INTRODUCTION:Performance of medical procedures in spaceflight beyond low Earth orbit (LEO) requires novel solutions to replace real-time ground support, which is hampered by growing communication latencies as distance from Earth increases. The Autonomous Medical Officer Support (AMOS) Software Technology Demonstrations on the International Space Station (ISS) trialed a novel software tool that shifts the emphasis from pre-flight training and real-time remote guidance (current ISS paradigm) to a new standard of multidimensional in-flight just-in-time instruction. The AMOS platform is a skill management tool for all mission phases and currently features comprehensive training and guidance modules for urinary bladder and renal ultrasound examinations. METHODS:Using the AMOS software, two ISS crewmembers performed in-flight bladder and kidney ultrasound examinations with no guidance from the ground and with no pre-flight exposure to the software (n = 2 sessions). Images were graded for clinical quality using a strict evaluation rubric. Software use patterns were recorded, and participants provided both structured and free response feedback. RESULTS:Clinically adequate images were obtained for all but one of the attempted views. Participants rated AMOS as highly useable and primarily used linear navigation. CONCLUSION:Variability in subject anatomy, operator experience, and operator receptiveness to instruction during autonomous examinations is a persistent but manageable limitation. Despite these challenges, here we report the first successful demonstrations of autonomous imaging activities in the operational setting of spaceflight, validating this autonomous guidance proof-of-concept.
These data suggest that the cardiovascular system can accommodate up to 60 min of sustained use of mild levels of LBNP during long-duration spaceflight. There was a single report of mild hypotensive symptoms during use of LBNP by an individual who had low blood pressure prior to the start of the LBNP session. Thus, the absolute arterial blood pressure should be taken into consideration when determining if an LBNP session will be a potential challenge to the cardiovascular system during spaceflight.
Weightlessness induces a cephalad shift of blood and cerebrospinal fluid that may increase intracranial pressure (ICP) during spaceflight, whereas lower body negative pressure (LBNP) may provide an opportunity to caudally redistribute fluids and lower ICP. To investigate the effects of spaceflight and LBNP on noninvasive indicators of ICP (nICP), we studied 13 crewmembers before and after spaceflight in seated, supine, and 15° head-down tilt postures, and at ∼45 and ∼150 days of spaceflight with and without 25 mmHg LBNP. We used four techniques to quantify nICP: cerebral and cochlear fluid pressure (CCFP), otoacoustic emissions (OAE), ultrasound measures of optic nerve sheath diameter (ONSD), and ultrasound-based internal jugular vein pressure (IJVp). On flight day 45, two nICP measures were lower than preflight supine posture [CCFP: mean difference -98.5 -nL (CI: -190.8 to -6.1 -nL), P = 0.037]; [OAE: -19.7° (CI: -10.4° to -29.1°), P < 0.001], but not significantly different from preflight seated measures. Conversely, ONSD was not different than any preflight posture, whereas IJVp was significantly greater than preflight seated measures [14.3 mmHg (CI: 10.1 to 18.5 mmHg), P < 0.001], but not significantly different than preflight supine measures. During spaceflight, acute LBNP application did not cause a significant change in nICP indicators. These data suggest that during spaceflight, nICP is not elevated above values observed in the seated posture on Earth. Invasive measures would be needed to provide absolute ICP values and more precise indications of ICP change during various phases of spaceflight.NEW & NOTEWORTHY The current study provides new evidence that intracranial pressure (ICP), as assessed with noninvasive measures, may not be elevated during long-duration spaceflight. In addition, the acute use of lower body negative pressure did not significantly reduce indicators of ICP during weightlessness.
