PurposeTo summarize dose trends from 1980-2020 for 19,651 U.S. radiologic technologists who reported assisting with fluoroscopically-guided interventional procedures (FGIP), overall and by work history characteristics.MethodsWe summarized 762,310 annual personal dose equivalents at a 10 mm-reference depth (“doses”) during 1980-2020 for 43,823 participants of the U.S. Radiologic Technologists (USRT) cohort who responded to work history questionnaires administered during 2012-2014. This population included 19,651 technologists who reported assisting with FGIP (≥1 time per month for ≥12 consecutive months) at any time during the study period. We estimated doses corresponding to assistance with FGIP by proximity to patients, monthly procedure frequency, and procedure type. We used box plots and summary statistics (e.g., median, percentiles) to describe annual doses and dose trends.ResultsMedian annual dose corresponding to assistance with FGIP was 0.65 mSv, [interquartile range (IQR)=0.60-1.40; 95th percentile=6.80]. Higher occupational doses with wider variability were associated with close proximity to patients during assistance with FGIP (median=1.20 mSv; IQR=0.60-4.18; 95th percentile=12.66), performing ≥20 FGIP per month (median=0.75 mSv; IQR=0.60, 2.40; 95th percentile=9.44), and assisting with high-dose FGIP (median=0.70; IQR=0.60, 1.90; 95th percentile=8.30).ConclusionOccupational doses corresponding to assistance with FGIP were generally low but varied with exposure frequency, procedure type, and proximity to patients. These results highlight the need for vigilant dose monitoring, radiation safety training, and proper protective equipment.
As part of translational research projects, mice may be irradiated on radiobiology platforms such as the one at the ARRONAX cyclotron. Generally, these platforms do not feature an integrated imaging system. Moreover, in the context of ultra-high dose-rate radiotherapy (FLASH-RT), treatment planning should consider potential changes in the beam characteristics and internal movements in the animal.A patient-like set-up and methodology has been implemented to ensure target coverage during conformal irradiations of the brain, lungs and intestines. In addition, respiratory cycle amplitudes were quantified by fluoroscopic acquisitions on a mouse, to ensure organ coverage and to assess the impact of respiration during FLASH-RT using the 4D digital phantom MOBY. Furthermore, beam incidence direction was studied from mice µCBCT and Monte Carlo simulations. Finally,in vivodosimetry with dose-rate independent radiochromic films (OC-1) and their LET dependency were investigated.The immobilization system ensures that the animal is held in a safe and suitable position. The geometrical evaluation of organ coverage, after the addition of the margins around the organs, was satisfactory. Moreover, no measured differences were found between CONV and FLASH beams enabling a single model of the beamline for all planning studies. Finally, the LET-dependency of the OC-1 film was determined and experimentally verified with phantoms, as well as the feasibility of using these filmsin vivoto validate the targeting.The methodology developed ensures accurate and reproducible preclinical irradiations in CONV and FLASH-RT without in-room image guidance in terms of positioning, dose calculation andin vivodosimetry.
The exponential growth in the use of nuclear medicine procedures represents a general radiation safety concern and stresses the need to monitor exposure levels and radiation-related long term health effects in NM patients. In the current study, following our previous work on NCINM version 1 based on the UF/NCI hybrid phantom series, we calculated a comprehensive library of S values using the ICRP reference pediatric and adult voxel phantoms and established a library of biokinetic data from multiple ICRP Publications, which were then implemented into NCINM version 2. We calculated S values in two steps: calculation of specific absorbed fraction (SAF) using a Monte Carlo radiation transport code combined with the twelve ICRP pediatric and adult voxel phantoms for a number of combinations of source and target region pairs; derivation of S values from the SAFs using the ICRP nuclear decay data. We also adjusted the biokinetic data of 105 radiopharmaceuticals from multiple ICRP publications to match the anatomical description of the ICRP voxel phantoms. Finally, we integrated the ICRP phantom-based S values and adjusted biokinetic data into NCINM version 2. The ratios of cross-fire SAFs from NCINM 2 to NCINM 1 for the adult phantoms varied widely from 0.26 to 5.94 (mean = 1.24, IQR = 0.77–1.55) whereas the ratios for the pediatric phantoms ranged from 0.64 to 1.47 (mean = 1.01, IQR = 0.98–1.03). The ratios of absorbed dose coefficients from NCINM 2 over those from ICRP publications widely varied from 0.43 (colon for 99m Tc-ECD) to 2.57 (active marrow for 99m Tc-MAG3). NCINM 2.0 should be useful for dosimetrists and medical physicists to more accurately estimate organ doses for various nuclear medicine procedures.
