Purpose: Volumetric, high-resolution, quantitative mapping of brain tissue relaxation properties is hindered by long acquisition times and signal-to-noise (SNR) challenges. This study, for the first time, combines the time-efficient wave-CAIPI readouts into the 3D-quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) acquisition scheme, enabling full brain quantitative T1, T2 and proton density (PD) maps at 1.15 mm3 isotropic voxels in only 3 minutes. Methods: Wave-CAIPI readouts were embedded in the standard 3D-QALAS encoding scheme, enabling full brain quantitative parameter maps (T1, T2, and PD) at acceleration factors of R=3x2 with minimum SNR loss due to g-factor penalties. The quantitative parameter maps were estimated using a dictionary-based mapping algorithm incorporating inversion efficiency and B1 field inhomogeneity. The quantitative maps using the accelerated protocol were quantitatively compared against those obtained from conventional 3D-QALAS sequence using GRAPPA acceleration of R=2 in the ISMRM NIST phantom, and ten healthy volunteers. Results: When tested in both the ISMRM/NIST phantom and ten healthy volunteers, the quantitative maps using the accelerated protocol showed excellent agreement against those obtained from conventional 3D-QALAS at RGRAPPA=2. Conclusion: 3D-QALAS enhanced with wave-CAIPI readouts enables time-efficient, full brain quantitative T1, T2, and PD mapping at 1.15 mm3 in 3 minutes at R=3x2 acceleration. When tested on the NIST phantom and ten healthy volunteers, the quantitative maps obtained from the accelerated wave-CAIPI 3D-QALAS protocol showed very similar values to those obtained from the standard 3D-QALAS (R=2) protocol, alluding to the robustness and reliability of the proposed methods.
We recently presented a method for the quantitative measurement of the arterial input function which allows for determination of absolute cerebral blood flow (CBF) values without adjustable parameters. The aim of the present work is to estimate absolute CBF values by using this new technique and to compare it with the gold standard for cerebral perfusion, H215O positron emission tomography.
Imaging of cerebral perfusion by tracking the first passage of an exogenous paramagnetic contrast agent (termed dynamic susceptibility contrast, MRI) has been used in the clinical practice for about a decade. However, the primary goal of dynamic susceptibility contrast MRI to directly quantify the local cerebral blood flow remains elusive. The major challenge of dynamic susceptibility contrast MRI is to measure the contrast inflow to the brain, i.e., the arterial input function. The measurement is complicated by the limited dynamic range of MRI pulse sequences that are optimized for a good contrast in brain tissue but are suboptimal for a much higher tracer concentration in arterial blood. In this work, we suggest a novel method for direct arterial input function quantification. The arterial input function is measured in the carotid arteries with a dedicated plug‐in to the conventional pulse sequence to enable resolution of T 2 on the order of a millisecond. The new technique is compatible with the clinical measurement protocols. Applied to the pig model ( N = 13), the method demonstrates robustness of the arterial input function measurement. The cardiac output and cerebral blood volume, obtained without adjustable parameters, agree well with positron emission tomography measurements and values found in the literature. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.
PurposeWe recently presented a method for the quantitative measurement of the arterial input function which allows for determination of absolute cerebral blood flow (CBF) values without adjustable parameters. The aim of the present work is to estimate absolute CBF values by using this new technique and to compare it with the gold standard for cerebral perfusion, (H2O)-O-15 positron emission tomography.MethodsPigs (13) were comparatively investigated by each method performing multiple measurement runs. The reproducibility of both methods was assessed by a voxel-wise correlation of repeated measurements. An intersubject evaluation was performed on median whole-brain CBF estimates.ResultsThe mean CBF (MRI) was 204mL/100g/min for gray matter, the mean CBF (positron emission tomography) was 24 +/- 6mL/100g/min for gray and white matter. The reproducibility for MRI correlated with r=0.85 and P<0.0001, for positron emission tomography with r=0.76 and P<0.0001. The correlation for the median whole-brain CBF in MRI and positron emission tomography was r=0.60 and P=0.04.ConclusionsThe proposed method allows for determination of quantitative CBF without normalization factors. The relatively low estimates of absolute CBF most likely results from the higher age of the pigs as compared to other studies. The intermediate correlation between both methods is caused by physiological intraindividual fluctuations of the CBF and by a limited reproducibility of both methods. Magn Reson Med 72:1723-1734, 2014. (c) 2013 Wiley Periodicals, Inc.
Elias Kellner, Irina Mader, Daniel Nico Splitthoff, Marco Reisert, Katharina Förster, Thao Nguyen-Thanh, Peter Gall, and Valerij G. Kiselev Department of Radiology, Medical Physics, University Medical Center Freiburg, D-79106 Freiburg, Germany, Section of Neuroradiology, Neurocenter of the Freiburg University Hospital, D-79106 Freiburg, Germany, Department of Cardiovascular Surgery, Albert-Ludwigs-University Freiburg, D-79106 Freiburg, Germany
The purpose of this work is to demonstrate the functionality and performance of a PSF-based geometric distortion correction for high-field functional animal EPI. The EPI method was extended to measure the PSF and a postprocessing chain was implemented in Matlab for offline distortion correction. The correction procedure was applied to phantom and in vivo imaging of mice and rats at 9.4T using different SE-EPI and DWI-EPI protocols. Results show the significant improvement in image quality for single- and multishot EPI. Using a reduced FOV in the PSF encoding direction clearly reduced the acquisition time for PSF data by an acceleration factor of 2 or 4, without affecting the correction quality.