Mitigation of a bottleneck significantly improved (R)-3HB productivity, and metabolic flux analysis delineated dramatic metabolic flux changes in cyanobacteriumSynechocystis.
We present a new approach for three-dimensional (3D) live single-cell imaging with isotropic sub-micron spatial resolution using fluorescence computed tomography (fCT). A thin, highly inclined and laminated optical (HILO) sheet of light is used for fluorescence excitation in live single cells that are rotated around an axis perpendicular to the optical axis. During a full rotation, 400-500 two-dimensional (2D) projection images of the cell are acquired from multiple viewing perspectives by rapidly scanning the HILO light sheet along the optical axis. We report technical characteristics of the HILO approach and the results of a quantitative comparison with conventional epi fCT, demonstrating that HILO fCT offers significantly (about 17 times) reduced photobleaching and a two-fold improvement in 3D imaging contrast. We discuss potential application areas of the method for cell structure studies in live single cells with isotropic 3D spatial resolution.
Functional and genomic heterogeneity of individual cells are central players in a broad spectrum of normal and disease states. Our knowledge about the role of cellular heterogeneity in tissue and organism function remains limited due to analytical challenges one encounters when performing single cell studies in the context of cell-cell interactions. Information based on bulk samples represents ensemble averages over populations of cells, while data generated from isolated single cells do not account for intercellular interactions. We describe a new technology and demonstrate two important advantages over existing technologies: first, it enables multiparameter energy metabolism profiling of small cell populations (<100 cells)-a sample size that is at least an order of magnitude smaller than other, commercially available technologies; second, it can perform simultaneous real-time measurements of oxygen consumption rate (OCR), extracellular acidification rate (ECAR), and mitochondrial membrane potential (MMP)-a capability not offered by any other commercially available technology. Our results revealed substantial diversity in response kinetics of the three analytes in dysplastic human epithelial esophageal cells and suggest the existence of varying cellular energy metabolism profiles and their kinetics among small populations of cells. The technology represents a powerful analytical tool for multiparameter studies of cellular function.
Functional and molecular cell-to-cell variability is pivotal at the cellular, tissue and whole-organism levels. Yet, the ultimate goal of directly correlating the function of the individual cell with its biomolecular profile remains elusive. We present a platform for integrated analysis of functional and transcriptional phenotypes in the same single cells. We investigated changes in the cellular respiration and gene expression diversity resulting from adaptation to repeated episodes of acute hypoxia in a premalignant progression model. We find differential, progression stage-specific alterations in phenotypic heterogeneity and identify cells with aberrant phenotypes. To our knowledge, this study is the first demonstration of an integrated approach to elucidate how heterogeneity at the transcriptional level manifests in the physiologic profile of individual cells in the context of disease progression.
This work describes an enhancement to the loop-mediated isothermal amplification (LAMP) reaction which results in improved performance. Enhancement is achieved by adding a new set of primers to conventional LAMP reactions. These primers are termed "swarm primers" based on their relatively high concentration and their ability to create new amplicons despite the theoretical lack of single-stranded annealing sites. The primers target a region upstream of the FIP/BIP primer recognition sequences on opposite strands, substantially overlapping F1/B1 sites. Thus, despite the addition of a new primer set to an already complex assay, no significant increase in assay complexity is incurred. Swarm priming is presented for three DNA templates: Lambda phage, Synechocystis sp. PCC 6803 rbcL gene, and human HFE. The results of adding swarm primers to conventional LAMP reactions include increased amplification speed, increased indicator contrast, and increased reaction products. For at least one template, minor improvements in assay repeatability are also shown. In addition, swarm priming is shown to be effective at increasing the reaction speed for RNA amplification via RT-LAMP. Collectively, these results suggest that the addition of swarm primers will likely benefit most if not all existing LAMP assays based on state-of-the-art, six-primer reactions.
A new two-layer sensor film was constructed for sensing glucose based on glucose oxidase and oxygen sensing material. The first layer of film containing the oxygen sensor and intra-reference material was polymerized, then the second layer of glucose oxidase and glutaraldehyde was formed on the oxygen sensor layer. The two-layer sensor film has a resolution up to 0.05mM and a detection range from 0 to 5mM to glucose. The effects of pH and temperature on the sensing performance were systematically investigated. The selective detection of glucose among other monosaccharides, such as fructose, mannose and galactose indicated that the sensing film has excellent selectivity. The prepared sensor was successfully applied for glucose sample detection of glucose concentration in artificial tears.
