We examine and then optimize alignment of chromatograms collected on nominally identical columns using retention time locking (RTL), an instrumental alignment tool, and software-based alignment using correlation optimized warping (COW). For this purpose, three samples are constructed by spiking two sets of analytes into a base test mixture. The three samples are analyzed by high-speed gas chromatography with four nominally identical columns and identical separation conditions. The data is first analyzed without alignment, then using COW alone, then RTL alone, and finally with RTL followed by COW to correct the severe column-to-column misalignment. Principal component analysis (PCA) is used to investigate how well each alignment method clustered the chromatograms into the three sample classes via a scores plot without being compromised by the specific column(s) used. The degree-of-class separation (DCS) is used as a classification metric, measured as the Euclidian distance between the centroids of two clusters in PC space in the scores plot, normalized by their pooled variance. With no alignment, the average DCS between sample classes (DCSsam) was 3.0, while the average DCS between the four nominally identical columns, i.e., column classes (DCScol) was 76.1 (ideally the DCScol should be 0), indicating the chromatograms were initially classified by the columns used. Using either COW or RTL alone also produced unsatisfactory results, with COW alone incorrectly aligning many peaks, leading to a DCSsam of only 1.9 and DCScol of 1.7, while RTL alone provided a DCSsam of 4.7 and DCScol of 4.2. Finally, using RTL followed by COW alignment, DCSsam increased to 32.5, indicating successful classification by chemical differences between sample classes, while the DCScol decreased to 0.4, indicating virtually no classification due to column-to-column differences, as desired. Thus, RTL provided a "first-order" correction of the initial retention mismatch observed for the nominally identical columns, while additional alignment via COW was required to optimize sample classification by PCA.
We investigate the extent to which comprehensive three-dimensional gas chromatography (GC3) provides a signal enhancement (SE) and a signal-to-noise ratio enhancement (S/NRel) relative to one-dimensional (1D)-GC. Specifically, the SE is defined as the ratio of the tallest 3D peak height from the GC3 separation to the 1D peak height from the unmodulated 1D-GC separation. A model is proposed which allows the analyst to predict the theoretically attainable SE (SET) based upon the peak width and sampling density inputs. The model is validated via comparison of the SET to the experimentally measured SE (SEM) obtained using total-transfer GC3 (100% duty cycle for both modulators) with time-of-flight mass spectrometry detection. Two experimental conditions were studied using the same GC3 column set, differing principally in the modulation period from the 1D to 2D columns: 4 s versus 8 s. Under the first set of conditions, the average SEM was 97 (±22), in excellent agreement with the SET of 97 (±18). The second set of conditions improved the average SEM to 181 (±27), also in agreement with the average SET of 176 (±26). The average S/NRel following correction for the mass spectrum acquisition frequency was 38.8 (±11.2) and 59.0 (±27.2) for the two sets of conditions. The enhancement in S/N is largely attributed to moving the signal to a higher frequency domain where the impact of "low frequency" noise is less detrimental. The findings here provide strong evidence that GC3 separations can provide enhanced detectability relative to 1D-GC and comprehensive two-dimensional gas chromatography (GC×GC) separations.
Dynamic pressure gradient modulation (DPGM) in full modulation mode is optimized for comprehensive two-dimensional (2D) gas chromatography (GC × GC) with time-of-fight mass spectrometry (TOFMS) detection to obtain high peak capacity separations and demonstrate broad applicability for complex samples. A pulse valve introduces an auxiliary carrier gas flow at a T-union connecting the first dimension (1D) column to the second dimension (2D) column. At a sufficiently high auxiliary pressure (Paux) the 1D flow is temporarily stopped. Then, during each modulation period (PM) the valve is turned off briefly, a period termed the pulse width (pw), allowing the 1D effluent to essentially be reinjected onto the 2D column for the modulated separations. Modifications to the modulator assembly are provided to improve performance. Method optimization is demonstrated for a 116-component test mixture by tuning the Paux and the pw. For a PM = 2 s and 1F of 0.10 ml/min, the optimal pw and initial Paux selected were 200 ms and 330.9 kPa (33 psig), respectively. The 30 min separation of the test mixture provided a 1D peak capacity of 1nc = 330 and a 2D peak capacity of 2nc = 15, hence an ideal 2D peak capacity nc,2D = 1nc × 2nc = 4950. Likewise, the 2D peak capacity corrected for undersampling of the 1D separation was 4500 and corrected for both undersampling and sampling variation via statistical overlap theory was 4090. These results provide a 2-fold improvement in peak capacity relative to the previous DPGM study in full modulation mode for GC × GC-TOFMS. The optimized conditions were applied for a variety of applications: diesel fuel, derivatized cow serum, solid phase microextraction (SPME) of coffee headspace, and SPME of river water headspace. Additionally, the fraction of 2D separation space utilized (fcoverage), as defined by the minimum convex hull method, ranged from 0.60 to 0.85. We observed that any fcoverage correction to 2D peak capacity is highly sample dependent, since all samples, except for the diesel sample, were run with the same separation conditions, and yet the fcoverage ranged from 0.60 to 0.80.