Importance While 6-month data are available regarding spaceflight-associated neuro-ocular syndrome, manned missions for 1 year and beyond are planned, warranting evaluation for spaceflight-associated neuro-ocular syndrome beyond 6 months. Objective To determine if the manifestation of spaceflight-associated neuro-ocular syndrome worsens during International Space Station missions exceeding the present 4- to 6-month duration. Design, Setting, and Participants The One-Year Mission Study used quantitative imaging modalities to investigate changes in ocular structure in 2 crew members who completed a 1-year-long spaceflight mission. This study investigated the ocular structure of crew members before, during, and after their mission on the International Space Station. Two crew members participated in this study from March 2015 to September 2016. Analysis began in March 2015 and ended in May 2020. Exposures Crew members were tested before, during, and up to 1 year after spaceflight. Main Outcomes and Measures This study compares ocular changes (peripapillary retinal edema, axial length, anterior chamber depth, and refraction) in two 1-year spaceflight mission crew members with cohort crew members from a 6-month mission (n = 11). Minimum rim width (the shortest distance between Bruch membrane opening and the internal limiting membrane) and peripapillary total retinal thickness were measured using optical coherence tomography. Results Both crew members were men. Minimum rim width and total retinal thickness increased in both participants throughout the duration of spaceflight exposure to the maximal observed change from preflight (minimum rim width: participant 1, 561 [+149 from preflight] μm at flight day 270; participant 2, 539 [+56 from preflight] μm at flight day 270; total retinal thickness: participant 1, 547 [+135 from preflight] μm at flight day 90; participant 2, 528 [+45 from preflight] μm at flight day 210). Changes in peripapillary choroid engorgement, axial length, and anterior chamber depth appeared similar between the 1-year mission participants and a 6-month mission cohort. Conclusions and Relevance This report documents the late development of mild optic disc edema in 1 crew member and the progressive development of choroidal folds and optic disc edema in another crew member over the duration of 1 year in low Earth orbit aboard the International Space Station. Previous reports characterized the ocular risk associated with 4 to 6 months of spaceflight. As future spaceflight missions are planned to increase in duration and extend beyond low Earth orbit, further observation of astronaut ocular health on spaceflight missions longer than 6 months in duration may be warranted.
Spaceflight induces a chronic headward fluid shift that is believed to underlie ocular changes observed in astronauts. The present study demonstrates, for the first time, that reversing this headward fluid shift via application of lower body negative pressure (LBNP) during spaceflight may alter the ocular venous system, as evidenced by a decrease in intraocular pressure. This finding indicates that LBNP has the potential to be an effective countermeasure against the headward fluid shift during spaceflight, which may then be beneficial in preventing or reversing associated ocular changes.
As a weightlessness-induced headward fluid shift is hypothesized to be a primary factor underlying several physiological consequences of spaceflight, countermeasures aimed at reversing the fluid shift will likely be crucial during exploration-class spaceflight missions. Here, we tested three mechanical countermeasures individually and in various combinations to reduce a posture-induced headward fluid shift as a ground-based spaceflight analog.
Cephalad fluid shifts in space have been hypothesized to cause the spaceflight-associated neuro-ocular syndrome (SANS) by increasing the intracranial-ocular translaminal pressure gradient. Lower body negative pressure (LBNP) can be used to shift upper-body blood and other fluids toward the legs during spaceflight. We hypothesized that microgravity would increase jugular vein volume (JVvol), portal vein cross-sectional area (PV), and intracranial venous blood velocity (MCV) and that LBNP application would return these variables toward preflight levels. Data were collected from 14 subjects (11 males) before and during long-duration International Space Station (ISS) spaceflights. Ultrasound measures of JVvol, PV, and MCV were acquired while seated and supine before flight and early during spaceflight at day 45 (FD45) and late at day 150 (FD150) with and without LBNP. JVvol increased from preflight supine and seated postures (46 +/- 48% and 646 +/- 595% on FD45 and 43 +/- 43% and 702 +/- 631% on FD150, P < 0.05), MCV increased from preflight supine (44 +/- 31% on FD45 and 115 +/- 116% on FD150, P < 0.05), and PV increased from preflight supine and seated (51 +/- 56% on FD45 and 100 +/- 74% on FD150, P < 0.05). lnflight LBNP of 25 mmHg restored JVvol and MCV to preflight supine level and PV to preflight seated level. Elevated JVvol confirms the sustained neck-head blood engorgement inflight, whereas increased PV area supports the fluid shift at the splanchnic level. Also, MCV increased potentially due to reduced lumen diameter. LBNP, returning variables to preflight levels, may be an effective countermeasure. NEW & NOTEWORTHY Microgravity-induced fluid shifts markedly enlarge jugular and portal veins and increase cerebral vein velocity. These findings demonstrate a marked flow engorgement at neck and splanchnic levels and may suggest compression of the cerebral veins by the brain tissue in space. LBNP (-25 mmHg for 30 min) returns these changes to preflight levels and, thus, reduces the associated flow and tissue disturbances.
