A liquid chromatography method using volatile ion-pairing reagents and tandem mass spectrometry was developed to obviate observed matrix effect for ionizable polar compounds. The present study investigated the addition of volatile ion-pair reagents to the reconstitution solution instead of the mobile phase to enhance the efficiency of chromatographic separation and minimize the sensitivity loss due to the formation of ion-pairs. The volatile ion-pair reagents used were perfluorinated carboxylic acids with n-alkyl chains: heptafluorobutanoic acid (HFBA), nonafluoropentanoic acid (NFPA), tridecafluoroheptanoic acid (TDFHA) and pentadecafluorooctanoic acid (PDFOA). The model analytes evaluated were N-methylnicotinamide (MNA) chloride, N-methyl 2-pyridone 5-carboxamide (2PY) and phenylephrine. The effects of alkyl chain length and the concentrations of the ion-pair reagents on the retention of analytes were studied, as well as the effect of pH on the retention of phenylephrine. The volatile ion-pair reagents in the reconstitution solution showed significant effect on the retention of the ionizable polar compounds, and the sensitivity of detection was improved for plasma samples through decreasing the matrix effect. This methodology was successfully applied to establish a quantitative assay for the polar drug substance methadone in human plasma with a concentration range from 0.1 to 50 ng/mL. Ion-pair reagents not only shifted the retention time but also reduced the carry-over peak for methadone.
In the progression from drug discovery to development, not only pharmacokinetic (PK) characterization needed for lead compound selection often becomes a rate-limiting step, but also high volume of routine sample analysis ensued from numerous required biodisposition studies for the lead compounds and their back-ups often place a burdensome hurdle to the throughput of IND and NDA development phases. Higher throughput of PK screening via cocktail dosing has been reported to accelerate PK screening in the discovery phase. However, concerns on drug-drug interactions and other limitations associated with the cocktail M-in-One dosing (multiple compounds per dose per animal) has prompted the present investigation of sample pooling alongside One-in-One dosing strategy (one compound per dose per animal) as an alternative to the cocktail dosing approach. Using traditional HPLC for bioanalysis as an example, the present study illustrate the concept and usefulness of sample pooling that could facilitate the throughput of PK screening and characterization in both discovery and development phases. Six proprietary dopamine D4 receptor antagonist preleads representing three different chemical classes, used as model compounds (C1-C6), were administered orally to rats. One rat received one compound and three rats were used for each compound. Six unknown plasma samples from six different rats at each time point were pooled. The pooled plasma samples were extracted by a one-step liquid-liquid extraction and concentrations of the six preleads were quantitated simultaneously. By sample pooling, a substantial amount of PK information was obtained at the same time for the six preleads, which requires much less workload than when bioanalysis is dealt with one compound at a time. For the first time in one aspect of innovative bioanalysis, the present investigation has demonstrated that sample pooling following One-in-One dosing can be utilized to enhance the throughput rate in PK screening in discovery phase. The sample pooling approach is likely to be useful in enhancing the throughput of PK characterization in development phase. With the advent of LC-MS and its becoming user-friendly, where separation of drug compounds is no longer an issue, the uniqueness of sample pooling may also pose a new way of thinking in regard to the old ways of handling bioanalysis for traditional PK research.
The activity of a selective tachykinin NK1 receptor antagonist, PD 154075 ([(2-benzofuran)-CH2OCO]-(R)-alpha-MeTrp-(S)-NHCH(CH3) Ph), was examined in radioligand binding studies, in a [Sar9,Met(O2)11]substance P-induced foot-tapping model in the gerbil, and in cisplatin-induced acute and delayed emesis in the ferret. In radioligand binding studies, PD 154075 showed nanomolar affinity for the human, guinea-pig, gerbil, dog and ferret NK1 receptors with an approximate 300 times lower affinity for the rodent NK1 receptor. Using NK2,NK3 receptors and a range of other receptor ligands, PD 154075 was shown to exhibit a high degree of selectivity and specificity for the human type NK1 receptor. Following subcutaneous administration PD 154075 dose dependently (1-100 mg/kg) antagonised the centrally mediated [Sar9,Met(O2)11] substance P-induced foot tapping in the gerbil with a minimum effective dose (MED) of 10 mg/kg. The ability of PD 154075 to readily penetrate into the brain following oral administration was confirmed by its extraction and high performance liquid chromatography assay from the rat brain. PD 154075 was shown to achieve a relatively fast and sustained brain concentration (brain/plasma ratios ranged from 0.27 to 0.41 during the time period of 0.25-12 h). Further pharmacokinetic studies revealed that the absolute oral bioavailability of PD 154075 in the rat was (mean +/- S.D.) 49 +/- 15%. PD 154075 (1-30 mg/kg, i.p.) dose dependently antagonised the acute vomiting and retching in the ferret measured for 4 h following administration of cisplatin (10 mg/kg, i.p.) with a MED of 3 mg/kg. The administration of a lower dose of cisplatin (5 mg/kg, i.p.) in the ferret induces both an acute (day 1) and delayed (days 2 and 3) phase of emesis. The i.p. administration of PD 154075, 10 mg/kg three times a day for 3 days, almost completely blocked both the acute and delayed emetic responses. In the same study, the 5-HT3 receptor antagonist ondansetron (1 mg/kg, i.p., t.i.d.) was also very effective against the acute emetic response observed during the first 4 h following cisplatin, but it was only weakly active against the delayed response. In conclusion, PD 154075 is a selective and specific high affinity NK1 receptor antagonist with good oral bioavailability which is effective against both acute and delayed emesis induced by cisplatin in the ferret.
