BACKGROUND:Parenterally administered ascorbic acid modulates sepsis-induced inflammation and coagulation in experimental animal models. The objective of this randomized, double-blind, placebo-controlled, phase I trial was to determine the safety of intravenously infused ascorbic acid in patients with severe sepsis.METHODS:Twenty-four patients with severe sepsis in the medical intensive care unit were randomized 1:1:1 to receive intravenous infusions every six hours for four days of ascorbic acid: Lo-AscA (50 mg/kg/24 h, n = 8), or Hi-AscA (200 mg/kg/24 h, n = 8), or Placebo (5% dextrose/water, n = 8). The primary end points were ascorbic acid safety and tolerability, assessed as treatment-related adverse-event frequency and severity. Patients were monitored for worsened arterial hypotension, tachycardia, hypernatremia, and nausea or vomiting. In addition Sequential Organ Failure Assessment (SOFA) scores and plasma levels of ascorbic acid, C-reactive protein, procalcitonin, and thrombomodulin were monitored.RESULTS:Mean plasma ascorbic acid levels at entry for the entire cohort were 17.9 ± 2.4 μM (normal range 50-70 μM). Ascorbic acid infusion rapidly and significantly increased plasma ascorbic acid levels. No adverse safety events were observed in ascorbic acid-infused patients. Patients receiving ascorbic acid exhibited prompt reductions in SOFA scores while placebo patients exhibited no such reduction. Ascorbic acid significantly reduced the proinflammatory biomarkers C-reactive protein and procalcitonin. Unlike placebo patients, thrombomodulin in ascorbic acid infused patients exhibited no significant rise, suggesting attenuation of vascular endothelial injury.CONCLUSIONS:Intravenous ascorbic acid infusion was safe and well tolerated in this study and may positively impact the extent of multiple organ failure and biomarkers of inflammation and endothelial injury.TRIAL REGISTRATION:ClinicalTrials.gov identifier NCT01434121.
Moist smokeless tobacco use is associated with various types of oral injury, including leukoplakia and dipper's pouch, although the mechanism by which the injury is caused still remains unclear. One possible mechanism is that moist smokeless tobacco affects the inflammatory response. For example, a study by Johnson et al. demonstrated a reduction in the volume density of macrophages and increased inflammation and redness at the smokeless tobacco placement site when compared to non-placement site. The current study investigated the direct effect of reference moist smokeless tobacco extract (STE) exposure on the viability of MM6 monocyte/macrophage cell line. The exposure of MM6 cells to various concentrations of STE, led to a significant and dose-related decrease in cell viability. Furthermore, STE exposure resulted in an increase in Annexin V/PI positive cells, an increase in TUNEL-positive cells, and cleaved PARP staining all of which were inhibited by pre-incubation with a pan-caspase inhibitor, suggesting that the observed STE toxicity was due to the induction of apoptosis. Next, the role of various moist smokeless tobacco-derived components in STE-induced apoptosis of MM6 cells was investigated. Our findings suggest that STE-induced osmotic stress, but not exposure to nicotine, plays an important role in STE-induced apoptosis of MM6 cells. Together, these data show for the first time that STE exposure leads to the induction of apoptosis in human monocyte/macrophage cells, which appears to be induced in part, by reference STE-mediated osmotic stress.