Spaceflight-associated neuro-ocular syndrome (SANS) is a human spaceflight risk recognized by NASA. Elevated intracranial pressure (ICP) has been implicated as a root cause of many SANS signs and symptoms, yet there is no reliable noninvasive means of monitoring ICP. We have developed a noninvasive method of monitoring ICP change that exploits ear canal acoustic and otoacoustic emission (OAE) measurements. Changed ICP alters pressure in the inner ear, leading to changes in the tension and position of middle ear (ME) components; tension of these components determines the phase of the stimulus in the ear canal and the OAE response sound transmission back through the ME. The OAE method has been validated in several studies, including our own experiments as part of the NASA Fluid Shifts study. Systematic OAE phase changes demonstrating increased ME tension (an ICP indicator) are observed as posture is changed from seated to supine to head-down tilt (HDT). This effect can be substantially mitigated by lower body negative pressure (LBNP). The OAE technique has also been used on International Space Station (ISS) crewmembers, providing evidence that ICP in microgravity is similar to that seen on the ground in the supine position. The OAE method is also a rapid and noninvasive means of assessing the effectiveness of SANS countermeasures. Here we report results from two studies which used OAEs. In the most recent study (Venous Congestion Countermeasures - VCCM), three promising countermeasures [LBNP, an impedance threshold device (ITD), and veno-occlusive thigh cuffs (VTC)] were applied individually and in combination. In our previous ITD-only study, ITD was investigated for its ability to reduce ICP and cephalic venous congestion in supine and various HDT postures. Internal jugular vein (IJV) ultrasound showed a clear decongestive effect at all postures, however OAE data showed that ITD only caused a phase decrease (tension decrease) in HDT postures. In supine, ITD appeared to INCREASE tension. This paradox leads us to hypothesize that the OAE method is not accurately representing ICP changes with countermeasures (CM), which can alter ME tension through other means, such as ME pressure (MEP) changes. More generally, the exact mechanism for observed OAE response and stimulus phase shifts are not clearly understood, specifically with regard to the effects of MEP. The VCCM study examined the effects of externally-applied MEP on OAE recordings to document the relationship between these parameters. Analysis of these data provide new insights to these OAE mechanisms, in addition to results on CM effectiveness.
To understand the health impact of long-duration spaceflight, one identical twin astronaut was monitored before, during, and after a 1-year mission onboard the International Space Station; his twin served as a genetically matched ground control. Longitudinal assessments identified spaceflight-specific changes, including decreased body mass, telomere elongation, genome instability, carotid artery distension and increased intima-media thickness, altered ocular structure, transcriptional and metabolic changes, DNA methylation changes in immune and oxidative stress-related pathways, gastrointestinal microbiota alterations, and some cognitive decline postflight. Although average telomere length, global gene expression, and microbiome changes returned to near preflight levels within 6 months after return to Earth, increased numbers of short telomeres were observed and expression of some genes was still disrupted. These multiomic, molecular, physiological, and behavioral datasets provide a valuable roadmap of the putative health risks for future human spaceflight.
