Introduction: Intramedullary nailing has become the gold standard in the treatment of femoral shaft fractures. This procedure involves the placement of distal interlocking bolts using the freehand technique. Accurate placement of distal interlocks can be a challenging task, especially in inexperienced hands. Misplacement of distal interlocking bolts can lead to iatrogenic fracture, instability of the bone-implant construct, or even malalignment of the extremity. Repeated drilling attempts increase radiation exposure and can cause additional bony and soft tissue trauma. We hypothesize that robot-guided placement of distal interlocks is more accurate, precise, and efficient than the freehand technique. Methods: A custom-designed drill guide was mounted onto the arm of an industrial robot. We developed a special device to secure a generic block (Synbone, Malans, Switzerland) into which an intramedullary nail could be inserted in a standardized way. A metric scale allowed later measurements of the drillings. Digital images were taken from each side of the block for analysis of the drilling trajectories. The fluoroscope was adjusted to obtain perfect circles of the distal interlocking holes. The number of images necessary to achieve this was recorded. The axis was recognized automatically by using the differences in contrast between the matrix of the generic bone and the implant (intramedullary nail). The drill trajectories were then computed. The robot with the mounted drill-guide automatically moved onto the calculated trajectory. The surgeon then executed the drilling. We performed 40 robot assisted drillings in generic blocks. Freehand drilling served as our control group. Results: Analysis of the digital images revealed a mean deviation of 0.94 mm and 2.7° off the ideal trajectory using robotic assistance. In 100% of the cases (n=40), the distal locking hole was hit. A mean of 8.8 images was acquired. After manual drilling, 92.5% of the distal interlocks were hit. A mean deviation of 3.66 mm and 10.36° was measured. A mean of 23.4 fluoroscopic images were needed. The differences between the two methods were statistically significant. Conclusion: Robot-guided drilling increases the accuracy and precision of distal interlocking while reducing irradiation. Considering economical and logistical aspects, this application should be integrated with robot-guided fracture reduction.
Introduction: The insertion site for an antegrade femoral intramedullary nail in the treatment of a femoral shaft fracture has traditionally been performed using a free-hand technique. An inappropriate starting point can result in suboptimal nail insertion leading to malreduction, or iatrogenic fracture. Furthermore, repeated attempts to establishthe optimal starting point cancause additional soft tissue trauma and radiation exposure. In the following study we compared a robot-guided technique with the standard free-hand technique for establishing the entry point of an antegrade femoral nail. We hypothesized that the robot-guided technique is more reliable and efficient.Methods: A custom-made drill-guide was mounted onto the arm of an industrial robot. Two orthogonal fluoroscopic images were acquired from the proximal femur of five cadaveric human specimens. Images were processed with a specialsoftwarein order to create an enhanced contour-recognition map from which the bone axes were automatically calculated. The drilling trajectory was computed along the extension of the bone-axis. The robot then moved the drill-guide on this trajectory toward the entry point. The drilling was then performed by the surgeon. In the control group, five cadaveric human femora were utilized to manually establish the starting pointusing the free-hand technique.Results: 100% of the intramedullary cavities were successfully accessed with both the robot-guided and the manual techniques. In the manual technique repositioning of the drill was necessary in three out of five cases. The mean number of acquired fluoroscopic images was significantly reduced from 11.6 (manual) to 4 (robot-guided).Conclusion: Robot-assisted drilling ofthe entry-point in antegrade femoral nailingis more reliable and requires fewer radiographic images than the free hand technique. Yet, based on economical and logistical considerations, its application will probably only be accepted when a concomitant application for fracture reduction is available.
Reduction in femoral shaft fractures may be difficult to achieve with minimal invasive techniques. Malalignment and high intraoperative radiation exposures often results. Our hypothesis is that robot assisted fracture reduction may improve the precision of reduction while reducing the amount of radiation exposure. We present a telemanipulator system for robot assisted reduction of femoral shaft fractures. The telemanipulated reduction is performed with a 2 dof input device with haptical feedback based on intraoperatively acquired 3D imaging data. We performed a test series to measure achievable reduction accuracies on artificially broken human femur bones without soft tissues. Furthermore, we performed first tests for the reduction on complete human legs in 3D. It could be shown, that telemanipulated reduction of such fractures in 3D is yielding very good accuracies in an intuitive and efficient way. Robot assisted fracture reduction can improve the reduction accuracy and reduce the X-ray irradiation exposure to the patient and the OR staff.