Spaceborne instruments have an irreplaceable role in detecting fundamental vegetation features that link physical properties to ecological theory, but their success depends on our understanding of the complex dynamics that control plant spectral properties—a scale-dependent challenge. We explored differences between the warmer and cooler areas of tree canopies with a ground-based experimental layout consisting of a spectrometer and a thermal camera mounted on a portable crane that enabled synergies between thermal and spectral reflectance measurements at the fine scale. Thermal images were used to characterise the thermal status of different parts of a dense circular cluster of containerised trees, and their spectral reflectance was measured. The sensitivity of the method was found to be unaffected by complex interactions. A statistically significant difference in both reflectance in the visible (VIS), near-infrared (NIR), and shortwave infrared (SWIR) bands and absorption features related to the chlorophyll, carotenoid, and water absorption bands was found between the warmer and cooler parts of the canopy. These differences were reflected in the Photochemical Reflectance Index with values decreasing as surface temperature increases and were related to higher carotenoid content and lower Leaf Area Index (LAI) values of the warmer canopy areas. With the increasingly improving resolution of data from airborne and spaceborne visible, near-infrared, and shortwave infrared (VSWIR) imaging spectrometers and thermal infrared (TIR) instruments, the results of this study indicate the potential of synergies between thermal and spectral measurements for the purpose of more accurately assessing the complex biochemical and biophysical characteristics of vegetation canopies.
The combination of urbanization and global warming leads to urban overheating and compounds the frequency and intensity of extreme heat events due to climate change. Yet, the risk of urban overheating can be mitigated by urban green-blue-grey infrastructure (GBGI), such as parks, wetlands, and engineered greening, which have the potential to effectively reduce summer air temperatures. Despite many reviews, the evidence bases on quantified GBGI cooling benefits remains partial and the practical recommendations for implementation are unclear. This systematic literature review synthesizes the evidence base for heat mitigation and related co-benefits, identifies knowledge gaps, and proposes recommendations for their implementation to maximize their benefits. After screening 27,486 papers, 202 were reviewed, based on 51 GBGI types categorized under 10 main divisions. Certain GBGI (green walls, parks, street trees) have been well researched for their urban cooling capabilities. However, several other GBGI have received negligible (zoological garden, golf course, estuary) or minimal (private garden, allotment) attention. The most efficient air cooling was observed in botanical gardens (5.0 ± 3.5°C), wetlands (4.9 ± 3.2°C), green walls (4.1 ± 4.2°C), street trees (3.8 ± 3.1°C), and vegetated balconies (3.8 ± 2.7°C). Under changing climate conditions (2070–2100) with consideration of RCP8.5, there is a shift in climate subtypes, either within the same climate zone (e.g., Dfa to Dfb and Cfb to Cfa) or across other climate zones (e.g., Dfb [continental warm-summer humid] to BSk [dry, cold semi-arid] and Cwa [temperate] to Am [tropical]). These shifts may result in lower efficiency for the current GBGI in the future. Given the importance of multiple services, it is crucial to balance their functionality, cooling performance, and other related co-benefits when planning for the future GBGI. This global GBGI heat mitigation inventory can assist policymakers and urban planners in prioritizing effective interventions to reduce the risk of urban overheating, filling research gaps, and promoting community resilience.
Commonly single-sided natural ventilation is used in temperate climates to provide comfortable and healthy indoor environments. However, within built-up areas it is difficult to predict natural ventilation rates for buildings as they depend on many flow factors and opening type. Here, existing models are evaluated using the nine-month Refresh Cube Campaign (RCC). Pressure-based ventilation rates were determined for a small opening (1% porosity) in a cubical test building (side = 6 m). The building was isolated and then sheltered in a limited staggered building array to simulate turbulent flows in dense urban areas. Internal and external flow, temperature and pressure measurements captured a wide range of scales of variability. Although the Warren and Parkins (1985, WP85) model performed best for 30-min mean ventilation rates, all four models tested underestimated ventilation rates by a factor of 10. As wind dominated the stack effect, new coefficients were derived for the WP85 wind-driven model as a function of wind angle. Predictions were mostly improved, except for directions with complex flow patterns during the sheltered case. For the first time, the relation between ventilation rate and turbulence intensity (TI) around a full-scale building was tested. Results indicate that the wind-driven model for single-sided ventilation in highly turbulent flows (0.5 < TI < 4) can be improved by including TI as a multiplicative factor. Although small window openings with highly turbulent flows are common for sheltered buildings in urban areas, future model development should include a variety of configurations to assess the generality of these results.
