A surface plasmon resonance (SPR) immunobiosensor assay was developed and validated to detect microcystin toxins in Spirulina and Aphanizomenon flos-aquae blue-green algae (BGA) food supplements. A competitive inhibition SPR-biosensor was developed using a monoclonal antibody to detect microcystin (MC) toxins. Powdered BGA samples were extracted with an aqueous methanolic solution, centrifuged and diluted in HBS-EP buffer prior to analysis. The assay was validated in accordance with the performance criteria outlined in EU legislation 2002/657/EC. The limit of detection (LOD) of the assay was calculated from the analysis of 20 known negative BGA samples to be 0.561 mg kg−1. The detection capability (CCβ) of the assay was determined to be ≤0.85 mg kg−1 for MC-LR. The biosensor assay was successfully applied to detect MC-LR toxins in BGA samples purchased on the Irish retail market. MC-LR was detected in samples at levels ranging from <0.5 to 2.21 mg kg−1. The biosensor results were in good agreement with an established LC–MS/MS assay. The assay is advantageous because it employs a simple clean-up procedure compared to chemical assays and allows automated unattended analysis of samples unlike ELISA.
A 1.0 x 0.4 cm silica based monolithic anion exchanger has been produced and evaluated for use within a miniature gradient suppressed ion chromatography system based upon low-pressure micro-scale peristaltic pumps.
Short permanently coated reversed-phase silica based monolithic columns have been investigated for the rapid separation of inorganic anions and cations. One 2.5 x 0.46 cm column was permanently coated with didodecyldimethylammonium (DDAB), for anion analysis; and a second 5.0 x 0.46 cm column was coated with dioctylsulphosuccinnate (DOSS), for cation analysis. The use of a single combined eluent of 2.5 mM phthalate/1.5 mM ethylenediamine, at flow rates of between 4.0 and 8.0 mL/min, resulted in the rapid separation of 8 anions (in under 100 s) and 5 cations (in under 100 s) on the above columns when used individually, with detection limits for common anions ranging from approximately 0.25 to 5 mg/L, and between 2.5 and 50 mg/L for alkaline earth metals, by direct and indirect conductivity detection, respectively. However, with both columns subsequently connected in parallel, with the eluent delivered using a flow splitter from a single isocratic pump, the simultaneous analysis of anions and cations was also possible, based on a single conductivity detector. The potential of this system for the rapid, complete screening of water samples for multiple common anions and cations is shown.