We report on a method for rotating single mammalian cells about an axis perpendicular to the optical system axis through the imaging plane using dynamic holographic optical tweezers (HOTs). Two optical traps are created on the opposite edges of a mammalian cell and are continuously transitioned through the imaging plane along the circumference of the cell in opposite directions, thus providing the torque to rotate the cell in a controlled fashion. The method enables a complete 360° rotation of live single mammalian cells with spherical or near-to spherical shape in 3D space, and represents a useful tool suitable for the single cell analysis field, including tomographic imaging.
Quantitative three-dimensional (3D) computed tomography (CT) imaging of living single cells enables orientation-independent morphometric analysis of the intricacies of cellular physiology. Since its invention, x-ray CT has become indispensable in the clinic for diagnostic and prognostic purposes due to its quantitative absorption-based imaging in true 3D that allows objects of interest to be viewed and measured from any orientation. However, x-ray CT has not been useful at the level of single cells because there is insufficient contrast to form an image. Recently, optical CT has been developed successfully for fixed cells, but this technology called Cell-CT is incompatible with live-cell imaging due to the use of stains, such as hematoxylin, that are not compatible with cell viability. We present a novel development of optical CT for quantitative, multispectral functional 4D (three spatial + one spectral dimension) imaging of living single cells. The method applied to immune system cells offers truly isotropic 3D spatial resolution and enables time-resolved imaging studies of cells suspended in aqueous medium. Using live-cell optical CT, we found a heterogeneous response to mitochondrial fission inhibition in mouse macrophages and differential basal remodeling of small (0.1 to 1 fl) and large (1 to 20 fl) nuclear and mitochondrial structures on a 20- to 30-s time scale in human myelogenous leukemia cells. Because of its robust 3D measurement capabilities, live-cell optical CT represents a powerful new tool in the biomedical research field.
Driven by an increasing number of studies demonstrating its relevance to a broad variety of disease states, the bioenergy production phenotype has been widely characterized at the bulk sample level. Its cell-to-cell variability, a key player associated with cancer cell survival and recurrence, however, remains poorly understood due to ensemble averaging of the current approaches. We present a technology platform for performing oxygen consumption and extracellular acidification measurements of several hundreds to 1,000 individual cells per assay, while offering simultaneous analysis of cellular communication effects on the energy production phenotype. The platform comprises two major components: a tandem optical sensor for combined oxygen and pH detection, and a microwell device for isolation and analysis of single and few cells in hermetically sealed sub-nanoliter chambers. Our approach revealed subpopulations of cells with aberrant energy production profiles and enables determination of cellular response variability to electron transfer chain inhibitors and ion uncouplers.
Intercellular interactions play a central role at the tissue and whole organism level modulating key cellular functions in normal and disease states. Studies of cell-cell communications are challenging due to ensemble averaging effects brought about by intrinsic heterogeneity in cellular function which requires such studies to be conducted with small populations of cells. Most of the current methods for producing and studying such small cell populations are complex to implement and require skilled personnel limiting their widespread utility in biomedical research labs. We present a simple and rapid method to produce small populations with varying size of epithelial cells (10-50 cells/population) with high-throughput (~ 1 population/second) on flat surfaces via patterning of extracellular matrix (ECM) proteins and random seeding of cells. We demonstrate that despite inherent limitations of non-contact, drop-on-demand piezoelectric inkjet printing for protein patterning, varying mixtures of ECM proteins can be deposited with high reproducibility and level of control on glass substrates using a set of dynamically adjustable optimized deposition parameters. We demonstrate high consistency for the number of cells per population (~1 cell standard error of mean), the population's size (~0.2 coefficient of variation) and shape, as well as accurate spatial placement of and distance between colonies of a panel of metaplastic and dysplastic esophageal epithelial cells with differing adhesion and motility characteristics. The number of cells per colony, colony size and shape can be varied by dynamically varying the amount of ECM proteins deposited per spatial location and the number of spatial locations on the substrate. The method is applicable to a broad range of biological and biomedical studies including cell-cell communications, cellular microenvironment, migration, and stimulus response.
