Patients with fall and head strike are commonly assessed in the emergency department (ED), and discharged into care of their primary care physicians (PCPs) if spinal cord injury is excluded clinically or radiologically. We present the case of 84-year-old man, who sustained a fall with head strike, and was cleared of spinal cord injury. He later presented to his PCP with progressive upper limb weakness, requiring urgent surgical decompression. PCPs are well-placed to catch such patients and prevent morbidity and mortality. We advocate clear communication between ED and the PCP to ensure continuity from hospital to community.
Background: Titanium pedicle screw fixation complicates postoperative care in patients with spinal neoplasms due to postoperative imaging artefacts and dose perturbation. This study aims to measure the benefits of using carbon fiber/polyetheretherketone (CF/PEEK) pedicle fixation compared to titanium in postoperative imaging, radiotherapy planning and delivery for spinal neoplasms treated with conventional external beam radiotherapy with a commercial treatment planning system. Methods: The properties of CF/PEEK pedicle fixation systems were compared to titanium in radiotherapy dose planning accuracy and postoperative computed tomography (CT) image quality. Dose profiles through the screw, tulip and longitudinal axis of the screw were acquired with radiochromic films and compared to a collapsed cone algorithm simulation, to measure dose agreement. The image quality of postoperative CTs were compared by defining four regions of interest around the vertebrae and screws in water phantom models and previous planning CTs, and comparing calculated artefact indexes (AIs). Results: CF/PEEK screws have non-inferior dosimetric prediction accuracy up to 50 mm beneath the screw for collapsed-cone algorithm planning systems. There is a statistically significant reduction in the absolute difference between calculated and measured dose at a depth of 2 mm beneath the screw. There is minimal attenuation with CF/PEEK relative to the surrounding dose, extending to 50 mm beneath the screw. There is a statistically significant improvement in CT imaging quality with reduced AIs in CF/PEEK fixation compared to titanium in both model and patient CT plans. Conclusions: CF/PEEK pedicle fixation can provide benefits in postoperative imaging and photon radiotherapy planning and delivery to patients with spinal neoplasms.
Background: Musculoskeletal disorders can contribute to injurious falls and incur significant societal and healthcare burdens. Identification of fallers from non-fallers through wearable-based gait analysis can facilitate timely intervention to assist mobility and prevent falls whilst improving care and attention for high fall-risk patients. In this study, we use wearable sensor-based gait analysis to introduce a novel variable to assess walking stability in fallers and non-fallers - the Walking Orientation Randomness Metric. The WORM score quantifies the stability, or 'figure-of-eight' motion of a subject's trunk during walking as an indicator of a falls-predictive (pathological) gait. Methods: WORM is calculated as the 'figure-of-eight' oscillation mapped out in the transverse-plane by the upper body's centre-point during a walking bout. A sample of patients presenting to the Prince of Wales Hospital (Sydney, Australia) with a primary diagnosis of "falls for investigation" and age-matched healthy controls (non-fallers) from the community were recruited. Participants were fitted at the sternal angle with the wearable accelerometer, MetaMotionC (Mbientlab Inc., USA) and walked unobserved (at self-selected pace) for 5-50 m along an obstacle-free, carpeted hospital corridor. Results: Participants comprised of 16 fallers (mean age: 70 +/- 17) and 16 non-fallers (mean age: 70 +/- 9) based on a recent fall(s) history. The (median) WORM score was 17-fold higher (p < 0.001) in fallers (3.64 cm) compared to non-fallers (0.21 cm). ROC curve analyses demonstrate WORM can discriminate fallers from non-fallers (AUC = 0.97). Diagnostic analyses (cut-off > 0.51 cm) show high sensitivity (88%) and specificity (94%). Conclusion: In this pilot study we have introduced the WORM score, demonstrating its discriminative performance in a preliminary sample size of 16 fallers. WORM is a novel gait metric assessing walking stability as measured by truncal way during ambulation and shows promise for objective and clinical evaluation of fallers.
BACKGROUND:Wearable accelerometer-containing devices have become a mainstay in clinical studies which attempt to classify the gait patterns in various diseases. A gait profile for lumbar spinal stenosis (LSS) has not been developed, and no study has validated a simple wearable system for the clinical assessment of gait in lumbar stenosis. This study identifies the changes to gait patterns that occur in LSS to create a preliminary disease-specific gait profile. In addition, this study compares a chest-based wearable sensor, the MetaMotionC© device and inertial measurement unit python script (MMC/IMUPY) system, against a reference-standard, videography, to preliminarily assess its accuracy in measuring the gait features of patients with LSS.METHODS:We conduct a cross-sectional observational study examining the walking patterns of 25 LSS patients and 33 healthy controls. To construct a preliminary disease-specific gait profile for LSS, the gait patterns of the 25 LSS patients and 25 healthy controls with similar ages were compared. To assess the accuracy of the MMC/IMUPY system in measuring the gait features of patients with LSS, its results were compared with videography for the 21 LSS and 33 healthy controls whose walking bouts exceeded 30 m.RESULTS:Patients suffering from LSS walked significantly slower, with shorter, less frequent steps and higher asymmetry compared to healthy controls. The MMC/IMUPY system had >90% agreement with videography for all spatiotemporal gait metrics that both methods could measure.CONCLUSIONS:The MMC/IMUPY system is a simple and feasible system for the construction of a preliminary disease-specific gait profile for LSS. Before clinical application in everyday living conditions is possible, further studies involving the construction of a more detailed disease-specific gait profile for LSS by disease severity, and the validation of the MMC/IMUPY system in the home environment, are required.