The information provided below is an overview of some of the key components. More information is included within the files stored into the database. Other data sets are also linked to. Full-scale: Measurements undertaken at Silsoe, UK, on a pressure tapped cube. Wind, temperature, surface pressure, and concentration measurements were undertaken. Most equipment measured at 10Hz aside from concentration measurements and meteorological measurements. The cube was isolated and surrounded by eight other cubes of similar size during the experiment to monitor the effects of sheltering. Wind-tunnel: Experiments were conducted in the Environmental Flow Research Centre (EnFlo), University of Surrey ‘A’ wind tunnel (low speed open circuit). The test section is 0.6 m high, 0.9 m wide and 4.5 m long and is constructed of wood and metal with glass side panels. Computer fluid Dynamics (CFD) simulation: A transient Navier-Stokes finite-volume simulation k-ω sheer stress transport (SST) scale adaptive simulation (SAS) turbulence model was used to model the isolated cube and array at full-scale in Ansys Fluent 17.1 (Ansys Canonsburg, PA, USA). The k-ω SST SAS model is a hybrid RANS-LES model that has shown superior results to steady state RANS and has been detailed for this purpose in King et al. (2017). For more details see: Gough et al (2019), Gough et al (2018a), Gough et al (2018b) and Gough 2017 (reference list included in files).
Urban trees play an important role in cooling urban microclimates and regulating outdoor thermal comfort. To better understand their contribution to these processes, it is crucial to elucidate urban trees' radiative thermal performance, especially in the infrared (IR) region (approximately 50% of solar radiation). Yet, owing to significant conceptual and methodological challenges, studies on the radiative performance of trees have mainly focused on individual leaves rather than crown-level characteristics. Here we applied a novel conceptual and methodological framework to characterise the crown-level IR radiative performance of 10 lime trees (Tilia cordata), a common urban tree in the UK and Europe. Our results show that reflected and transmitted solar energy from leaves is dominated (>70%) by IR radiation. At the leaf level, transmission and reflection spectra are similar between trees (differences typically < 10% in IR region), including those under significantly different urban stress conditions. However, at the crown-level, substantial variations in IR transflectance spectra (maximum difference > 40% in IR region) were found between trees. These variations were largely due to crown structural differences (leaf number, density, angles), rather than leaf solar interaction character (leaf-level transmittance or reflectance, leaf colour). Crown transflectance measured from the four cardinal directions was significantly different in the IR region (maximum differences circa 30%), and changed substantially with solar time. Hence, a tree's surroundings received very different, and time dependent, levels of solar IR radiation. These findings have significant implications for species selection and control of environmental stress factors in urban microclimates.
With a number of operational centres looking forward to the possibilities of “city scale” NWP and climate modelling it is important to understand the behaviour of order 100 m models over cities. A key issue is how to handle the representation of partially resolved turbulence in these models. In this article we compare the representation of a clear convective boundary‐layer case in London in 100 and 50 m grid‐length versions of the Unified Model (MetUM) with observations. Comparison of Doppler lidar observations of the vertical velocity shows that convective overturning in the boundary layer is broadly well represented in terms of its depth and magnitude. The role of model resolution was investigated by comparing a 50 m grid‐length model with the 100 m one. It is found that, although going to 50 m grid length does not greatly change many of the bulk properties (mixing height, heat flux profiles, etc.) the spatial structure of the overturning is significantly different. This is confirmed with spectral analysis which shows that the 50 m model resolves significantly more of the energetic eddies, and a length‐scale analysis that shows the 50 and 100 m models produce convective structures 2–3 times larger than observed. We conclude that, for the MetUM, model grid‐lengths of order 100 m may well be sufficient for predicting many bulk and statistical properties of convective boundary layers; however, the details of the spatial structures around convective overturning in these situations are likely to be still under‐resolved. Spin‐up artefacts emanating from the inflow boundary of the model are investigated by comparing with a smaller 100 m grid‐length domain which is more dominated by such effects. These manifest themselves as along‐wind boundary‐layer rolls which produce a less realistic comparison with the lidar observations. A stability analysis is presented in order to better understand the formation of these rolls.
Currently, no clear standards exist for determining urban building natural ventilation rates, especially under varying realistic meteorological conditions. In this study, ventilation rates are determined using tracer gas decay and pressure-based measurements for a full-scale (6 m tall) cube. The cube was either isolated (2 months of observations) or sheltered within a staggered array (7 months), for both single-sided and cross ventilation (openings 0.4 m x 1 m). Wind speeds at cube height ranged between 0.04 m s(-1) and 13.1 m s(-1). Errors for both ventilation methods are carefully assessed. There is no discernible linear relation between normalised ventilation rates from the two methods, except for cross ventilation in the array case. The ratio of tracer gas and pressure derived ventilation rates is assessed with wind direction. For single-sided (leeward opening) cases it approached 1. For cross ventilation the ratio was closer to 1 but with more scatter. One explanation is that agreement is better when internal mixing is less jet-dominated, i.e. for oblique directions in the isolated case and for all directions for unsteady array flows. Sheltering may reduce the flushing rate of the tracer gas from the cube relative to internal mixing rate. This new dataset provides an extensive range of conditions for numerical model evaluation and for understanding uncertainty of ventilation rates. Knowledge of the latter is critical in building design.