STUDY OBJECTIVES:To assess the influence of in vitro and in vivo hemodialysis with a new high-flux dialyzer on the clearance of cefazolin and cefepime; to assess the correlation of in vivo dialytic clearance of these antibiotics with blood flow rate; and to assess the correlation between in vitro and in vivo dialytic clearances of these antibiotics.DESIGN:Prospective, open-label, dialysis clearance study.SETTING:A tertiary-care, university health science center.PATIENTS:Five adults who received high-flux hemodialysis 3 times/week. Intervention. For the in vivo experiment, patients received a single intravenous infusion of cefazolin 1 g and cefepime 1 g before dialysis and then underwent a modified hemodialysis session. For the in vitro experiment, a buffered simulated plasma water (SPW) solution containing cefazolin and cefepime was used. Hemodialysis for both experiments was performed with use of a new high-flux polysulfone dialyzer.MEASUREMENTS AND MAIN RESULTS:Cefazolin and cefepime dialytic clearances were determined at blood and/or SPW flow rates of 100, 200, 300, and 400 ml/minute after a 15-minute equilibration period. The degree of correlation of in vitro and in vivo clearances with blood flow rate was determined. Cefepime dialytic clearance increased proportionally with blood flow rate (p<0.01), reaching a maximum mean +/- SD value of 178.9 +/- 24.3 ml/minute at a blood flow rate of 400 ml/minute. Cefazolin dialytic clearance ranged from a mean +/- SD of 42.3 +/- 7.7 to 52.7 +/- 16 ml/minute; no significant correlation was noted between blood flow rate and dialytic clearance. In vitro cefazolin and cefepime dialytic clearances increased proportionally with SPW flow rate (p<0.05). After adjusting the in vitro cefazolin and cefepime dialytic clearances based on their degrees of protein binding, the correlation between the in vitro and in vivo cefepime dialytic clearances was significant (r(2)=0.91, p=0.04), but no significant correlation was noted between the in vitro and in vivo cefazolin clearances (r(2)=0.61, p=0.22).CONCLUSION:The in vivo hemodialysis clearances of cefepime and cefazolin with the new high-flux polysulfone dialyzer used in this study are markedly higher than values reported with conventional dialyzers but similar to values observed with other high-flux hemodialyzers. The in vivo dialytic clearance of cefazolin was significantly lower than the in vitro values, most likely due to cefazolin's high degree of protein binding. These results highlight the limitation of directly applying in vitro data to clinical situations.
A simple high-performance liquid chromatographic (HPLC) method was developed for the simultaneous determination of cefepime and cefazolin in human plasma and dialysate. For component separation, the method utilized a C18 column with an aqueous mobile phase of dibasic potassium hydrogen phosphate (pH 7.0) and methanol gradient at a flow rate of 1 mL min−1. The method demonstrated linearity from 2.0 to 100.0 μg mL−1 (r > 0.999) with detection limit of 1 μg mL−1 for both cefepime and cefazolin. The method was utilized for evaluation of plasma and dialysate samples in a clinical study evaluating the dialyzer clearance of cefepime and cefazolin using high-flux hemodialysis with varying blood flow rates in chronic kidney failure patients undergoing hemodialysis and peritoneal dialysis treatment.
Acetyl salicylic acid (aspirin) is one of the most widely used drugs in the world. Various plasma concentrations of aspirin and its predominant metabolite, salicylic acid, are required for its antiarthritic (1.5-2.5 mM), anti-inflammatory (0.5-5.0 mM) or antiplatelet (0.18-0.36 mM) actions. A recent study demonstrated the inhibitory effects of both aspirin and salicylic acid on oxidative phosphorylation and ATP synthesis in isolated rat cardiac mitochondria in a dose-dependent manner (0-10 mM concentration range). In this context, the present study was conducted to determine the effects of salicylic acid on inosine efflux (a potential biomarker of acute cardiac ischaemia) as well as cardiac contractile function in the isolated mouse heart following 20 min of zero-flow global ischaemia. Inosine efflux was found at significantly higher concentrations in ischaemic hearts perfused with Krebs buffer fortified with 1.0 mM salicylic acid compared with those without salicylic acid (12575+/-3319 vs. 1437+/-348 ng ml(-1) min(-1), mean+/-SEM, n=6 per group, p<0.01). These results indicate that 1.0 mM salicylic acid potentiates 8.8-fold ATP nucleotide purine catabolism into its metabolites (e.g. inosine, hypoxanthine). Salicylic acid (0.1 or 1.0 mM) did not appreciably inhibit purine nucleoside phosphorylase (the enzyme converts inosine to hypoxanthine) suggesting the augmented inosine efflux was due to the salicylic acid effect on upstream elements of cellular respiration. Whereas post-ischaemic cardiac function was further depressed by 1.0 mM salicylic acid, perfusion with 0.1 mM salicylic acid led to a remarkable functional improvement despite moderately increased inosine efflux (2.7-fold). We conclude that inosine is a sensitive biomarker for detecting cardiac ischaemia and salicylic acid-induced effects on cellular respiration. However, the inosine efflux level appears to be a poor predictor of the individual post-ischaemic cardiac functional recovery in this ex vivo model.