Objectives: The present narrative review aims to collate the literature regarding the current use of wearable gait measurement devices for falls-risk assessment in neurological and non-neurological populations. Thereby, this review seeks to determine the extent to which the aforementioned barriers inhibit clinical use. Background: Falls contribute a significant disease burden in most western countries, resulting in increased morbidity and mortality with substantial therapeutic costs. The recent development of gait analysis sensor technologies has enabled quantitative measurement of several gait features related to falls risk. However, three main barriers to implementation exist: accurately measuring gait-features associated with falls, differentiating between fallers and non-fallers using these gait features, and the accuracy of falls predictive algorithms developed using these gait measurements. Methods: Searches of Medline, PubMed, Embase and Scopus were screened to identify 46 articles relevant to the present study. Studies performing gait assessment using any wearable gait assessment device and analysing correlation with the occurrence of falls during a retrospective or prospective study period were included. Risk of Bias was assessed using the Centre for Evidence Based Medicine (CEBM) Criteria. Conclusions: Falls prediction algorithms based entirely, or in-part, on gait data have shown comparable or greater success of predicting falls than existing stratification scoring systems such as the 10-meter walk test or timed-up-and-go. However, data is lacking regarding their accuracy in neurological patient populations. Inertial measurement units (IMU) have displayed competency in obtaining and interpreting gait metrics relevant to falls risk. They have the potential to enhance the accuracy and efficiency of falls risk assessment in inpatient and outpatient setting.
Context: Despite increasing promising reports regarding composite titanium (Ti)/PolyEtherEtherKetone (PEEK) cages, further longer-term, quality research is required. Synthetic bone graft substitutes are another rapidly developing area of spinal surgical research. Aims: The purpose of this study is to evaluate the outcomes of an integral fixation composite Ti/PEEK cage for anterior cervical discectomy and fusion (ACDF) and compare a synthetic bone graft substitute (β-tricalcium phosphate; [βTCP]) with allograft processed using supercritical fluid technology. Methods and Design: Data from 195 consecutive patients were prospectively collected from a single centre. Indications were largely degenerative. Allograft and βTCP were used in a 3:1 randomization protocol. Patients were followed up for a minimum of 6 months and up to 48 months. Clinical outcomes included visual analogue scale and neck oswestry disability index. Radiographic outcomes included fusion rates, subsidence rates and implant complications. Results: Graft sub-cohorts were largely comparable and included 133 and 52 patients in the allograft and βTCP sub-cohorts, respectively. Clinical outcomes overall significantly improved (P < 0.001), with no significant inter-cohort differences. There were no implant-related complications. Overall fusion rate was 94.1% (175/186). The allograft cohort produced a significantly greater fusion rate of 97.7% (126/129) compared to 77.6% (38/49) for the βTCP cohort (P = 0.001). Conclusions: This study demonstrates the viability of an integral fixation composite Ti/PEEK ACDF device in effectively and safely improving patient outcomes and achieving fusion. Allograft is more effective in achieving fusion compared to βTCP, though both were similarly efficacious in improving clinical outcomes.
Faculty of Medicine, University of New South Wales, Sydney, Australia; NeuroSpine Surgery Research Group (NSURG), Sydney, Australia; Neurospine Clinic, Prince of Wales Private Hospital, Randwick, NSW 2031, Australia; Department of Neurosurgery, Prince of Wales Hospital, Randwick, NSW 2031, Australia Correspondence to: Ralph J. Mobbs. Suite 7, Level 7, Prince of Wales Private Hospital, Randwick, NSW 2031, Australia. Email: ralphmobbs@hotmail.com.
Clear cell meningioma is an uncommon variant of meningioma associated with high rates of local recurrence and metastasis. However, monitoring for local recurrence may be complicated by metal-related artefacts generated by spinal instrumentation. We present a patient with recurrent lumbar atypical clear cell meningioma, which had been resected multiple times throughout her adolescence. Due to extensive bone and ligament resection, posterior stabilization of the lumbar spine with pedicle screws was required. To ensure clear postoperative visualization of the spinal cord for local recurrence, a carbon fibre/polyetheretherketone (CF/PEEK) pedicle screw and rod construct was used. CF/PEEK has non-inferior biomechanical and biocompatible properties to titanium, with a clear advantage of radiolucency to assist in detecting the local recurrence early and facilitating accurate radiotherapy planning.