The large body of natural ventilation research, rarely addresses the effects of the urban area on ventilation rates. A novel contribution to this gap is made by the REFRESH cube campaign (RCC). During 9 months of observations, the Silsoe cube was both isolated and surrounded by a limited asymmetrical staggered array. A wide range of variables were measured continuously, including: local, reference and internal flow, stability, background meteorological conditions, internal temperature, and ventilation rates (pressure difference techniques for cross ventilated cases). This paper tests the impact of the array on the relation between local and reference wind speeds as modified by wind direction and on cross ventilation rates. The presence of the array causes a 50%–90% reduction in normalised ventilation rate when the reference wind direction is normal to the cube. The decrease in natural ventilation varies with wind direction with large amounts of scatter for both setups. The relation between local and reference wind speeds for the array case had two characteristic responses, not explained by reference wind (speed or direction) nor sensitive to averaging period, turbulence intensity or temperature differences. Given the singular response of the CIBSE approach, it is unable to capture these conditions.
Linking synoptic circulation patterns to specific environmental problems is of significance in the Eastern Mediterranean region, which is characterized by increased seasonal climatic variability and a wealth of distinct weather patterns. This study aims to discuss the links between synoptic scale circulation, intra-day variability and sub-hourly temperature changes over Athens. Diurnal cycles of surface atmospheric variability were examined by applying Principal Component Analysis and Integral Quantities Analysis to a four months data set with surface meteorological elements. Sub-hourly temperature changes were identified by applying a simple linear technique. Principal Components, Integral Quantities and temperature change rates (geometric structures) were related with synoptic circulation categories. It was found that the presence of a Closed Low over the area results in intense along-mountain flows, whilst, after the passage of a trough, when a strong northwesterly flow is established over the area, surface recirculation flows develop. On 64% of the days, geometric structures were observed in the hourly temperature time-series, and they were found to occur across all synoptic situations. Clifframps was the most common geometric structure, and step changes were found to be related with recirculation flows.
In urban areas with high air pollution emissions, the boundary layer volume within which gases and particles are diluted is critical to air quality impacts. With advances in ground-based remote sensing technologies and data processing algorithms, observations of layers forming the atmospheric boundary layer (ABL) are becoming increasingly available at high temporal resolution. Here, mixing height (MH) estimates determined from turbulence measurements of Doppler lidars and aerosol-derived mixed layer height (MLH) based on automatic lidar and ceilometer (ALC) observations within the centre of London are assessed. While MH uncertainty increases with shorter duration of vertical stare sampling within the Doppler lidar scan pattern, instrument-related noise of the ALC may result in large MLH errors due to the challenging task of layer attribution. However, when long time series are assessed most of the algorithm- and instrument-related uncertainties average out and therefore become less critical to overall climatological analyses. Systematic differences occur in nocturnal MH from two nearby (3-4 km) sites but MLH estimates at both sites generally agree with MH obtained at the denser urban setting. During daytime, most spatial variations in ABL structure induced by synoptic conditions or land cover heterogeneity at this scale do not exceed measurement uncertainty. Agreement between MH and MLH is clearly affected by ABL aerosol content and cloud conditions. Discrepancies increase with cloud complexity. On average, MH rises ahead of MLH during the morning growth period and peaks earlier in the day. There is a faster afternoon decay of MLH so that MLH and MH converge again around sunset and often have similar nocturnal values. Results demonstrate that turbulence-derived MH and aerosol-derived MLH should not be used interchangeably for purposes of model evaluation, interpretation of surface air quality observations or initialisation of chemical transport models.
A Met Office/Natural Environment Research Council Joint Weather and Climate Research Programme workshop brought together 50 key international scientists from the UK and international community to formulate the key requirements for an Urban Meteorological Research strategy. The workshop was jointly organised by University of Reading and the Met Office.