Precise spatial positioning and isolation of mammalian cells is a critical component of many single cell experimental methods and biological engineering applications. Although a variety of cell patterning methods have been demonstrated, many of these methods subject cells to high stress environments, discriminate against certain phenotypes, or are a challenge to implement. Here, we demonstrate a rapid, simple, indiscriminate, and minimally perturbing cell patterning method using a laser fabricated polymer stencil. The stencil fabrication process requires no stencil-substrate alignment, and is readily adaptable to various substrate geometries and experiments.
Abstract Quantitative 3D imaging of live single tumor cells enables direct insights into the intricacies of cellular machinery while offering new ways of assessing intercellular variability. Since its invention, X-ray computed tomography has been indispensable in the clinic for cancer diagnostic and prognostic purposes due to its quantitative manner of imaging owing to the isotropic 3D spatial resolution. Although its principles have recently begun to be implemented in the optical spectral range for single cell imaging, the applications have mainly been directed towards imaging fixed cells in absorption mode for studying an important hallmark of cancer - nuclear architecture. We present an approach that utilizes the concept of computed tomography for quantitative functional 3D imaging of live single cells. The method offers truly isotropic 3D spatial resolution and enables imaging of natural suspension cells, such as non-solid tumor or immune system cells, as opposed to cells attached to substrates, as is common to the majority of other imaging approaches. We report on technical characteristics of the method as well as experimental findings of a nuclear and mitochondrial dynamics study in human myelogenous leukemia and mouse macrophage cells as a validation. The absolute quantification capability of the method makes it a powerful tool in the field of oncology by enabling direct studies of cellular and nuclear architecture dynamics in the context of tumorigenesis and progression. Citation Format: Laimonas Kelbauskas, Rishabh M. Shetty, Bin Cao, Kuo-Chen Wang, Dean Smith, Hong Wang, Shih-Hui Chao, Brian Ashcroft, Margaret Kritzer, Honor Glenn, Erik Niemela, Roger H. Johnson, John Eriksson, Deirdre R. Meldrum. Computed tomography for quantitative imaging of live cancer cells with isotropic 3D spatial resolution. [abstract]. In: Proceedings of the AACR Special Conference on Engineering and Physical Sciences in Oncology; 2016 Jun 25-28; Boston, MA. Philadelphia (PA): AACR; Cancer Res 2017;77(2 Suppl):Abstract nr B15.
This paper presents three different microfabrication technologies for manufacturing out-of-plane, flat-bottomed, undercut trapezoidal structures for generating a fluidic microscale vortex (microvortex). The first method is based on anisotropic silicon etching and a 'sandwich' UV polymer casting assembly; the second method uses a backside diffuser photolithography technique; and the third method features a tilted backside photolithography technique. We discuss the advantages, limitations, and utility of each technique. We further demonstrate that the microvortex generated in the resultant undercut trapezoidal structures can be used to rotate biological microparticles, e.g. single, live cells for multiperspective, high resolution 3D imaging using computed tomography, and angularly resolved confocal imaging.
The histone deacetylase (HDAC) inhibitor vorinostat has received significant attention in recent years as an 'epigenetic' drug used to treat solid tumors. However, its mechanisms of action are not entirely understood, particularly with regard to its interaction with the aberrations in 3D nuclear structure that accompany neoplastic progression. We investigated the impact of vorinostat on human esophageal epithelial cell lines derived from normal, metaplastic (pre-cancerous), and malignant tissue. Using a combination of novel optical computed tomography (CT)-based quantitative 3D absorption microscopy and conventional confocal fluorescence microscopy, we show that subjecting malignant cells to vorinostat preferentially alters their 3D nuclear architecture relative to non-cancerous cells. Optical CT (cell CT) imaging of fixed single cells showed that drug-treated cancer cells exhibit significant alterations in nuclear morphometry. Confocal microscopy revealed that vorinostat caused changes in the distribution of H3K9ac-marked euchromatin and H3K9me3-marked constitutive heterochromatin. Additionally, 3D immuno-FISH showed that drug-induced expression of the DNA repair gene MGMT was accompanied by spatial relocation toward the center of the nucleus in the nuclei of metaplastic but not in non-neoplastic cells. Our data suggest that vorinostat's differential modulation of 3D nuclear architecture in normal and abnormal cells could play a functional role in its anti-cancer action.
