Correction for ‘Immunoassay-aptasensor for the determination of tumor-derived exosomes based on the combination of magnetic nanoparticles and hybridization chain reaction’ by Hua Zhang et al. , RSC Adv. , 2021, 11 , 4983–4990, https://doi.org/10.1039/D0RA10159A.
Correction for 'Immunoassay-aptasensor for the determination of tumor-derived exosomes based on the combination of magnetic nanoparticles and hybridization chain reaction' by Hua Zhang et al., RSC Adv., 2021, 11, 4983-4990, https://doi.org/10.1039/D0RA10159A.
A fluorescence aptasensor based on taking the advantage of the combination of magnetic nanoparticles (MNPs), terminal deoxynucleotidyl transferase (TdT), and CRISPR/Cas12a was developed for the determination of nasopharyngeal carcinoma (NPC)-derived exosomes. The MNPs can eliminate background interference due to their magnetic separation capability. TdT can form an ultra-long polynucleotide tail which can bind with multiple crRNA, generating a signal amplification effect. The trans-cleavage activity of CRISPR/Cas12a can be specifically triggered via the crRNA binding with DNA, resulting in the bi-labeled DNA reporter with fluorophore and quencher being cleaved. The excitation wavelength of the fluorescence spectra was 490 nm. Fluorescence spectra with emission wavelengths ranging from 511 to 600 nm were collected. Under the optimization condition, the fabricated fluorescence aptasensor for NPC-derived exosome determination exhibited excellent sensitivity and specificity, with the linear range between 500 to 5 × 104 particles mL−1 and the limit of detection of 100 particles mL−1. It can be used for the determination of NPC-derived exosomes in clinical samples, which has a considerable clinical potential and prospect.
Correction for ‘A fluorescent biosensor for cardiac biomarker myoglobin detection based on carbon dots and deoxyribonuclease I-aided target recycling signal amplification’ by Jishun Chen et al., RSC Adv., 2019, 9, 4463–4468, https://doi.org/10.1039/C8RA09459D.
Correction for 'Ultrasensitive fluorescent aptasensor for CRP detection based on the RNase H assisted DNA recycling signal amplification strategy' by Zhongzhi Liu et al., RSC Adv., 2019, 9, 11960-11967, https://doi.org/10.1039/C9RA01352K.
The detection of tumor-related exosomes is of great significance. In this work, a fluorescence aptasensor was designed for the determination of tumor-related exosomes based on the capture of magnetic nanoparticles (MNPs) and specific recognition of an aptamer. MNPs were used as substrates to capture the exosomes by modifying the CD63 antibody on the MNP surface. Probe 1 consists of PDL-1 aptamer sequence and a section of other sequences. PDL-1 expression was observed on the surface of exosomes; the aptamer of PDL-1 could combine with PDL-1 with high affinity. Thus, the immunoassay-type compounds of "MNPs-exosomes-probe 1" were formed. The other section of probe 1 triggered the HCR with probe 2 and probe 3 and formed the super-long dsDNA. The addition of GelRed resulted in the generation of an amplified fluorescence signal. The proposed design demonstrated a good linearity with the exosome concentration ranging from 300 to 10(7) particles per mL and with a low detection limit of 100 particles per mL. This aptasensor also exhibited high specificity for tumor-related exosomes, and was successfully applied in biological samples.
We developed a high-efficiency microfluidic chip for extracting exosomes from human plasma. We collected peripheral blood from normal human, designed and fabricated a microfluidic chip based on nanoporous membrane and agarose gel electrophoresis to isolate exosomes. The extracted exosomes were characterized by transmission electron microscopy, nanosight and Western blotting, the morphology, concentration and particle size of exosomes were identified and analyzed. Meanwhile, we used ultracentrifugation and microfluidic chip to isolate exosomes separately. The particle size and concentration of the exosomes extracted by two methods were compared and analyzed, and their respective extraction efficiency was discussed. Finally, the expression level of miRNA-21 in exosomes was analyzed by RT-PCR. The microfluidic chip isolated (in 1 hour) high-purity exosomes with size ranging from 30-200 nm directly from human plasma, allowing downstream exosomal miRNA analysis. By comparing with ultracentrifugation, the isolation yield of microfluidic chip was 3.80 times higher than ultracentrifugation when the volume of plasma sample less than 100 μL. The optimized parameters for exosome isolation by gel electrophoresis microfluidic chip were: voltage: 100 V; concentration of agarose gel: 1.0%; flow rate of injection pump: 0.1 mL/h. The gel electrophoresis microfluidic chips could rapidly and efficiently isolate the exosomes, showing great potential in the research of exosomes and cancer biomarkers.
