and process biocompatibility, the selected implant platforms for the electrodes could be implanted in preclinical models to delineate their potential in vivo applications as neuronal interface with the biomimetic exoskeleton/exoprostheses.
There is great interest in the development of prosthetic limbs capable of complex activities that are wirelessly connected to the patient's neural system. Although some progress has been achieved in this area, one of the main problems encountered is the selective acquisition of nerve impulses and the closing of the automation loop through the selective stimulation of the sensitive branches of the patient. Large-scale research and development have achieved so-called "cuff electrodes"; however, they present a big disadvantage: they are not selective. In this article, we present the progress made in the development of an implantable system of plug neural microelectrodes that relate to the biological nerve tissue and can be used for the selective acquisition of neuronal signals and for the stimulation of specific nerve fascicles. The developed plug electrodes are also advantageous due to their small thickness, as they do not trigger nerve inflammation. In addition, the results of the conducted tests on a sous scrofa subject are presented.
With the global market value of sensors on the rise, this paper focuses on the fabrication and testing of a proof-of-concept piezoelectric energy harvester which is able to harvest mechanical energy from the ambient environment and convert it into electrical energy in order to power wireless sensor networks. We focused on obtaining a new device structure based on a comb-type array of piezoelectric MEMS cantilevers (2 × 10) for a resonant frequency in the environmental application domain (a few hundred Hz) and a chip area of only 1 cm2. The configuration of the lead-free piezoelectric cantilever consists of a Si substrate, a pair of Ti-Pt electrodes and a sputtered piezoelectric layer of 12% Sc-doped AlN with a thickness of 1000 nm, a dielectric constant of ~13 and e31,f = 1.3 C/m2. At a resonant frequency of 465.2 Hz and an acceleration of 1 g, the maximum value for the collected power was 2.53 µW for an optimal load resistance of 1 MΩ resulting in a power density of 60.2 nW/mm3 for the unpacked device, without taking into account the vibration volume. By increasing the excitation acceleration to 2 g RMS and using LTC3588-1 for the power circuitry we were able to obtain a stabilized output voltage of 1.8 V.
Hydrogels are a viable option for biomedical applications due to their biocompatibility, biodegradability, and ability to incorporate various healing agents while maintaining their biological efficacy. This study focused on the preparation and characterization of novel hybrid hydrogels enriched with the natural algae compound Ulvan for potential use in wound dressings. The characterization of the hydrogel membranes involved multiple methods to assess their structural, mechanical, and chemical properties, such as pH measurements, swelling, moisture content and uptake, gel fraction, hydrolytic degradation, protein adsorption and denaturation tests, rheological measurements, SEM, biocompatibility testing, and scratch wound assay. The hydrogel obtained with a higher concentration of Ulvan (1 mg/mL) exhibited superior mechanical properties, a swelling index of 264%, a water content of 55%, and a lower degradation percentage. In terms of rheological properties, the inclusion of ULV in the hydrogel composition enhanced gel strength, and the Alginate + PVA + 1.0ULV sample demonstrated the greatest resistance to deformation. All hydrogels exhibited good biocompatibility, with cell viability above 70% and no obvious morphological modifications. The addition of Ulvan potentiates the regenerative effect of hydrogel membranes. Subsequent studies will focus on encapsulating bioactive compounds, investigating their release behavior, and evaluating their active biological effects.
$NO_{2}$ emissions are one of the main sources of pollution in urban environments. Thus, gas sensors based on gold interdigitated electrodes and polypyrrole sensing layers have been investigated for its monitoring at room temperature. During the investigation it was determined that the addition of Ferrocene to a sensing layer consisting of a polypyrrole, reduced graphene oxide composite material sensing layer leads to a significant increase in both the sensitivity and linearity of the resulting sensor. Moreover, polypyrrole sensors have been identified to have excellent temporal stability, retaining a reproducible measurement even after two years of storage.