The clearance of human epidermal growth factor (hEGF1-53) has been thought to be mediated mainly by a high-capacity receptor system, yet relatively low in vivo clearance rates (<10 mL/min/kg) and long terminal elimination half-lives (>120 min) have been observed in rats receiving the peptide that was iodinated by the oxidative chloramine-T (CT) method. We investigated if a mild, less oxidative iodination by the lactoperoxidase (Enzymobeads, EB) method, which is known to yield an iodinated peptide with receptor-binding equivalence, could produce a labeled peptide that behaves pharmacokinetically similar to the native material. For comparison, a parallel study was also conducted with EB-125I-hEGF1-48, which in its native form has a much reduced receptor binding activity due to the loss of the C-terminal pentapeptide. Plasma radioactivity concentrations were determined by trichloroacetic acid (TCA) precipitation and immunoprecipitation. Rats cleared unlabeled hEGF1-53 and hEGF1-48 markedly faster (CL(tot) > 120 mL/min/kg) than their radiolabeled counterparts. Approximately 96% of the hEGF1-53 dose was cleared during the initial phase (0-4 min), as opposed to only 5-14% for the iodinated peptide. Similar change was also observed for EB-125I-hEGF1-48 and CT-125I-hEGF1-53. The pharmacokinetic behavior of EB-125I-hEGF1-53 was, in fact, comparable to that of CT-125I-hEGF1-53. These observations indicate that receptor-binding equivalence does not have direct relationship with in vivo EGF clearance. Both iodination methods (oxidative CT and less oxidative EB) might have perturbed one or more steps in the cascade of ligand-receptor internalization and intracellular procession, which in turn modified the disposition of the peptides. In addition, the two independent precipitation techniques for the same peptide generated different kinetic outcomes. The overall experimental results suggest that it is unacceptable to use an iodinated form to characterize the disposition of peptides/proteins like EGF with a specific receptor system mediating its clearance.
Two HPLC assays were developed and validated for simultaneous quantitation of two sulfate metabolites, PD 163637 (VI) and PD 163639 (VIII), of an investigational antipsychotic drug CI-1007 (I) in monkey plasma and urine. VI and VIII were identified as major metabolites in monkey plasma, and both were excreted in urine. Monkey plasma samples were directly injected after deproteinization, and urine samples were analyzed after a clean-up procedure using methyl-tert.-butyl ether. Liquid chromatographic separation was achieved on a Zorbax RX C8 analytical column using gradient elution. Column effluent was monitored using fluorescence detection with excitation and emission wavelengths of 254 and 330 nm, respectively. Minimum quantitation limit was 50 ng/ml in plasma and 100 ng/ml in urine. Linearity was demonstrated up to 3000 ng/ml in plasma and urine. Recoveries of the analytes from plasma and urine were greater than 85%. The assay has been applied to the determination of VI and VIII in plasma and urine samples from monkeys receiving oral administration of I.
Recent scientific and regulatory interest in lacteal excretion of drugs has prompted this review of bioanalytical sample preparation techniques for milk. The composition and properties of milk are reviewed, with emphasis on how the sample preparation is affected. The most important principals of mammary gland pharmacology, including protein binding, ion trapping and liquid solubility, are described. Because adequate milk volume is difficult to obtain from some smaller rodent species, special arrangements for sample collection, control preparation and assay standardization often need to be made. Several commonly-used sample preparation approaches for drugs in milk, including direct injection, dialysis and ultrafiltration, protein precipitation, liquid-liquid extraction, solid-phase extraction and immunoaffinity extraction, have been reported with varying degrees of success. The advantages and disadvantages of each of these approaches is discussed.
Purpose. To study the pharmacokinetics (PK) and pharmacodynamics (PD) of an investigational antipsychotic agent, CI-1007, in rats and monkeys.
Cam-2445 is a selective, high-affinity NK1 receptor antagonist that is a potentially useful treatment for arthritis, asthma, migraine, anxiety, psychosis, and emesis. Cam-2445 exhibits low aqueous solubility and high lipophilicity and has a molecular weight of 470. Cam-2445 has poor oral bioavailability and the purpose of this research was to examine the potential barriers to the oral bioavailability of Cam-2445. Cam-2445 was relatively stable at 37 degrees C in 0.1 N HCl, 5 microM alpha-chymotrypsin, rat intestinal perfusate, and in rat jejunal brush border membrane suspension. High permeability was observed from CACO-2 cells and from rat single-pass intestinal perfusions. Cam-2445 was administered as a solution to rats by intravenous (i.v.), oral (p.o.), intraduodenal (i.d.), and intraportal (i.p.v.) routes. The total oral bioavailability was poor at 1.4%. Absorption appeared to be rapid after i.d. dosing; bioavailability was 26%, and 54% of the dose was absorbed intact into the portal system. After i.p.v. dosing, 48% of the dose was available to the systemic circulation. The elimination t1/2 after i.d. dosing (2.91 h) was comparable to that i.v. dosing (2.93 h), whereas it was significantly longer after p.o. dosing (12.4 h). The p.o. dose apparently precipitated in the gastrointestinal (GI) tract, resulting in low oral bioavailability. These results indicated that neither stability in the GI tract nor membrane transport were major obstacles to the absorption of Cam-2445. While hepatic extraction of 52% was significant, the low aqueous solubility of Cam-2445, as well as the differences noted between p.o. and i.d. studies, strongly support GI dissolution and/or precipitation as the limiting factor for the oral bioavailability of the compound.