Purpose The ARRONAX cyclotron facility offers the possibility to deliver proton beams from low to ultra-high dose rates (UHDR). As a good control of the dosimetry is a prerequisite of UHDR experimentations, we evaluated in different conditions the usability and the dose rate dependency of several radiochromic films commonly used for dosimetry in radiotherapy. Methods We compared the dose rate dependency of three types of radiochromic films: GAFchromic (TM) EBT3 and GAFchromic (TM) EBT-XD (Ashland Inc., Wayne, NJ, USA), and OrthoChromic OC-1 (OrthoChrome Inc., Hillsborough, NJ, USA), after proton irradiations at various mean dose rates (0.25, 40, 1500, and 7500 Gy/s) and for 10 doses (2-130 Gy). We also evaluated the dose rate dependency of each film considering beam structures, from single pulse to multiple pulses with various frequencies. Results EBT3 and EBT-XD films showed differences of response between conventional (0.25 Gy/s) and UHDR (7500 Gy/s) conditions, above 10 Gy. On the contrary, OC-1 films did not present overall difference of response for doses except below 3 Gy. We observed an increase of the netOD with the mean dose rate for EBT3 and EBT-XD films. OC-1 films did not show any impact of the mean dose rate up to 7500 Gy/s, above 3 Gy. No difference was found based on the beam structure, for all three types of films. Conclusions EBT3 and EBT-XD radiochromic films should be used with caution for the dosimetry of UHDR proton beams over 10 Gy. Their overresponse, which increases with mean dose rate and dose, could lead to non-negligible overestimations of the absolute dose. OC-1 films are dose rate independent up to 7500 Gy/s in proton beams. Films response is not impacted by the beam structure. A broader investigation of the usability of OC-1 films in UHDR conditions should be conducted at intermediate and higher mean dose rates and other beam energies.
During ultra-high dose rate (UHDR) external radiation therapy, healthy tissues appear to be spared while tumor control remains the same compared to conventional dose rate. However, the understanding of radiochemical and biological mechanisms involved are still to be discussed. This study shows how the hydrogen peroxide (H2O2) production, one of the reactive oxygen species (ROS), could be controlled by early heterogenous radiolysis processes in water during UHDR proton-beam irradiations. Pure water was irradiated in the plateau region (track-segment) with 68 MeV protons under conventional (0.2 Gy/s) and several UHDR conditions (40 Gy/s to 60 kGy/s) at the ARRONAX cyclotron. Production of H2O2 was then monitored using the Ghormley triiodide method. New values of GTS(H2O2) were added in conventional dose rate. A substantial decrease in H2O2 production was observed from 0.2 to 1.5 kGy/s with a more dramatic decrease below 100 Gy/ s. At higher dose rate, up to 60 kGy/s, the H2O2 production stayed stable with a mean decrease of 38% ± 4%. This finding, associated to the decrease in the production of hydroxyl radical (•OH) already observed in other studies in similar conditions can be explained by the well-known spur theory in radiation chemistry. Thus, a two-step FLASH-RT mechanism can be envisioned: an early step at the microsecond scale mainly controlled by heterogenous radiolysis, and a second, slower, dominated by O2 depletion and biochemical processes. To validate this hypothesis, more measurements of radiolytic species will soon be performed, including radicals and associated lifetimes.
PURPOSE:Since the 1980s, both the incidence of differentiated thyroid cancer (DTC) and use of radioactive iodine (RAI) treatment increased markedly. RAI has been associated with an increased risk of leukemia, but risks of second solid malignancies remain unclear. We aimed to quantify risks of second malignancies associated with RAI treatment for DTC in children and young adults, who are more susceptible than older adults to the late effects of radiation.METHODS:Using nine US SEER cancer registries (1975-2017), we estimated relative risks (RRs) for solid and hematologic malignancies associated with RAI (yes v no or unknown) using Poisson regression among ≥ 5- and ≥ 2-year survivors of nonmetastatic DTC diagnosed before age 45 years, respectively.RESULTS:Among 27,050 ≥ 5-year survivors (median follow-up = 15 years), RAI treatment (45%) was associated with increased risk of solid malignancies (RR = 1.23; 95% CI, 1.11 to 1.37). Risks were increased for uterine cancer (RR = 1.55; 95% CI, 1.03 to 2.32) and nonsignificantly for cancers of the salivary gland (RR = 2.15; 95% CI, 0.91 to 5.08), stomach (RR = 1.61; 95% CI, 0.70 to 3.69), lung (RR = 1.42; 95% CI, 0.97 to 2.08), and female breast (RR = 1.18; 95% CI, 0.99 to 1.40). Risks of total solid and female breast cancer, the most common cancer type, were highest among ≥ 20-year DTC survivors (RRsolid = 1.47; 95% CI, 1.24 to 1.74; RRbreast = 1.46; 95% CI, 1.10 to 1.95). Among 32,171 ≥ 2-year survivors, RAI was associated with increased risk of hematologic malignancies (RR = 1.51; 95% CI, 1.08 to 2.01), including leukemia (RR = 1.92; 95% CI, 1.04 to 3.56). We estimated that 6% of solid and 14% of hematologic malignancies in pediatric and young adult DTC survivors may be attributable to RAI.CONCLUSION:In addition to leukemia, RAI treatment for childhood and young-adulthood DTC was associated with increased risks of several solid cancers, particularly more than 20 years after exposure, supporting the need for long-term surveillance of these patients.
