The Swedish Water & Wastewater Association has operated a web-based system, VASS, for the collection and compilation of key data from the Swedish water utilities since 2003. The VASS system will now be expanded to include data on operation of individual wastewater treatment plants (WWTP). The objective is to provide performance indicators (PIs) for performance and economy and the use of resources such as energy, chemicals and manpower. A set of PIs has been developed that also includes explanatory factors to compensate for differences in the condition of operation between plants. This paper discusses the data required for the calculation of PI but also for explanatory factors, quality checks and for plant operation context. The discussion is based on the experiences from a test round with the participation of 24 WWTP.
Nine filter beds have been constructed in the Nordic countries, Denmark, Finland, Norway and Sweden. Filter beds consist of a septic tank followed by an aerobic pre-treatment biofilter and a subsequent saturated flow grass-covered filter. Thus, filter beds are similar to subsurface flow constructed wetlands with pre-treatment biofilters, but do not have wetland plants with roots submerged into the saturated filter. All saturated filters contain Filtralite®P, a light-weight expanded clay aggregate possessing high phosphorus sorption capacity. The filter bed systems showed stable and consistent performance during the testing period of 3 years. Removal of organic matter measured as biochemical oxygen demand (BOD) was >80%, total phosphorus (TP) >94% and total nitrogen (TN) ranged from 32 to 66%. Effluent concentrations of fecal indicator bacteria met the European bathing water quality criteria in all systems. One system was investigated for virus removal and somatic viruses were not detected in the effluent. The investigations revealed that the majority of the BOD and nitrogen removal occurred in the pre-treatment filters and the phosphorus and bacteria removal was more prominent in the saturated filters. The saturated filters could be built substantially smaller than the current design guidelines without sacrificing treatment performance. The used filter material met the Norwegian regulations for reuse in agriculture with respect to heavy metals, bacteria and parasites. When saturated with phosphorus, the light-weight aggregate, Filtralite®P used in the saturated bed is a suitable phosphorus fertilizer and additionally has a liming effect.
An analysis of the environmental effects and resource consumption by four systems for management of wastewater and organic household waste in a new city area have been performed, as follows: (1) conventional system complemented with advanced sludge treatment for phosphorus recovery, (2) blackwater system with urine diversion and food waste disposers, (3) blackwater system with food waste disposers and reverse osmosis, and (4) local wastewater treatment plant with nutrient recovery by using reverse osmosis. Substance-flow analysis and energy/exergy calculations were performed by using the software tool URWARE/ORWARE. Emissions were calculated and classified based on the impact categories global warming potential, acidification, and eutrophication, according to ISO 14042 (2000). The analysis also included nutrient recovery (i.e., the potential to use nutrients as a fertilizer). Depending on which aspects are prioritized, different systems can be considered to be the most advantageous.
The standard of wastewater management is high in Sweden. Around 90% of the population is connected to central wastewater treatment plants with high requirements of nutrients removal; however, still the problem with algae blooms in the Baltic Sea exists. The aim of the VeVa project was to develop a simple and user-friendly Excel-based model to support environmental decisions of how to select wastewater systems for housing areas where no central sewer system exists. The VeVa model deals with two types of environmental issues: substance flow analysis and energy analysis. Six system structures were studied for the transition area Lillängsdal in Värmdö municipality sorted in three categories: 1) on-site systems for single households; 2) local collective systems; 3) connection to central systems. All studied system structures, except for a Sand filter system, fulfilled the goals of reducing phosphorus and BOD7 according to Swedish guidelines for on-site systems in sensitive areas. All studied systems, except for the Sand filter system, have the potential to fulfil the Swedish National Environmental goal to recycle 60% phosphorus to productive land. The systems with central wastewater treatment plant and local wastewater treatment are the most energy efficient alternatives that also fulfil the requirements of discharges and environmental goals regarding phosphorus recycling.