Migration is a fundamental cellular behavior that plays an indispensable role in development and homeostasis, but can also contribute to pathology such as cancer metastasis. Due to its relevance to many aspects of human health, the ability to accurately measure cell migration is of broad interest, and numerous approaches have been developed. One of the most commonly employed approaches, because of its simplicity and throughput, is the exclusion zone assay in which cells are allowed to migrate into an initially cell-free region. A major drawback of this assay is that it relies on simply counting cells in the exclusion zone and therefore cannot distinguish the effects of proliferation from migration. We report here a simple modification to the exclusion zone migration assay that exclusively measures cell migration and is not affected by proliferation. This approach makes use of a lineage-tracing vital stain that is retained through cell generations and effectively reads out migration relative to the original, parental cell population. This modification is simple, robust, non-perturbing, and inexpensive. We validate the method in a panel of cell lines under conditions that inhibit or promote migration and demonstrate its use in normal and cancer cell lines as well as primary cells.
An ideal fluorescent dye for staining cell organelles should have multiple properties including specificity, stability, biocompatibility, and a large Stokes shift. Tunable photophysical properties enable 1,8‐naphthalimide to serve as an excellent fluorophore in biomedical applications. Many naphthalimide derivatives have been developed into drugs, sensors, and other dyes. In this study, a series of 1,8‐naphthalimide derivatives targeting live cell mitochondria were synthesized. Among these probes, Mt‐4 was characterized as the best one, with highly specific mitochondrial localization, low cytotoxicity, and a large Stokes shift. More importantly, Mt‐4 stood out as a potential mitochondrial dye for living‐cell experiments involving induced mitochondrial stress arising from the treatments because Mt‐4 shows enhanced fluorescence in mitochondrial stress situations.
La presente invention concerne une structure d'etancheite multicouche pour etancheifier un ensemble de micropuits defini dans ou sur un substrat qui comprend au moins une couche flexible avant, une couche flexible arriere, et une couche de flexion agencee entre l'au moins une couche flexible avant et la couche flexible arriere, dans laquelle l'au moins une couche flexible avant est plus proche que la couche flexible arriere des micropuits de l'ensemble de micropuits. Une ou plusieurs couches flexibles avant peuvent etre optiquement reflechissantes et/ou peuvent constituer une couche de capteur. La couche flexible arriere peut comprendre un adhesif ou differents types de caoutchouc, et la couche de flexion peut comprendre un materiau polymere ou un metal. Une structure d'etancheite multicouche peut etre separee d'un ensemble de micropuits par pelage. Une structure d'etancheite multicouche permet la rupture locale de l'etancheite a l'emplacement ou des contaminants particulaires sont presents sans compromettre la performance d'etancheite d'un ensemble de micropuits entier, et sans necessiter une force d'etancheite elevee.
Extracellular pH has a strong effect on cell metabolism and growth. Precisely detecting extracellular pH with high throughput is critical for cell metabolism research and fermentation applications. In this research, a series of ratiometric fluorescent pH sensitive polymers are developed and the ps-pH-neutral is characterized as the best one for exculsive detection of extracellular pH. Poly(N-(2-hydroxypropyl)methacrylamide) (PHPMA) is used as the host polymer to increase the water solubility of the pH sensitive polymer without introducing cell toxicity. The fluorescent emission spectra from the polymeric sensor under excitation at the isosbestic point 455 nm possess two fluorescence peaks at 475 nm and 505 nm, which have different responding trends to pH. This enables the polymer to detect pH using fluorescent maxima at 475 nm and 505 nm (I475nm /I505nm ) ratiometrically. The cell impermeability ensures the sensor can solely detect the environmental pH. The sensor is tested to detect the extracellular pH of bacteria or eukaryotic cells in high throughput assays using a microplate reader. Results showed that the pH sensor can be used for high throughput detection of extracellular pH with high repeatability and low photobleaching effect.