Sensor systems for monitoring indoor air quality are vital for the precise quantification of the mechanisms which lead to the deterioration of human health, with a typical person spending an average of 20 h a day in an enclosed space. Thus, a series of layered chemoresistive sensors, obtained by the facile electrodeposition of carbon nanomaterial-enhanced PANI composites, have been tested for the selective detection of two core indoor pollutants: ammonia and nitrogen dioxide. The sensors were tested with respect to sensitivity and selectivity to the target gasses, with performance being assessed based on response linearity and repeatability at room temperature. Of the tested sensors, two have been identified as having an adequate performance on ammonia, with sensitivities of up to 96.99% and resolutions of up to 0.85 ppm being observed, while on nitrogen dioxide, despite the successful sensor having a lower sensitivity, 10.71%, it has shown high resolution, 1.25 ppm, and linearity over a large concentration domain. These high performances highlight the viability of multi-layers chemosensors based on the electrodeposition of nanomaterial-enhanced conductive polymers for the detection of pollutant gasses, with finetuning of the detection layer allowing the accurate monitoring of a wide range of gasses.
Detection of greenhouse gases is essential because harmful gases in the air diffuse rapidly over large areas in a short period of time, causing air pollution that will induce climate change with catastrophic consequences over time. Among the materials with favorable morphologies for gas detection (nanofibers, nanorods, nanosheets), large specific surfaces, high sensitivity and low production costs, we chose nanostructured porous films of In2O3 obtained by the sol-gel method, deposited on alumina transducers, with gold (Au) interdigitated electrodes (IDE) and platinum (Pt) heating circuits. Sensitive films contained 10 deposited layers, involving intermediate and final thermal treatments to stabilize the sensitive film. The fabricated sensor was characterized using AFM, SEM, EDX and XRD. The film morphology is complex, containing fibrillar formations and some quasi-spherical conglomerates. The deposited sensitive films are rough, thus favoring gas adsorption. Ozone sensing tests were performed at different temperatures. The highest response of the ozone sensor was recorded at room temperature, considered to be the working temperature for this specific sensor.
Healthcare professionals face an ongoing challenge in managing both acute and chronic wounds, given the potential impact on patients' quality of life and the limited availability of expensive treatment options. Hydrogel wound dressings offer a promising solution for effective wound care due to their affordability, ease of use, and ability to incorporate bioactive substances that enhance the wound healing process. Our study aimed to develop and evaluate hybrid hydrogel membranes enriched with bioactive components such as collagen and hyaluronic acid. We utilized both natural and synthetic polymers and employed a scalable, non-toxic, and environmentally friendly production process. We conducted extensive testing, including an in vitro assessment of moisture content, moisture uptake, swelling rate, gel fraction, biodegradation, water vapor transmission rate, protein denaturation, and protein adsorption. We evaluated the biocompatibility of the hydrogel membranes through cellular assays and performed instrumental tests using scanning electron microscopy and rheological analysis. Our findings demonstrate that the biohybrid hydrogel membranes exhibit cumulative properties with a favorable swelling ratio, optimal permeation properties, and good biocompatibility, all achieved with minimal concentrations of bioactive agents.
Green chemistry is a pharmaceutical industry tool, which, when implemented correctly, can lead to a minimization in resource consumption and waste. An aqueous extract of Salix alba L. was employed for the efficient and rapid synthesis of silver/gold particle nanostructures via an inexpensive, nontoxic and eco-friendly procedure. The nanoparticles were physicochemically characterized using ultraviolet–visible spectroscopy (UV–Vis), Fourier transform infrared spectroscopy (FT-IR), dynamic light scattering (DLS), X-ray diffraction (XRD) and scanning electron microscopy (SEM), with the best stability of up to one year in the solution obtained for silver nanoparticles without any chemical additives. A comparison of the antimicrobial effect of silver/gold nanoparticles and their formulations (hydrogels, ointments, aqueous solutions) showed that both metallic nanoparticles have antibacterial and antibiofilm effects, with silver-based hydrogels having particularly high antibiofilm efficiency. The highest antibacterial and antibiofilm efficacies were obtained against Pseudomonas aeruginosa when using silver nanoparticle hydrogels, with antibiofilm efficacies of over 75% registered. The hydrogels incorporating green nanoparticles displayed a 200% increased bacterial efficiency when compared to the controls and their components. All silver nanoparticle formulations were ecologically obtained by “green synthesis” and were shown to have an antimicrobial effect or potential as keratinocyte-acting pharmaceutical substances for ameliorating infectious psoriasis wounds.