Domestic wastewater from a new city district in Stockholm has been treated by an anaerobic membrane bioreactor (AMBR) followed by reverse osmosis (RO). The main objectives were to study the gas production, the reduction of organic matter and nutrient recovery. The AMBR was operated at 22 degrees C (equal to the average temperature in the influent) and a hydraulic retention time of 0.6 d. The results show that the reduction of organic matter, nitrogen and phosphorus over the AMBR was approximately 92, 9 and 9%, respectively. A stable gas production was registered throughout the evaluation period. The overall removal efficiency, i.e. including the RO, was > 99% for TOC, > 91% for Kj-N and about 99% for P. Adding a reverse osmosis (RO) unit to the AMBR makes it possible to produce a concentrated, nutrient rich product well suited for agricultural use. The quality of the concentrate is, in terms of nutrient concentration and heavy metal content, similar to source separated human urine, i.e. nitrogen content about 3 g N/L and < 2 mg Cd/kg.P. However, addition of acid is required to prevent precipitation/fouling of the RO. The total electricity use for operation for the system, including the RO-unit, is estimated to be 3-6 kWh/M-3.
PurposeThe purpose of the project was to evaluate and demonstrate new solutions for decreasing the discharges from on‐site wastewater treatment plants.Design/methodology/approachThe study evaluated several on‐site wastewater treatment plants. Seven of the investigated facilities were package plants, two were urine separating plants with large sand filters, two had storage tanks to collect wastewater separated from toilets and compact sand filters, and, finally, four had chemical precipitation in combination with large sand filters.FindingsAll of the systems have shown that they are able to remove more than 90 per cent of the phosphorus and more than 90 per cent of the organic matter. The sorting systems also give very low local emissions of nitrogen. To guarantee that the package plants perform well and manage to fulfil high reduction demands, there is a need for well functioning organisations for supervision and operation. The source separating systems require well‐informed and motivated users to achieve low discharges.Originality/valueThis study has been followed with great interest by national and local environmental authorities. Such ambitious evaluation of different on‐site wastewater treatment systems has never been done before in Sweden. The Swedish Environmental Protection Agency is expected to soon publish new demands for these systems. The results from the project have been an important input for the proposal of new national regulations.
Experiments with concentration of nutrients from source separated urine and reject water from digestion of sludge in sewage treatment plants (STP) have been performed in laboratory and pilot scale. The methods tested were membrane filtration with reverse osmosis (RO), evaporation, and precipitation of phosphorus and distillation of ammonia. In membrane filtration, pre-filtration with particle separation at 5-10 microm was enough to avoid clogging of the membranes. Separation of phosphorus (P), potassium (K) and sulphur (S) was almost 100%, while separation of nitrogen (N) was dependent on pH. The capacity of flux increased with temperature and pressure. In evaporation, all P, K and S were still in the concentrate, while pH had to be decreased to 4.5 to avoid significant loss of N. In precipitation and distillation, about 90% of P could be recovered from urine as magnesium ammonium phosphate (MAP) just by adding MgO. For the reject water pH was first increased by aeration to remove CO2. Ammonium can be distilled from the water phase after precipitation of MAP, without further increase of pH. At least 80-90% of N can be distilled in 5-10% of the total volume. The article also discusses the quality of different products, cost of separation, and energy and chemical demand.