Daphnee Villoing*, R Craig Yoder, Christopher Passmore, Marie-Odile Bernier, Martha Linet, Cari M Kitahara. Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD, USA Minor Outlying Islands; Consultant, Weddington, NC, USA Minor Outlying Islands; Landauer, Inc., Glenwood, IL, USA Minor Outlying Islands; Institut de Radioprotection et de Sureté Nucléaire, Fontenay-aux-roses, France
Proton therapy (PRT) is an irradiation technique that aims at limiting normal tissue damage while maintaining the tumor response. To study its specificities, the ARRONAX cyclotron is currently developing a preclinical structure compatible with biological experiments. A prerequisite is to identify and control uncertainties on the ARRONAX beamline, which can lead to significant biases in the observed biological results and dose–response relationships, as for any facility. This paper summarizes and quantifies the impact of uncertainty on proton range, absorbed dose, and dose homogeneity in a preclinical context of cell or small animal irradiation on the Bragg curve, using Monte Carlo simulations. All possible sources of uncertainty were investigated and discussed independently. Those with a significant impact were identified, and protocols were established to reduce their consequences. Overall, the uncertainties evaluated were similar to those from clinical practice and are considered compatible with the performance of radiobiological experiments, as well as the study of dose–response relationships on this proton beam. Another conclusion of this study is that Monte Carlo simulations can be used to help build preclinical lines in other setups.
Background Occupational doses to most medical radiation workers have declined substantially since the 1950s because of improvements in radiation protection practices. However, different patterns may have emerged for radiologic technologists working with nuclear medicine because of the higher per-procedure doses and increasing workloads. Purpose To summarize annual occupational doses during a 36-year period for a large cohort of U.S. radiologic technologists and to compare dose between general radiologic technologists and those specializing in nuclear medicine procedures. Materials and Methods Annual personal dose equivalents (referred to as doses) from 1980 to 2015 were summarized for 58 434 (62%) participants in the U.S. Radiologic Technologists (USRT) cohort who responded to the most recent mailed work history survey (years 2012-2014) and reported never regularly performing interventional procedures. Doses were partitioned according to the performance of nuclear medicine (yes or no, frequency, procedure type) by calendar year. Annual dose records were described by using summary statistics (eg, median and 25th and 75th percentiles). Results Median annual doses related to performance of general radiologic procedures decreased from 0.60 mSv (interquartile range [IQR], 0.10-1.9 mSv) in 1980 to levels below the limits of detection by 2015, whereas annual doses related to performance of nuclear medicine procedures remained relatively high during this period (median, 1.2 mSv; IQR, 0.12-3.0 mSv). Higher median annual doses were associated with more frequent (above vs below the median) performance of diagnostic nuclear medicine procedures (≥35 vs <35 times per week; 1.6 mSv [IQR, 0.30-3.3 mSv] and 0.9 mSv [IQR, 0.10-2.6 mSv]). Higher and more variable annual doses were associated with more frequent performance of cardiac nuclear medicine (≥10 times per week) and PET (nine or more times per week) examinations (median, 1.6 mSv [IQR, 0.30-2.2 mSv] and 2.2 mSv [IQR, 0.10-4.6 mSv], respectively). Conclusion Annual doses to U.S. radiologic technologists performing general radiologic procedures declined during a 36-year period. However, consistently higher and more variable doses were associated with the performance of nuclear medicine procedures, particularly cardiac nuclear medicine and PET procedures. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Mettler and Guiberteau in this issue.
Nuclear medicine is the second largest source of medical radiation exposure to the general population after computed tomography imaging. Informed decisions regarding the use of nuclear medicine procedures require a better understanding of the magnitude of radiation dose and associated health risks. However, existing model-based organ dose estimation tools rely on simplified human anatomy models or commercial programs. Therefore, we developed a publicly-available dose calculation tool based on more sophisticated human anatomy models. We calculated a comprehensive library of photon and electron specific absorbed fractions (SAF) for multiple combinations of source and target regions within a series of pediatric and adult computational human phantoms matching the International Commission on Radiological Protection (ICRP)'s reference data, combined with a Monte Carlo radiation transport code. Then, we derived a library of S values from these SAFs and the nuclear decay data from ICRP Publication 107. Finally, we created a graphical user interface, named National Cancer Institute Dosimetry System for Nuclear Medicine (NCINM), to facilitate the dosimetry process. Approximately 13 million S values were derived from 2 million SAFs computed in this work. Comprehensive comparisons were conducted at different steps of the dosimetry chain with data available in software OLINDA/EXM 1.0 and IDAC 2.1. For instance, median ratios of photon self-absorption SAFs available from OLINDA/EXM 1.0 and IDAC 2.1 to those calculated in this study were 1.3 (interquartile range = 1.1-1.6) and 1.0 (interquartile range = 0.98-1.0), respectively. SAF differences between NCINM and OLINDA/EXM 1.0 were explained by the large inter-phantom anatomical variability. Our results illustrate the importance of realistic human anatomy models for use in dosimetry software. More phantoms and radionuclides, as well as a biokinetic module, will soon be added. Applications of the NCINM program include computation of absorbed doses for use in radiation epidemiologic studies and patient dose monitoring in nuclear medicine.