The natural differences between human-made electronics and biological tissues constitute a huge challenge in materials and the manufacturing of next-generation bioelectronics. As such, we performed a series of consecutive experiments for testing the biofunctionality and biocompatibility for device implantation, by changing the exterior chemical and physical properties of electronics coating it with silicone or hydrogels. In this article, we present a comparison of the main characteristics of an electronic device coated with either silicone or hydrogel (GelMa). The coating was performed with a bioprinter for accurate silicone and hydrogel deposition around different electronic chips (Step-Down Voltage Regulator U3V15F5 from Pololu Corporation). The results demonstrate that the hydrogel coating presents an augmented biomechanical and biochemical interface and superior biocompatibility, lowers foreign body response, and considerably extends the capabilities for bioelectronic applications.
Nanocomposite materials have seen increased adoption in a wide range of applications, with toxic gas detection, such as carbon monoxide (CO), being of particular interest for this review. Such sensors are usually characterized by the presence of CO absorption sites in their structures, with the Langmuir reaction model offering a good description of the reaction mechanism involved in capturing the gas. Among the reviewed sensors, those that combined polymers with carbonaceous materials showed improvements in their analytical parameters such as increased sensitivities, wider dynamic ranges, and faster response times. Moreover, it was observed that the CO reaction mechanism can differ when measured in mixtures with other gases as opposed to when it is detected in isolation, which leads to lower sensitivities to the target gas. To better understand such changes, we offer a complete description of carbon nanostructure-based chemosensors for the detection of CO from the sensing mechanism of each material to the water solution strategies for the composite nanomaterials and the choice of morphology for enhancing a layers’ conductivity. Then, a series of state-of-the-art resistive chemosensors that make use of nanocomposite materials is analyzed, with performance being assessed based on their detection range and sensitivity.
In this article, we present our research achievements regarding the development of a remote sensing system for motor pulse acquisition, as a first step towards a complete neuroprosthetic arm. We present the fabrication process of an implantable electrode for nerve impulse acquisition, together with an innovative wirelessly controlled system. In our study, these were combined into an implantable device for attachment to peripheral nerves. Mechanical and biocompatibility tests were performed, as well as in vivo testing on pigs using the developed system. This testing and the experimental results are presented in a comprehensive manner, demonstrating that the system is capable of accomplishing the requirements of its designed application. Most significantly, neural electrical signals were acquired and transmitted out of the body during animal experiments, which were conducted according to ethical regulations in the field.
Undoped and Zn-doped ITO (ITO:Zn) multifunctional thin films were successfully synthesized using the sol–gel and dipping method on three different types of substrates (glass, SiO2/glass, and Si). The effect of Zn doping on the optoelectronic, microstructural, and gas-sensing properties of the films was investigated using X-ray diffraction (XRD), atomic force microscopy (AFM), scanning electron microscopy (SEM), transmission electron microscopy (TEM), spectroscopic ellipsometry (SE), Raman spectroscopy, Hall effect measurements (HE), and gas testing. The results showed that the optical constants, the transmission, and the carrier numbers were correlated with the substrate type and with the microstructure and the thickness of the films. The Raman study showed the formation of ITO films and the incorporation of Zn in the doped film (ITO:Zn), which was confirmed by EDX analysis. The potential use of the multifunctional sol–gel ITO and ITO:Zn thin films was proven for TCO applications or gas-sensing experiments toward CO2. The Nyquist plots and equivalent circuit for fitting the experimental data were provided. The best electrical response of the sensor in CO2 atmosphere was found at 150 °C, with activation energy of around 0.31 eV.
Herein is presented the biosynthesis methods employed in synthesising silver nanoparticles from Artemisia annua L.. Important physico-chemical parameters were determined for the silver nanoparticles obtained after biosynthesis using UV-VIS spectrometry, FTIR, SEM, zeta potential and DLS. The silver nanoparticles were used for soap formulations and the resulting physical chemical parameters were compared to those of a commercial soap. The soaps met the quality standards, with quality parameters being comparable with those of commercial soaps. On further verification of the antibacterial benefits demonstrated in soaps with silver nanoparticles, this could prove a beneficial product for wide consumption.