IMPORTANCE Exposure to a weightless environment during spaceflight results in a chronic headward blood and tissue fluid shift compared with the upright posture on Earth, with unknown consequences to cerebral venous outflow. OBJECTIVES To assess internal jugular vein (IJV) flow and morphology during spaceflight and to investigate if lower body negative pressure is associated with reversing the headward fluid shift experienced during spaceflight. DESIGN, SETTING, AND PARTICIPANTS This prospective cohort study included 11 International Space Station crew members participating in long-duration spaceflight missions. Internal jugular vein measurements from before launch and approximately 40 days after landing were acquired in 3 positions: seated, supine, and 15 degrees head-down tilt. In-flight IJV measurements were acquired at approximately 50 days and 150 days into spaceflight during normal spaceflight conditions as well as during use of lower body negative pressure. Data were analyzed in June 2019. EXPOSURES Posture changes on Earth, spaceflight, and lower body negative pressure. MAIN OUTCOMES AND MEASURES Ultrasonographic assessments of IJV cross-sectional area, pressure, blood flow, and thrombus formation. RESULTS The 11 healthy crew members included in the study (mean [SD] age, 46.9 [6.3] years, 9 [82%] men) spent a mean (SD) of 210 (76) days in space. Mean IJV area increased from 9.8 (95% CI, -1.2 to 20.7) mm(2) in the preflight seated position to 70.3 (95% CI, 59.3-81.2) mm(2) during spaceflight (P < .001). Mean IJV pressure increased from the preflight seated position measurement of 5.1 (95% CI, 2.5-7.8) mm Hg to 21.1 (95% CI, 18.5-23.7) mm Hg during spaceflight (P < .001). Furthermore, stagnant or reverse flow in the IJV was observed in 6 crew members (55%) on approximate flight day 50. Notably, 1 crew member was found to have an occlusive IJV thrombus, and a potential partial IJV thrombus was identified in another crew member retrospectively. Lower body negative pressure was associated with improved blood flow in 10 of 17 sessions (59%) during spaceflight. CONCLUSIONS AND RELEVANCE This cohort study found stagnant and retrograde blood flow associated with spaceflight in the IJVs of astronauts and IJV thrombosis in at least 1 astronaut, a newly discovered risk associated with spaceflight. Lower body negative pressure may be a promising countermeasure to enhance venous blood flow in the upper body during spaceflight.
OBJECTIVE:The objective is enhanced ophthalmic ultrasound imaging to monitor ocular structure and intracranial dynamics changes related to visual impairment and intracranial pressure (ICP) induced by microgravity. The goals are to improve the ease of use and reduce operator variability by automatically rendering improved views of the anatomy and deriving new metrics of the morphology and dynamics.MATERIALS AND METHODS:A prototype three-dimensional (3-D) probe was integrated onto a portable ultrasound scanner. Image analysis algorithms were developed to automatically detect the ocular anatomy and simultaneously render views of the optic nerve with improved sheath definition. Curvature metrics were calculated from 3-D retinal surfaces to quantify posterior globe flattening, and tissue velocity waveforms of the optic nerve were analyzed to assess intracranial dynamics.RESULTS:New 3-D structural measurements were evaluated in a head-down tilt study. The response of optic nerve sheath and globe flattening metrics were quantified in 11 healthy volunteers from baseline to moderately elevated ICP. The optic nerve measurements showed good correlation with existing two-dimensional (2-D) methods and an acute response to increased ICP, while globe flattening did not show an acute response. The tissue velocities were evaluated in a porcine model from baseline to significantly elevated ICP and correlated with invasive ICP readings in four animals.CONCLUSIONS:Volumetric ophthalmic imaging was demonstrated on a portable ultrasound system and structural measurements validated with existing methods. New 3-D structural measurements and dynamic measurements were evaluation during in vivo studies. Further investigations are needed to evaluate improvements in performance for non-experts and application to clinically relevant conditions.
BACKGROUND:Back pain is a common complaint during spaceflight that is commonly attributed to intervertebral disc swelling in microgravity. Ultrasound (US) represents the only imaging modality on the International Space Station (ISS) to assess its etiology. The present study investigated: 1) The agreement and correlation of spinal US assessments as compared to results of pre- and postflight MRI studies; and 2) the trend in intervertebral disc characteristics over the course of spaceflight to ISS.METHODS:Seven ISS astronauts underwent pre- and postflight US examinations that included anterior disc height and anterior intervertebral angles with comparison to pre- and postflight MRI results. In-flight US images were analyzed for changes in disc height and angle. Statistical analysis included repeated measures ANOVA with Bonferroni post hoc analysis, Bland-Altman plots, and Pearson correlation.RESULTS:Bland-Altman plots revealed significant disagreement between disc heights and angles for MRI and US measurements while significant Pearson correlations were found in MRI and US measurements for lumbar disc height (r2 = 0.83) and angle (r2 = 0.89), but not for cervical disc height (r2 = 0.26) or angle (r2 = 0.02). Changes in anterior intervertebral disc angle-initially increases followed by decreases-were observed in the lumbar and cervical spine over the course of the long-duration mission. The cervical spine demonstrated a loss of total disc height during in-flight assessments (∼0.5 cm).DISCUSSION:Significant disagreement but significant correlation was noted between US and MRI measurements of disc height and angle. Consistency in imaging modality is important for trending measurements and more research related to US technique is required.Harrison MF, Garcia KM, Sargsyan AE, Ebert D, Riascos-Castaneda RF, Dulchavsky SA. Preflight, in-flight, and postflight imaging of the cervical and lumbar spine in astronauts. Aerosp Med Hum Perform. 2018; 89(1):32-40.