In this document, a large number of mathematical models describing various physical, biological and chemical processes in a wastewater treatment plant are presented. In most cases, the models are fairly simple as they are inteded for steady-state simulations based on yearly averages of the influent wastewater charteristics. The combination of models forms a software tool namned URWARE (URban WAter REsearch model), which is a tool for substance flow analysis and energy calculations in wastewater treatment systems. All models are based on the MATLAB/Simulink platform. The different models can be combined in any fashion thereby creating various system structures that can be analysed and compared. The models keep track of numerous substances related to wastewater, such as organic substances, nutrients and to some extent heavy metals. Within all models the release of environmentally hazardous substances to water, soil and air are calculated. The results can be used as one (of many) information pathways for strategic decision making related to urban water systems. The individual models are described one by one and their behaviours are exemplified by simulation results. In many cases, comparisons with other available software models are given to validate (or at least make plausible) the results produced by the fairly simple URWARE models. Simulation results based on a combination of models into a complete wastewater treatment plant are also presented. However, details about the underlying theory and hypotheses on which the models are based cannot always be sufficiently described due to space limitations. Moreover, users should always be critical to any results predicted by models and not take them for granted simply because they have been calculated by a computer model. Knowledge about the real processes and comparisons with real data are imperative to evaluate whether the predicted results are reasonable or not. For the interested reader the complete source code to all models is included in an extensive appendix. A modelling task of this magnitude is never completed. The proposed models can always be further developed, improved and refined. Consequently, the models described in this document only represent the first version of the URWARE software. Many issues remain to be solved and further improvements to be done. However, it is the hope of the authors that the presented models are mature enough to be used, evaluated, modified and improved by other users outside the URWARE task group. (Less)
Different technologies for the treatment of wastewater from single houses have been evaluated by performing measurements at 14 treatment plants installed at different one-family houses located 35 km south-west of Stockholm. The technologies tested were selected in order to deliver high removal efficiencies with respect to organic matter, nitrogen and phosphorus. They also had to fulfil requirements concerning robustness, nutrient recycling, use of natural resources, economy, user-friendliness and hygiene. The systems can be divided into package plants, urine separating systems, blackwater separating systems and chemical precipitation as a supplement to sand filter beds. All of the systems were able to remove more than 90% of phosphorus and more than 90% of organic matter. Concerning package plants, it is necessary to have reliable dosing equipment and frequent checks to achieve long-term phosphorus removal. The source separation systems require well-informed and motivated users to achieve desirable removal efficiency. Sorting systems seem to be superior with respect to nitrogen removal, even though some of the package plants gave nitrogen removal above 50% during long periods of operation.
Using a system analysis approach compares different systems for handling and treatment of toilet waste and organic household waste. Design issues considered are source separation of urine, use of vacuum toilets and advanced nutrient recovery processes such as Reverse Osmosis (RO). All of the studied systems have low emissions of eutrophy ing compounds. Other environmental effects are mainly related to the amount of exergy used at each system. Source separating of urine is favourable if only a moderate (50 - 70 %) recycling potential for nutrients such as N and K is required. However, if hi gher recycling potential is required systems using nutrient recovery processes such as RO/evaporator are probably to prefer. For vacuum sy stems, the maximum amounts of flush water must be below 10 lit/p,d to make them reasonable efficient in terms of exergy consumption. The low-flush systems are less sensitive to the use of flush water in terms of exergy consumption. (Less)
In an exergy analysis, the actual consumption of resources in physical and chemical processes is calculated. Energy and chemical elements are not consumed in the processes--they are only transformed into other forms with lower quality. The principals of exergy analysis are illustrated by comparing different wastewater treatment systems for nutrient recovery. One system represents an end-of-pipe structure, whereas other systems include source separation of grey water, black water, and urine. The exergy flows analysed in this paper are those related to management and treatment of organic matter and nutrients. The study shows that the total exergy consumption is lowest for the system with source separation of urine and faeces and greatest for the conventional wastewater treatment system complemented by processes for nutrient recovery.
In this paper, two fundamentally different urban wastewater systems are assessed from an environmental impact perspective. One system represents a centralised, high-tech, end-of-pipe structure whereas the second system is primarily based on source-separation strategies. Using material flow analysis in combination with evaluation methods based on life-cycle assessment the systems are evaluated by means of simulation and the results are discussed. A set of priority indicators for environmental assessments of urban water systems is suggested and applied in the analysis. Energy issues are also commented upon. The main intent of the paper is to present the principles of this type of assessment rather than detailed numbers for all possible environmental effects and hazardous substances emitted to air, water and soil. It represents one of several building blocks for a future multi-criteria decision-support system to evaluate urban water management from a sustainability perspective.