Basic principles are introduced for implementing discovery-based analysis with automated quantification of data obtained using comprehensive three-dimensional gas chromatography with flame ionization detection (GC(3)-FID). The GC(3)-FID instrument employs dynamic pressure gradient modulation, providing full modulation (100% duty cycle) with a fast modulation period (PM) of 100 ms. Specifically, tile-based Fisher-ratio analysis, previously developed for comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry (GCxGC-TOFMS), is adapted and applied for GC(3)-FID where the third chromatographic dimension (D-3) is treated as the "spectral" dimension. To evaluate the instrumental platform and software implementation, ten "non-native" compounds were spiked into a ninety-component base mixture to create two classes with a concentration ratio of two for the spiked analyte compounds. The Fisher ratio software identified 95 locations of potential interest (i.e., hits), with all ten spiked analytes discovered within the top fourteen hits. All 95 hits were quantified by a novel signal ratio (S-ratio) algorithm portion of the F-ratio software, which determines the time-dependent S-ratio of the D-3 chromatograms from one class to another, thus providing relative quantification. The average S-ratio for spiked analytes was 1.94 +/- 0.14 mean absolute error (close to the nominal concentration ratio of two), and 1.06 +/- 0.16 mean absolute error for unspiked (i.e., matrix) components. The appearance of the S-ratio as a function of D-3 retention time in the GC(3) dataset, referred to as an S-ratiogram, provides indication of peak purity for each hit. The unique shape of the S-ratiogram for hit 1, alpha-pinene, suggested likely D-3 overlap. Parallel factor analysis (PARAFAC) decomposition of the hit location confirmed that overlap was occurring and successfully decomposed alpha-pinene from a highly overlapped (R-3(s) = 0.1) matrix interferent. (C) 2020 Elsevier B.V. All rights reserved.
Comprehensive three-dimensional (3D) gas chromatography (GC3) coupled to time-of-flight-mass spectrometry (GC3-TOFMS) is an intriguing extension of the well-established comprehensive two-dimensional gas chromatography (GC×GC) technique. Although impressive gains have been made in the instrumentation realm, the utility of non-targeted chemometric analysis of GC3-TOFMS data has yet to be explored. Herein, we present the first application of principal component analysis (PCA) to a GC3-TOFMS dataset of jet fuel samples. Five replicates each of four jet fuels (JP8, J1800A, JP4, and JP7) were collected by GC3-TOFMS with commercial thermal modulation from the first-dimension column (1D) to the second-dimension column (2D), and dynamic pressure gradient modulation (DPGM) from the 2D column to the third-dimension column (3D), thus providing full mass transfer (100% duty cycle both modulation stages). A novel re-registration technique is introduced in which a user-selected series of vacant 3D modulations are removed to correct 2D shifting and effectively “center” the data. This shifting has consistently been observed in the 2D versus 1D view of GC3-TOFMS chromatograms, likely due to the slowed flow on 2D in DPGM and/or temperature programming effects. The 3D PCA loadings of the re-registered data revealed subtle chemical differences between the fuels which would not be as easily elucidated using PCA of GC×GC data. Finally, PCA of the two most chemically similar fuels (J1800A and JP7) revealed additional chemical differences which were drowned out in the initial multi-fuel PCA model, highlighting the potential advantage of “pairwise” PCA for multi-class GC3-TOFMS datasets.
We report the discovery, preliminary investigation, and demonstration of a novel form of differential flow modulation for comprehensive two-dimensional (2D) gas chromatography (GC×GC). Commercially available components are used to apply a flow of carrier gas with a suitable applied auxiliary gas pressure (Paux) to a T-junction joining the first (1D) and second (2D) dimension columns. The 1D eluate is confined at the T-junction, and introduced for 2D separation with a cyclic rhythm, dependent upon the relationship of the modulation period (PM) to the pulse width (pw), where pw is defined as the time interval when the auxiliary gas flow at the T-junction is off. We refer to this flow modulation technique as "dynamic pressure gradient modulation" (DPGM) since a pressure gradient oscillates with the PM along the 1D and 2D column ensemble providing temporary stop-flow conditions and fast 2D flow rates, resulting in 100% duty cycle and full modulation. A 90-component test mixture was used to evaluate the technique with a pw of 60 ms and a PM of 750 ms. The resulting peaks were narrow, with 2Wb ranging from about 20-180 ms. With an average 1Wb of 3 s and a 2nc of 10, a 2D peak capacity, nc,2D, for the 25 min separation was 5000. The detector response enhancement factor (DREF) is reported, defined as the peak height of the highest modulated 2D peak divided by the unmodulated 1D peak height (DREF = 2h/1h). The DREF ranged from about 7-87, depending on the 1Wb and 2Wb for a given analyte. A diesel sample was analyzed to demonstrate performance with a complex sample. Based upon the average 1Wb of 5 s and an average 2Wb of 168 ms, a nc,2D of 8640 was obtained for the 60 min diesel separation. Finally, the modulation principle was investigated as a function of PM, pw, and the volumetric flow rates, 1F and 2F. The measured 2Wb correlate well with the theoretical 2D injected width, given by 2Winj = (1F/2F) ·PM. However, the relevant 1F appears to be dictated by the 1D flow rate when no pressure is applied (during the pw interval), instead of 1F being the average flow rate on 1D (defined by the 1D dead time). The findings provide strong evidence for a differential flow modulation mechanism.