A simple and sensitive high-performance liquid chromatography (HPLC) method utilizing ultraviolet (UV) detection was developed for the determination of inosine and hypoxanthine in human plasma. For component separation, a monolithic C(18) column at a flow rate of 1.0 mL/min with an aqueous mobile phase of trifluoroacetic acid (0.1% TFA in deionized water pH 2.2, v/v) and methanol gradient was used. The method employed a one-step sample preparation utilizing centrifugal filtration with high component recoveries (approximately 98%) from plasma, which eliminated the need of an internal standard. The method demonstrated excellent linearity (0.25-5 microg/mL, R>0.9990) for both inosine and hypoxanthine with detection limits of 100 ng/mL. This simple and cost effective method was utilized to evaluate potential endogenous plasma biomarker(s), which may aid hospital emergency personnel in the early detection of acute cardiac ischemia in patients presenting with non-traumatic chest pain.
Each year in the USA approximately 7-8 million patients with non-traumatic chest pain come to hospital emergency rooms. It is estimated that approximately 2-5% of these patients are experiencing cardiac ischaemia, but due to the shortcomings of the available testing methods they are incorrectly diagnosed and discharged without appropriate therapy having been provided. Preliminary data with a globally ischaemic mouse heart model has demonstrated that endogenous inosine might be a potential biomarker of initial cardiac ischaemia before cardiac tissue necrosis. A high-performance liquid chromatographic diode array detection (HPLC-DAD) method was utilized for the detection and quantification of inosine in Krebs-Henseleit (Krebs) buffer solution perfusing from surgically removed and isolated mouse hearts undergoing global cardiac ischaemia. A C-18 column at a flow rate of 0.6 ml min(-1) with an aqueous mobile phase of trifluoroacetic acid (0.05% trifluoroacetic acid in deionized water, pH 2.2, v/v) and methanol gradient was used for component separation. The assay detection limit for inosine in Krebs buffer solution was 500 ng ml(-1) using a 100-ml neat injection. The HPLC results were used to determine total cardiac effluxed inosine into the Krebs effluent for each mouse during oxidative stress and compared with the per cent cardiac ventricular functional recovery rate to determine if a relationship exists amongst this cardiovascular parameter during periods of cardiac oxidative stress.
A simple high-performance liquid chromatographic (HPLC) method was developed for the simultaneous determination of iohexol, iothalamate, p-aminohippuric acid (PAH) and n-acetyl-p-aminohippuric acid (n-acetyl-PAH) in human plasma and urine. A C18 column at a flow rate of 1 ml/min with an aqueous mobile phase of trifluoroacetic acid (0.1% TFA in deionized water (pH 2.2), v/v) and methanol gradient was used for component separation. The plasma and urine assay demonstrated linearity from 10 to 50 μg/ml for iohexol and iothalamate, 5 to 40 μg/ml for PAH and 2.5 to 40 μg/ml for n-acetyl-PAH. The HPLC plasma and urine results obtained for PAH were used to calculate the subject kidney effective renal plasma flow (ERPF) and the iohexol results were used to calculate the subject kidney glomerular filtration rate (GFR). The HPLC results for PAH were then compared to an alternative colorimetric method for analyzing PAH to determine if subject metabolism (acetylation) of PAH affected the ERPF results obtained using the colorimetric method, the subsequent ERPF/GFR ratio and clinical impression of subject patient kidney function. The method was utilized in several different clinical studies evaluating the effect of kidney function from medications (phase IV evaluations) marketed for patients with cardiovascular disease.