Simulation of urban airflow and ventilation potential is desirable for building design, however the complex and transient nature of flows in urban environments makes this a challenging task. This study aims to evaluate the capability of a lattice-Boltzmann method (LBM) code deployed on a graphical processing unit (GPU) using a large eddy sub-grid turbulence model for cross-flow ventilation of an idealised cubical building at wind-tunnel scale. ANSYS Fluent is used as a numerical comparison. Façade pressure and ventilation of the cube are investigated for parallel and perpendicular wind directions with the building in isolation and regular array format. Pressures, velocities and ventilation rates are compared to experimental data from wind tunnel and full-scale experiments of the Silsoe cube. Simulations compare favourably with experimental values and between each other. When the cube was surrounded by other cubes, simulations suggest that vortex shedding from up-wind buildings provides pulsating ventilation, improving airflow ingress in the parallel wind cases. A parametric study showed that doubling surrounding building height had a small negative effect on ventilation but was mitigated by high levels of downdraft and flow fluctuations in the vertical plane. Comparatively, doubling the central building height had a net positive effect but caused high internal airspeeds for both angles. The LBM code running on one GPU was several orders of magnitude faster than Fluent with similar accuracy. Simulation time using the LBM approach was several orders of magnitude lower than Fluent.
The study of the boundary layer can be most difficult when it is in transition and forced by a complex surface, such as an urban area. Here, a novel combination of ground-based remote sensing and in situ instrumentation in central London, UK, is deployed, aiming to capture the full evolution of the urban boundary layer (UBL) from night-time until the fully-developed convective phase. In contrast with the night-time stable boundary layer observed over rural areas, the night-time UBL is weakly convective. Therefore, a new approach for the detection of the morning-transition and rapid-growth phases is introduced, based on the sharp, quasi-linear increase of the mixing height. The urban morning-transition phase varied in duration between 0.5 and 4 h and the growth rate of the mixing layer during the rapid-growth phase had a strong positive relationship with the convective velocity scale, and a weaker, negative relationship with wind speed. Wind shear was found to be higher during the night-time and morning-transition phases than the rapid-growth phase and the shear production of turbulent kinetic energy near the mixing-layer top was around six times larger than surface shear production in summer, and around 1.5 times larger in winter. In summer under low winds, low-level jets dominated the UBL, and shear production was greater than buoyant production during the night-time and the morning-transition phase near the mixing-layer top. Within the rapid-growth phase, buoyant production dominated at the surface, but shear production dominated in the upper half of the UBL. These results imply that regional flows such as low-level jets play an important role alongside surface forcing in determining UBL structure and growth.
Building location and orientation with respect to incident wind angle are important parameters in determining wind-driven natural ventilation. Experimentally measured façade pressures and ventilation rates in the Silsoe cube under single-sided and cross-flow ventilation configurations are compared with CFD simulations conducted in OpenFoam and ANSYS Fluent using a typical linear workflow approach. Eight wind directions are studied with the cube in isolation and in a new staggered nine cube array format. Comparison is made using CIBSE's prescribed ventilation calculation method based on internal/external building pressure differences. Ventilation rate in the isolated cube with single-sided opening was comparatively lower than either of the cross-flow cases, and relationships between air change rate and wind angle were much weaker in the array cases. For the single opening case with the isolated cube, ventilation effectiveness decreases as the wind turns towards the opening due to increased short-circuiting of airflows. Turbulent structures close to windows improve mixing in the array case. Simulations suggest that vortex shedding from up-wind buildings provides pulsating ventilation in both window configurations, which may attenuate the negative effects of upwind flow obstruction.
Nine methods to determine local-scale aerodynamic roughness length \((z_{0})\) and zero-plane displacement \((z_{d})\) are compared at three sites (within 60 m of each other) in London, UK. Methods include three anemometric (single-level high frequency observations), six morphometric (surface geometry) and one reference-based approach (look-up tables). A footprint model is used with the morphometric methods in an iterative procedure. The results are insensitive to the initial \(z_{d}\) and \(z_{0}\) estimates. Across the three sites, \(z_{d}\) varies between 5 and 45 m depending upon the method used. Morphometric methods that incorporate roughness-element height variability agree better with anemometric methods, indicating \(z_{d}\) is consistently greater than the local mean building height. Depending upon method and wind direction, \(z_{0}\) varies between 0.1 and 5 m with morphometric \(z_{0}\) consistently being 2–3 m larger than the anemometric \(z_{0}\). No morphometric method consistently resembles the anemometric methods. Wind-speed profiles observed with Doppler lidar provide additional data with which to assess the methods. Locally determined roughness parameters are used to extrapolate wind-speed profiles to a height roughly 200 m above the canopy. Wind-speed profiles extrapolated based on morphometric methods that account for roughness-element height variability are most similar to observations. The extent of the modelled source area for measurements varies by up to a factor of three, depending upon the morphometric method used to determine \(z_{d}\) and \(z_{0}\).