Objectives-Back pain is one of the most common conditions of astronauts during spaceflight and is hypothesized to be attributed to pathologic anatomic changes. Ultrasound (US) represents the only available imaging modality on the International Space Station, but a formal US protocol for imaging the structures of the spinal column does not exist. This investigation developed a method of acquiring diagnostic-quality images of the anterior lumbar and cervical regions of the spine during long-duration spaceflight. Methods-Comprehensive spinal US examinations were conducted on 7 long-duration spaceflight astronauts before flight, in flight, and after flight and compared to preflight and postflight magnetic resonance imaging data. In-flight scans were conducted after just-in-time training assisted by remote expert tele-US guidance. Results-Novice users were able to obtain diagnostic-quality spinal images with a 92.5% success rate. Thirty-three anomalous or pathologic findings were identified during the preflight US analysis, and at least 14 new findings or progressions were identified during the postflight US analysis. Common findings included disk desiccation, osteophytes, and qualitative changes in the intervertebral disk height and angle. Conclusions-Ultrasound has proven efficacy as a portable and versatile diagnostic imaging modality under austere conditions. We demonstrated a potential role for US to evaluate spinal integrity and alterations in the extreme environment of space on the International Space Station. Further investigations should be performed to corroborate this imaging technique and to create a larger database related to in-flight spinal conditions during long-duration spaceflight.
INTRODUCTION: This project will provide critical data required to objectively determine how an optimized thigh cuff could be incorporated into the NASA integrated physiological countermeasure suite. This project will determine if thigh cuffs used during simulated spaceflight impact intracranial pressure (ICP), ocular structure and function, and intraocular pressure (IOP) using state of-the-art techniques. Additionally, some of the same methods, hardware, and protocols will be employed in the present investigation to enable direct comparisons to the International Space Station (ISS) Fluid Shifts experiment with Chibis-Lower Body Negative Pressure (LBNP). This study will determine the temporal physiological responses of thigh cuff application and removal on ocular and cerebral variables (including invasive ICP) in a microgravity analog. Furthermore, this proposed study will determine tissue pressure distribution applied by thigh cuffs in order to improve comfort, mobility, and efficacy of the countermeasure. Our specific aim is to determine the efficacy of a novel thigh cuff device to mitigate cephalad fluid shifts. We hypothesize that a thigh cuff countermeasure employed in a microgravity analog will temporarily reverse or attenuate ocular and cerebral-volume-pressure variables, approaching normal Earth-based seated posture, the most frequent posture assumed in daily life. In addition, we hypothesize that the magnitude of fluid and pressure redistribution using a thigh cuff countermeasure may require a longer exposure time than that of Chibis-LBNP (using ground-based data from our Fluid Shifts project). This project directly addresses Critical Path Roadmap Risks and Questions regarding Risk of Spaceflight-Induced Intracranial Hypertension/Vision Alterations, and IRP Gap VIIP13: We need to identify preventative and treatment countermeasures to mitigate changes in ocular structure and function and intracranial pressure during spaceflight. METHODS: Noninvasive measures and tissue pressure distributions beneath thigh cuffs The objectives of this study are to: 1) determine the distribution of skin surface pressures beneath the advanced thigh cuff in ten subjects, 2) calibrate the built-in pressure measurement system of the advanced thigh cuff using an industry standard device, and 3) collect subjective feedback and data on the new cuff design to allow for further adjustments prior to invasive studies. A Tekscan Industrial Sensing (I-Scan) system will measure the pressure distribution of the advanced thigh cuff against the skin. In addition, we will measure blood pooling in the thigh and record the circumference of the thigh using Hokanson strain gauge plethysmography. The advanced thigh cuff will be adjusted to obtain a skin contact pressure of 30-50 mmHg as visualized on the Tekscan system. The built-in advanced thigh cuff