Several microbial volatile organic compounds (MVOCs) that can serve as potential chemical markers for microbial contamination in tobacco have been identified. Four different fungal species, Aspergillus niger (AN), A. ornatus (AO), Pencillium chrysogenum (PC) and Rhizopus stolonifer (RS), commonly reported in moldy tobacco were cultured and screened for MVOCs. Because the MVOCs emitted by a microbial species are substrate specific, the fungal strains were separately grown on potato dextrose agar (PDA) and tobacco products. MVOCs from the mold cultures grown on PDA and tobacco products were extracted using closed-loop stripping analysis (CLSA) and identified by gas chromatography/time-of-flight mass spectrometry (GC/TOF-MS). Some of the prominent tobacco mold markers identified by this method include: 1-octen-3-ol; 2-octen-1-ol; 2-methyl-1-butanol; 3-methyl-1-butanol; 1-octene and 2-pentanone. In particular, 1-octen-3-ol was detected in all the mold cultures and moldy tobacco samples analyzed. Olfactory evaluation of 1-octen-3-ol indicated a characteristic musty odor and the odor threshold was determined to be approximately 200 ng/ml. The limits of detection for 1-octen-3-ol using GC/TOF-MS and GC/mass selective detector (MSD) in the full-scan mode and selected ion monitoring (SIM) mode were investigated. The CLSA-GC/TOF-MS demonstrates a fast, sensitive and semi-quantitative analytical technique for screening tobacco materials for the presence of mold via chemical markers of microbial contamination.
A high-performance liquid chromatographic (HPLC) method was developed using solid-phase extraction, o-phthalaldehyde (OPA) derivatization and fluorescence detection for the determination of the direct thrombin inhibitor bivalirudin in human plasma and urine. The use of this assay will facilitate the study of the pharmacodynamics of bivalirudin in studies of special patient populations. A C18 bioanalytical column at a flow rate of 1ml/min with an aqueous trifluoroacetic acid (0.1% TFA in deionized water, pH 2.2, v/v) mobile phase and methanol gradient was used. The assay demonstrated linearity from 3 to 20μg/ml bivalirudin in plasma, with a detection limit of 1μg/ml. The method was utilized in a study evaluating the pharmacokinetic and pharmacodynamic effects of bivalirudin in patients undergoing percutaneous coronary interventions (PCIs).
Losartan is one of several angiotensin-receptor blockers currently in clinical use. Losartan is given as an active prodrug with subsequent conversion to a long-acting E-3174 metabolite. The clearance of losartan in predominantly hepatic whereas its E-3174 metabolite undergoes equal hepatic and renal clearance. To date, although the renal clearance mechanism for losartan/E-3174 have not been delineated the extensive protein binding of both losartan and E-3174 would suggest that tubular secretion is important to the renal eliminatin of both of these substances. This study was designed to evaluate the renal handling of losartan/E-3174 with and without the co-administration of the organic anion transport inhibitor probenecid. 8 healthy males and females were studied in a four-way crossover single losartan dose pharmacokinetic study. Limb A: losartan 100-mg; Limb B: probenecid 500-mg twice daily for 4 days (including the study day) and losartan 100-mg; Limb C: placebo; Limb D:probenecid 500-mg twice daily for two doses. Following losartan dosing on the study day multiple urine and plasma samples were obtained to determine the plasma and urine elimination profile of losartan/E-3174 (* p < 0.001). The study results show a clear decrease in urine excretion of losartan and E-3174 with probenecid co-administration with a parallel rise in the Cmax of each substance. These results are consistent with the hypothesis that losartan and E-3174 are both tubularly secreted by the probeneicd inhibi organic anion secretory pathway. It is highly likely that other organic anion drugs, such as thiazide or loop diuretics, co-secreted by this pathway, will have their time course of urinary delivery altered by losartan/E-3174 in a dose and time-dependent fashion. The relevance of urinary elimination of losartan/E-3174 remains to be determined as to its effect(s) on apically located angiotensin receptors. (See Table)
A simple high-performance liquid chromatographic method was developed for the determination of vanillin and its vanillic acid metabolite in human plasma, red blood cells and urine. The mobile phase consisted of aqueous acetic acid (1%, v/v)-acetonitrile (85:15, v/v), pH 2.9 and was used with an octadecylsilane analytical column and ultraviolet absorbance detection. The plasma method demonstrated linearity from 2 to 100 microg/ml and the urine method was linear from 2 to 40 microg/ml. The method had a detection limit of 1 microg/ml for vanillin and vanillic acid using 5 microl of prepared plasma, red blood cells or urine. The method was utilized in a study evaluating the pharmacokinetic and pharmacodynamic effects of vanillin in patients undergoing treatment for sickle cell anemia.