Recently the emissions of volatile organic compounds (VOCs) in the atmosphere have increased dramatically with rapid development of urbanization and industry. This led to a large decline in air quality around the world, which resulted in a heavy impact on human health. Therefore, new/cheap detection devices for VOCs are of high interest. Formaldehyde (FA) is a very toxic VOC, which damages the respiratory system even in the smallest doses and short exposure time. Zinc oxide (ZnO)/nickel oxide (NiO) heterostructures were synthesized using an economical route: firstly, NiO was prepared by liquid exfoliation technique and deposited by dip-coating on alumina ceramic transducers with two interdigital gold (Au) electrodes, followed by low—temperature hydrothermal growth of ZnO. The as-prepared sensors were characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM-EDAX), and X-Ray fluorescence (XRF). The response/recovery of ZnO/NiO heterostructure-based microsensors for formaldehyde was investigated at room temperature, in agreement with modern sensing requirements. The sensor operating voltage was varied between 1.5 and 5.0 V direct current (DC), to achieve the best sensor performance.
The low-power sensing platform proposed by the Convergence project is foreseen as a wireless, low-power and multifunctional wearable system empowered by energy-efficient technologies. This will allow meeting the strict demands of life-style and healthcare applications in terms of autonomy for quasi-continuous collection of data for early-detection strategies. The system is compatible with different kinds of sensors, able to monitor not only health indicators of individual person (physical activity, core body temperature and biomarkers) but also the environment with chemical composition of the ambient air (NOx, COx, NHx particles) returning meaningful information on his/her exposure to dangerous (safety) or pollutant agents. In this article, we introduce the specifications and the design of the low-power sensing platform and the different sensors developed in the project, with a particular focus on pollutant sensing capabilities and specifically on NO2 sensor based on graphene and CO sensor based on polyaniline ink.
In recent years, research into the field of materials for flexible sensors and fabrication techniques directed towards wearable devices has helped to raise awareness of the need for new sensors with healthcare applicability. Our goal was to create a wearable flexible pressure sensor that could be integrated into a clinically approved blood pressure monitoring device. The sensor is built from a microfluidic channel encapsulated between two polymer layers, one layer being covered by metal transducers and the other being a flexible membrane containing the microfluidic channel, which also acts as a sealant for the structure. The applied external pressure deforms the channel, causing changes in resistance to the microfluidic layer. Electrical characterization has been performed in 5 different configurations, using alternating current (AC) and (DC) direct current measurements. The AC measurements for the fabricated pressure sensor resulted in impedance values at tens of hundreds of kOhm. Our sensor proved to have a high sensitivity for pressure values between 0 and 150 mm Hg, being subjected to repeatable external forces. The novelty presented in our work consists in the unique technological flow for the fabrication of the flexible wearable pressure sensor. The proposed miniaturized pressure sensor will ensure flexibility, low production cost and ease of use. It is made of very sensitive microfluidic elements and biocompatible materials and can be integrated into a wearable cuffless device for continuous blood pressure monitoring.
Carboxylic acid functionalized single-walled carbon nanotubes and poly (3,4-ethylenedioxythiophene), C-SWCNT:PEDOT, were homogenously electrodeposited onto working electrodes (WE) in order to develop an acetylcholinesterase (AChE)-based biosensor. RAMAN, FTIR, SEM, EDX and electrochemical methods provided evidence for the enzyme immobilization and the conducting composite formation. The SWCNT dissolved in poly (sodium 4-styrenesulphonate) (PSS), and 3,4-ethylenedioxythiophene (EDOT) dissolved in polyethyleneglicol (PEG) were used for composite electrodeposition to provide a homogenous layer and a compatible environment around the AChE. The composite C-SWCNT:PEDOT has proved to be highly efficient for retaining the activity and stability of AChE and also for promoting the electron transfer reaction to the gold electrode. Under optimized experimental conditions, the inhibition of dichlorvos (DVSO) on AChE showed a proportional inhibition current signal with increasing concentrations of DVSO in the range 1 ppb to 600 ppb. The correlation coefficient obtained with spectrophotometer enzyme assay method versus a biosensor was 0.989. It showed high accuracy, precision. The detection limits were 5.54 ppb using the CA method and 0.447 ppb using differential pulse voltammetry (DPV). Both values are below the permitted limit for DVSO in fruit and vegetables. The sensor showed stability and could be used as a disposable amperometric sensor with potential application for monitoring organophosphorus pesticides.