pressure monitor will be recorded simultaneously to allow direct comparison to the Tekscan measurements. The volunteer will then remove the thigh cuff and remain at rest for five minutes with no legging applied. The thigh cuff will be donned again and pressure measurements will be taken in the same manner for up to 10 repetitions to show reproducibility of pressure after donning. At the conclusion of the study, subjects will be asked to flex their knee, stand, walk, and sit with the thigh cuff activated. During each of these maneuvers the subject will rate their pain/comfort using a modified Borg scale. Effect of thigh cuffs on ICP during simulated microgravity Ommaya reservoir patients will be recruited from the John Wayne Cancer Institute. Ommaya reservoirs provide safe and direct access for the measurement of ICP. Subjects will be instrumented for continuous blood pressure, ECG, and invasive ICP measures. The subjects will be positioned in the upright sitting posture for a 10-minute stabilization period. After the 10-minute stabilization period, imaging measures [ICP, Optical Coherence Tomography, IOP, ocular and vascular ultrasound] will be performed. Following baseline seated measures, the subject will be positioned randomly in the supine, 15deg head-down-tilt, and 15deg head-down-tilt with thigh cuffs and measures repeated. DISCUSSION: Tests to down-select thigh cuff designs will occur in early 2016. Invasive ICP and noninvasive eye imaging tests will begin in spring 2016. Supported by NSBRI through NCC 9-58.
BACKGROUND: Remote-guidance (RG) techniques aboard the International Space Station (ISS) have enabled astronauts to collect diagnostic-level ultrasound (US) images. Exploration-class missions will likely require nonformally trained sonographers to operate with greater autonomy given longer communication delays (> 6 s for missions beyond the Moon) and blackouts. Training requirements for autonomous collection of US images by non-US experts are being determined.METHODS: Novice US operators were randomly assigned to one of three groups to collect standardized US images while drawing expertise from A) RG only, B) a computer training tool only, or C) both RG and a computer training tool. Images were assessed for quality and examination duration. All operators were given a 10-min standardized generic training session in US scanning. The imaging task included: 1) bone fracture assessment in a phantom and 2) Focused Assessment with Sonography in Trauma (FAST) examination in a healthy volunteer. A human factors questionnaire was also completed.RESULTS: Mean time for group B during FAST was shorter (20.4 vs. 22.7 min) than time for the other groups. Image quality scoring was lower than in groups A or C, but all groups produced images of acceptable diagnostic quality.DISCUSSION: RG produces US images of higher quality than those produced with only computer-based instruction. Extended communication delays in exploration missions will eliminate the option of real-time guidance, thus requiring autonomous operation. The computer program used appears effective and could be a model for future digital US expertise banks. Terrestrially, it also provides adequate self-training and mentoring mechanisms.
Background: Changes in the lumbar and sacral spine occur with exposure to microgravity in astronauts; monitoring these alterations without radiographic capabilities on the International Space Station (ISS) requires novel diagnostic solutions to be developed. Study Objectives: We evaluated the ability of point-of-care ultrasound, performed by nonexpert-operator astronauts, to provide accurate anatomic information about the spine in long-duration crewmembers in space. Methods: Astronauts received brief ultrasound instruction on the ground and performed inflight cervical and lumbosacral ultrasound examinations using just-in-time training and remote expert tele-ultrasound guidance. Ultrasound examinations on the ISS used a portable ultrasound device with real-time communication/guidance with ground experts in Mission Control. Results: The crewmembers were able to obtain diagnostic-quality examinations of the cervical and lumbar spine that would provide essential information about acute or chronic changes to the spine. Conclusions: Spinal ultrasound provides essential anatomic information in the cervical and lumbosacral spine; this technique may be extensible to point-of-care situations in emergency departments or resource-challenged areas without direct access to additional radiologic capabilities. (C) 2014 Elsevier Inc.