Background Viscoelastometric haemostatic assays (VHA) give rapid information on coagulation status, allowing individualised resuscitation. Methods This paper compares outcomes from two observational studies of postpartum haemorrhage (PPH) in the same institution, before and after practice changed from fixed ratio empirical transfusion of coagulation products with laboratory coagulation testing to VHA-guided fibrinogen replacement incorporated into an enhanced PPH care bundle.In both studies, all blood samples were taken near 1000 mL qualitative blood loss (QBL). In Study One, QBL started once PPH was identified, and resuscitation with coagulation blood products was empirical or based on laboratory tests of coagulation. In Study Two, QBL started at delivery and VHA was used to guide fibrinogen replacement if FIBTEM A5 was <12 mm (Claus fibrinogen ≤2 g/L) or to withhold coagulation products if FIBTEM A5 was >12 mm. Results Improved PPH outcomes were observed in Study Two, with rates of measured blood loss ≥2500 mL, ≥4 units red blood cell (RBC) transfusion, fresh frozen plasma transfusion and ≥8 units of any blood product transfusion all reduced (P <0.01). Clinically significant improvements occurred in women with fibrinogen <2 g/L at study entry, where the proportion of women who received ≥4 units RBC transfusion fell from 67% in Study One to 0% in Study Two (P =0.0007). Conclusions These results suggest that use of VHA as part of an early bundle of PPH care targeting fibrinogen <2 g/L with fibrinogen concentrate reduces PPH progression. The greatest benefit was seen when fibrinogen levels <2 g/L at first testing.
(Int J Obstet Anes. 2022;49:103238) Viscoelastometric hemostatic assays, such as rotational thromboelastometry (ROTEM), offer rapid, point-of-care identification of coagulopathy during postpartum hemorrhage (PPH). Previous studies investigating the use of ROTEM have used a Delta ROTEM device. This study investigates the use of the ROTEM Sigma device, identifying the sensitivity, specificity, and positive or negative predictive values in patients with PPH.
Introduction: Postpartum hemorrhage (PPH) is the leading cause of maternal morbidity in the UK. Visual estimation of blood loss is unreliable yet remains common practice. As part of a national quality improvement project to improve care during PPH, standardized, quantitative measurement of blood loss (QBL) for all deliveries was introduced into a tertiary obstetric unit in Cardiff, Wales. Methods: Retrospective analysis of 875 consecutive maternities between December 2017 and February 2018 was undertaken. Of these, 372 mothers had both pre- and post-partum hemoglobin (Hb) were recorded. Regression analyses were performed to investigate the relationship between change in Hb adjusted for red cell transfusion and QBL. Results: The correlation coefficient between QBL and adjusted change in Hb for all deliveries (n = 372) was 0.57. This corresponded to an estimated fall of adjusted change in Hb of 15.3 g/L (95% CI: 13.1, 17.6) per 1000 mL blood loss. Discussion: QBL has been shown to be reliable across all maternity settings, with reproducible results in theater and delivery rooms (on the obstetric unit and alongside midwifery-led unit). QBL is moderately correlated with adjusted change in Hb for all volumes of bleeding and gives clinicians more accurate knowledge of blood loss than visual estimation. This low-cost, low-fidelity intervention can influence the timely escalation of clinical care and therefore patient outcome.
BACKGROUND:The TEG 6s is an automated cartridge-based device with limited description of use in obstetric haemorrhage. The aim of this analysis was to describe the utility of TEG 6s in identifying abnormal laboratory results of coagulation and platelet count, and inform an interventional treatment algorithm for postpartum haemorrhage. METHODS:A prospective observational cohort study of 521 women with moderate to severe obstetric haemorrhage (>1000 mL blood loss), including 372 women with at least one TEG 6s test. A non-pregnant control group was used for reference. TEG 6s test parameters Citrated Functional Fibrinogen (CFF), Citrated Kaolin TEG (CK) and Citrated Rapid TEG (CRT) were compared with paired laboratory tests of fibrinogen, PT/aPTT and platelet count, obtained during haemorrhage. RESULTS:Among 456 TEG 6s tests, 389 were matched with laboratory coagulation results. The receiver operator characteristic area-under-the-curve (95% CI) for CFF amplitude by 10 min to detect Clauss fibrinogen ≤2 g/L was 0.95 (0.91 to 0.99) (P<0.0001, sensitivity 0.74 and specificity 0.97 at ≤17 mm). False positives had median (IQR) Clauss fibrinogen of 2.4 (2.3-2.7) g/L. The CK-R time had some utility for detecting prolonged PT/aPTT, however a threshold for fresh frozen plasma transfusion was not established. A CRT maximum amplitude <57 mm, when CFF was ≥15 mm, identified four of eight samples with platelet count <75 × 109/L. CONCLUSION:The TEG 6s CFF can be used to identify low fibrinogen during obstetric haemorrhage. A value to identify transfusion thresholds for PT/aPTT and platelets was not established, and laboratory results should continue to be used.