Purpose Based on DNase I and reduced graphene oxide (rGO)-magnetic silicon microspheres (MNPS), a highly sensitive and selective fluorescent probe for the detection of PD-L1 was developed. Design/methodology/approach Here °C we present a feasibility of biosensor to detection of PD-L1 in lung tumors plasma. In the absence of PD-L1°C the PD-L1 aptamer is absorbed on the surface of graphene oxide modified magnetic nanoparticles °8rGO-MNPS°9 and leading to effective fluorescence quenching. Upon adding PD-L1°C the aptamer sequences could be specifically recognized by PD-L1 and the aptamer/PD-L1 complex is formed°C resulting in the recovery of quenched fluorescence. Findings This sensor can detect PD-L1 with a linear range from 100 pg mL−1 to 100 ng mL−1, and a detection limit of 10 pg•m−1 was achieved. Originality/value This method provides an easy and sensitive method for the detection of PD-L1 and will be beneficial to the early diagnosis and prognosis of tumors.
We have developed an ultrasensitive and highly specific electrochemical sensing platform for the detection of cardiac troponin I (cTnI), a recognized biomarker for the diagnosis of acute myocardial infarction (AMI) and related cardiovascular diseases (CVDs). This strategy is based on the assists of terminal deoxynucleotidyl transferase (TdT)-mediated signal amplification and the specific recognition between cTnI and the aptamer of cTnI. In this experiment, we prepared a gold electrode that modified with probe 2 (P2), in the presence of cTnI, the aptamer of cTnI that in probe 1 (P1)/aptamer complexes bond with cTnI specifically and release the free P1. P1 would bind with P2, resulting in the formation of 3'-OH of DNA. In the presence of terminal deoxynucleotidyl transferase (TdT) and dTTP, TdT mediated P1 to extend and formed the structure of poly T. Methylene blue (MB)-poly A hybridized with the extended poly T and generated an electrochemical signal. The detection limit can be as low as 40 pg mL-1. This sensor was also successfully applied to the detection of cTnI in numerous spiked biological samples, and it can be a great reference for the clinical diagnosis, prognosis, and treatment of CVDs and AMI.
Carcinoembryonic antigen (CEA), serves as a broad-spectrum tumor marker, and plays an important role in reflecting the existence, therapeutic evaluation, development, monitoring and prognosis of many types of cancer. An electrochemical aptasensor was designed for CEA detection based on toehold-aided DNA recycling. A partially hybridized Probe-4 (i.e. P2/P3/P4) was self-assembled on the surface of a gold electrode serving as the sensing platform. For CEA detection, CEA can bind with aptamer and free probe-1 (P1) can hybridize with P4, triggering toehold-aided DNA recycling. This enables the hybridization of more probe-5 (P5) (labeled with methylene blue (MB)) with P4, causing more methylene blue (MB) to be brought close to the electrode surface. An amplified current signal was thus generated due to more MB in the electrode surface. The proposed design showed good linearity between current response and log CEA concentration ranging from 0.1 to 50 ng.mL(-1), with a detection limit of 20 pg mL(-1). This aptasensor also showed high specificity for CEA detection, and was successfully used in spiked biological samples. (C) 2020 Elsevier B.V. All rights reserved.
An aptamer-based method for the ultrasensitive fluorescence detection of C-reactive protein (CRP) was developed using the ribonuclease H (RNase H) assisted DNA recycling signal amplification strategy. In this assay, CRP can specifically bind to the aptamer of CRP and the DNA chain of P1 is released from the aptamer/P1 (Ap/P1) complexes. After the addition of the fluorescence labeled (5-FAM) RNA, P1 hybridizes with fluorescence labeled RNA to form a P1/RNA double strand. When RNase H is added, the RNA with fluorescence labeling in the double strand is specifically cut into nucleotide fragments, which cannot be adsorbed on the surface of the GO, so as to generate a fluorescence signal. In the absence of CRP, fluorescence labeled RNA cannot hybridize with P1 to form double strands, which is able to directly adsorb on the surface of GO, resulting in no fluorescence signal. The detection limit is as low as 0.01 ng mL-1, with a linear dynamic range from 50 pg mL-1 to 100 ng mL-1. This sensor is able to detect CRP in spiked human serum, urine and saliva. Thus, it shows a great application prospect in disease diagnosis and prognosis.
A sensitive biosensor using carbon dots and deoxyribonuclease I-aided target recycling signal amplification has been developed to detect myoglobin (MB), which is an important cardiac biomarker and plays a major role in the diagnosis of acute myocardial infarction (AMI). Here, in the absence of MB, the MB aptamer (Ap) is absorbed on the surface of carbon dots (CDs) through π-π stacking interactions, resulting in quenching of the fluorescent label by forming CD-aptamer complexes. Upon adding MB, the Ap sequences could be specifically recognized by MB, leading to the recovery of quenched fluorescence. Thus, quantitative evaluation of MB concentration has been achieved in a broad range from 50 pg mL-1 to 100 ng mL-1, and the detection limit is as low as 20 pg mL-1. This strategy is capable of specific and sensitive detection of MB in human serum, urine, and saliva and can be used for the diagnosis of AMI in the future.