BACKGROUND:As the catheter-based device closure of the patent foramen ovale (PFO) is expanding, novel devices aim to address the limitations of first-generation occluders (e.g. bulk, erosion, dislodgment). The second-generation device from Encore Medical (Eagan, MN, USA) features an articulating frame structure which allows the device to better conform to atrial anatomies, has lower disc thickness and metal mass/surface area, and is fully retrievable at any point in the procedure. The aim of the study was to evaluate the feasibility and safety of a novel low-profile, fully retrievable, Encore PFO closure device in the animal model. METHODS:Six swine underwent implantation of the novel PFO occluder under fluoroscopic and intra-cardiac echocardiography guidance and survived for 140 days. Interim transthoracic echocardiography (TTE) was conducted on Day 29. Following terminal angiography and TTE at 140 days, the hearts were subjected to gross and histopathologic analysis. RESULTS:All animals were successfully implanted and survived for 140 days. Interim TTE revealed proper device retention with no blood flow across the septum or thrombus in any of the animals. X-ray and pathology results showed preserved implant integrity with no fractures, and complete integration of the devices into the septum with complete re-endothelialization and nearly complete coverage by a mature, relatively thin neoendocardium. No surface fibrin deposition or thrombosis was reported. CONCLUSIONS:In the standard porcine model, device retention and biocompatibility remained favorable following structural and functional device modifications exemplified by the second-generation PFO occluder from Encore Medical, including marked reduction of metal mass.
ObjectivesAimed to evaluate the feasibility of deployment and healing response of a novel transcatheter left atrial appendage (LAA) occlusion device in the canine modelBackgroundLAA occlusion is proposed to reduce the risk of stroke in atrial fibrillation patientsMethodsTransseptal puncture and device deployment was guided under fluoroscopy and transesophageal echocardiography (TEE) in five dogs. First, a distal cylindrical bulb occluder was released and secured to the appendage wall with hooks. Subsequently, a proximal sail was unfolded, covering the LAA ostium. Rotational angiography, TEE, and histology outcomes were assessed 30 days following implantationResultsPre‐operative TEE revealed the mean diameter of the LAA ostium to be 17.2 ± 1.6 mm with a depth of 18.5 ± 1.7 mm. The landing zone for the distal bulb was measured to be 12.8 ± 1.3 mm. The mean bulb diameter at implant was 16.8 ± 1.8 mm. Post‐operative TEE showed adequate positioning and successful LAA occlusion with all implanted devices. Pericardial effusion requiring pericardiocentesis was seen in one animal following device implantation. At 30 days, TEE revealed full occlusion of all LAA ostia with the exception of a minimal peri‐device leak (<3 mm) observed in one animal. No pericardial effusion or device‐related thrombus formation was found at termination. Histological analysis confirmed circumferential occlusion of all appendages and complete neointimal coverage on the luminal aspect of the occluderConclusionThe percutaneous delivery of a novel self‐positioning LAA occlusion device is feasible and safe in a canine model. At 30 days, all devices displayed complete healing and occlusion of the LAA without any device related adverse events. © 2015 Wiley Periodicals, Inc.