Abstract In this paper we report a direct experimental investigation of optical frequency chirping effects induced by ultrashort electron bunches in a high-gain energy-recovery-linac (ERL) free-electron laser (FEL) cavity. Our measurement and analysis show clear evolution of the optical pulse chirp verses the electron bunch energy chirp. Further study also provides important evidence that under certain conditions much shorter FEL pulses can be obtained through properly chirping electron bunches and optical pulse compression. Although studies of chirp measurements on Self-Amplified-Spontaneous-Emission (SASE) FELs have been reported, this paper provides the first observations of the unique temporal and spectral characteristics of ultrashort optical pulses from a highgain ERL FEL. This is made possible by the stable operation and unique capability of the Jefferson Lab machine to change the electron bunch energy chirp with no curvature.
The cavity optics within high power free-electron lasers based on energy-recovering accelerators are subjected to extreme conditions associated with illumination from a broad spectrum of radiation, which under some conditions could be at high irradiances. In our designs, we relied on literature values for CW or quasi-cw lasers like copper-vapor lasers to set an operational limit of 100 kW/cm2. Recently we conducted a test to explore the damage threshold for our cavity optics. When operating at 1.6 microns, we found the optics damaged at irradiances substantially above 100 kW/cm2. Details of the test and a discussion of the damage morphology will be presented.
The cavity optics within high power free-electron lasers based on energy-recovering accelerators are subjected to extreme conditions associated with illumination from a broad spectrum of radiation, often at high irradiances. This is especially true for the output coupler, where absorption of radiation by both the mirror substrate and coating places significant design restrictions to properly manage heat load and prevent mirror distortion. Besides the fundamental lasing wavelength, the mirrors are irradiated with light at harmonics of the fundamental, THz radiation generated by the bending magnets downstream of the wiggler, and x-rays produced when the electron beam strikes accelerator diagnostic components (e.g., wire scanners and view screens) or from inadvertent beam loss. The optics must reside within high vacuum at similar to 10(-8) Toff and this requirement introduces its own set of complications. This talk discusses the performance of numerous high reflector and output coupler optics assemblies and provides a detailed list of lessons learned gleaned from years of experience operating the Upgrade IR FEL, a 10 kW-class, sub-ps laser with output wavelength from I to 6 microns.
Notional designs for energy-recovering linac ("ERL") driven high average power free electron lasers ("FEL"s) often invoke amplifier-based architectures. To date, however, amplifier FELs have been limited in average power output to values several orders of magnitude lower than those demonstrated in optical-resonator based systems; this is due at least in part to the limited electron beam powers available from their driver accelerators. In order to directly contrast the performance available from amplifiers to that provided by high-power cavity-based resonators, we have developed a scheme to test an amplifier FEL in the JLab SRF ERL driver. We describe an accelerator system design that can seamlessly and noninvasively integrate a 10 m wiggler into the existing system and which provides, at least in principle, performance that would support high-efficiency lasing in an amplifier configuration. Details of the design and an accelerator performance analysis will be presented.
We have been operating a high-power energy-recovery linac (ERL) at Jefferson Lab for several years. In the process we have learned quite a bit about both technical and physics limitations in high power ERLs. Several groups are now considering new ERLs that greatly in- crease either the energy, the current or both. We will present some of our findings on what to consider when designing, building, and operating a high power ERL. Our remarks for this paper are limited to lattice design and setup, magnets, vacuum chamber design, diagnostics, and beam stability.