A simple high performance liquid chromatographic (HPLC) method utilizing narrowbore chromatography was developed for the determination of hydrochlorothiazide in human urine. A mobile phase of 0.1% aqueous acetic acid—acetonitrile (93:7, v/v) pH 3 was used with a C18 analytical column and ultraviolet detection (UV). The method demonstrated linearity from 2 to 50 μg ml−1 using 50 μl of urine with a detection limit of 1 μg ml−1. The method was utilized in a study evaluating if racial differences are present in the pharmacokinetic and pharmacodynamic effects of hydrochlorothiazide.
An improved high-performance liquid chromatographic (HPLC) method utilizing solid-phase extraction (SPE) and midbore chromatography was developed for the determination of ranitidine in human plasma. A mobile phase of 20 mM K2HPO4-acetonitrile-triethylamine (87.9:12.0:0.1, v/v) pH 6.0 was used with a phenyl analytical column and ultraviolet detection (UV). The method demonstrated linearity from 25 to 1000 ng/ml in 500 microliters of plasma with a detection limit of 10 ng/ml. The method was utilized in a pharmacokinetic study evaluating the effects of pancreatico-biliary secretions on ranitidine absorption.
A simple high-performance liquid chromatographic (HPLC) method was developed for the determination of losartan and its E-3174 metabolite in human plasma, urine and dialysate. For plasma, a gradient mobile phase consisting of 25 mM potassium phosphate and acetonitrile pH 2.2 was used with a phenyl analytical column and fluorescence detection. For urine and dialysate, an isocratic mobile phase consisting of 25 mM potassium phosphate and acetonitrile (60:40, v/v) pH 2.2 was used. The method demonstrated linearity from 10 to 1000 ng/ml with a detection limit of 1 ng/ml for losartan and E-3174 using 10 microl of prepared plasma, urine or dialysate. The method was utilized in a study evaluating the pharmacokinetic and pharmacodynamic effects of losartan in patients with kidney failure undergoing continuous ambulatory peritoneal dialysis (CAPD).
A simple gas chromatography (GC) method for the simultaneous determination of halothane, enflurane, and isoflurane in Krebs buffer solution has been developed. The method utilizes methylene chloride as the internal standard and liquid-liquid extraction using chloroform as the solvent. The method demonstrated excellent recovery (100%) of each component and a linear calibration range of 100-700, 100-800, and 300-1,400 micrograms/mL for halothane, isoflurane, and enflurane, respectively. Intra-day accuracy and precision had an error and coefficient of variation of less than 5.1% and 2.7%, respectively.
A novel solid-phase on-line elution HPLC method employing fluorescence detection to measure metolazone in plasma and whole blood has been developed. The method is sensitive and selective for metolazone and linear over a dynamic range of 1–50 ng/ml with a sample requirement of 250 μl. The limit of quantitation for the method is 1 ng/ml and combined intra- and inter-day accuracy and precision had an error and coefficient of variation of 2.9 and 5.5%, respectively.