Paediatric imaging protocols should be carefully optimised to maintain the desired image quality while minimising the delivered patient dose. A paediatric chest phantom was designed, constructed and evaluated to optimise chest CT examinations for infants. The phantom was designed to enable dosimetry and image quality measurements within the anthropomorphic structure. It was constructed using tissue equivalent materials to mimic thoracic structures of infants, aged 0–6 months. The phantom materials were validated across a range of diagnostic tube voltages with resulting CT numbers found equivalent to paediatric tissues observed via a survey of clinical paediatric chest studies. The phantom has been successfully used to measure radiation dose and evaluate various image quality parameters for paediatric specific protocols.
A 3D-printed metal solid target using additive manufacturing process is a cost-effective production solution to complex and intricate target design. The initial proof-of-concept prototype solid target holder was 3D-printed in cast alloy, Al–7Si–0.6Mg (A357). However, given the relatively low thermal conductivity for A357 (κmax, 160 W/m·K), replication of the solid target holder in sterling silver (SS925) with higher thermal conductivity (κmax, 361 W/m·K) was investigated. The SS925 target holder enhances the cooling efficiency of the target design, thus achieving higher target current during irradiation. A validation production of 64Cu using the 3D-printed SS925 target holder indicated no loss of enriched 64Ni from proton bombardment above 80 µA, at 11.5 MeV.
Well type chambers are used for radioactive source calibrations in brachytherapy, but do not provide radiation shielding. Routine constancy checks on a well chamber are required between periodic secondary standard laboratory calibrations to ensure consistent device performance, and ultimately to ensure accurate patient dose delivery. In this work, a method is described to provide suitable shielding for a Cs-137 rod-type point source to enable use for constancy checks. A novel plunger-type shielded housing was designed and constructed for the Cs-137 source that when combined with a suitably shielded well-chamber container minimised user exposure during constancy checks. The designed shielding proved effective, and a constancy test routine was established and used for the past 16 months. The well chamber showed consistent performance (0.12 ± 0.18 % from the baseline) and no increased exposure was reported on users’ radiation badges.
We measured the excitation functions of (nat)Zn (p,x) reactions up to 17.6MeV, using the stacked-foils activation technique. High-purity natural zinc (and copper) foils were irradiated with proton beams generated by an 18MeV isochronous cyclotron. Activated foils were measured using high-purity Ge gamma spectroscopy to quantify the radionuclides (61)Cu, (66)Ga, (67)Ga, and (65)Zn produced from the reactions. Thick-target integral yields were also deduced from the measured excitation functions of the produced radioisotopes. These results were compared with the published literature and were found to be in good agreement with most reports, particularly those most recently compiled.