SIZEMORE, N., D.S. WRIGHT, W.T. MUELLER AND B.-S. KUO. Impact of receptor downregulation on clearance of two human EGFs with different receptor binding activity. PEPTIDES 17(7) 1229–1236, 1996.—Human epidermal growth factor [hEGF(1–53)] has been thought to be cleared mainly via an EGF receptor (EGFR) endocytosis pathway. Pretreatment of rats with hEGF(1–53) has been shown previously to cause a dramatic reduction in clearance of the peptide contributable to EGFR downregulation. The impact of receptor downregulation has raised concerns for rational design of dosage regimen for this potential wound-healing therapeutic peptide. However, following a similar protocol, we could not reproduce the dramatic reduction in clearance reported previously mediated by an IV bolus acute dose. As EGFR downregulation may be sensitive to the length of exposure and to the activation of the receptor tyrosine kinase activity, two other pretreatment protocols were also evaluated: a 4-h IV infusion (prolonged exposure) of the peptide and an IV bolus of a potent synthetic kinase inhibitor pretreatment were evaluated for effects on clearance. However, neither pretreatment affected the peptide's clearance profile. Further, no effects on clearance and other kinetic parameters were observed for any pretreatment paradigms with a truncated analogue hEGF(1–48), whose EGF receptor binding activity is much weaker but plasma clearance is much higher than hEGF(1–53). In addition, a study in a second rat strain showed no difference in clearance profile of hEGF(1–53) following pretreatment. Results of the present investigation suggest that receptor binding does not have a direct relationship with plasma clearance, and that the EGF clearance mechanisms is highly refractory with EGF receptors possibly recovering rapidly from downregulation through the recycling process. Copyright © 1996 Elsevier Science Inc.
Clearance of human epidermal growth factor (hEGF1-53) has been proposed to be mediated by a receptor pathway involving a typical cascade of ligand-receptor endocytosis and lysosomal degradation. Deletion of the C-terminal pentapeptide from hEGF1-53, which yields hEGF1-48, is known to be associated with a marked reduction in receptor binding. We defined the intravenous (iv)-bolus (acute exposure) and the iv-infusion (prolonged exposure) pharmacokinetics of hEGF1-53 and hEGF1-48 in rats to investigate the impact of the deletion of C-terminal pentapeptide on the EGF clearance using a validated, sensitive ELISA method for quantitation of the peptides in plasma. Both peptides at the low iv bolus dose of 10 micrograms/kg were cleared from plasma with unusually high clearances (CLtot: 128 +/- 31 ml/min/kg for hEGF1-53 and 168 +/- 47 ml/min/kg for hEGF1-48), which are virtually complete within 4-min postdose, and the difference in the overall pharmacokinetics is of minor significance. A 10-fold increase in bolus dose to 100 micrograms/kg decreased clearances 3- to 6-fold, indicating a nonlinear kinetics for both peptides; however, hEGF1-48 was cleared (52 +/- 11 ml/min/kg) 2.5-fold faster than hEGF1-53. A similar nonlinear kinetics was also noticed for both peptides when they were administered by a 2-hr iv infusion at 30 and 300 micrograms/kg doses. hEGF1-48 at the low and high infusion doses was cleared at 126 +/- 16 and 33.7 +/- 14.5 ml/min/kg, respectively, which are 4-fold greater than the corresponding clearance rates of hEGF1-53. These observations suggest that a) deletion of C-terminal pentapeptide is associated with a faster clearance of the growth factor and b) the receptor clearance pathway may be more sensitive to saturation with hEGF1-53 than with hEGF1-48 at low microgram dose levels. hEGF1-53 at the low infusion dose of 30 micrograms/kg was cleared (32.1 +/- 6.2 ml/min/kg) 4-fold slower in comparison with the low bolus dose of 10 micrograms/kg, indicating a remarkable injection mode-dependent disposition kinetics for hEGF1-53, which does not exist for hEGF1-48. The overall results suggest that deletion of C-terminal pentapeptide leads to faster clearance of the growth factor, and the degree of the impact of deletion of C-terminal pentapeptide on the global pharmacokinetics is also dependent on the length of exposure of the receptor to the ligand. The negative relationship between receptor binding and plasma clearance for the two peptides remains to be elucidated at the molecular and receptor levels.
CAM 4515 and CAM 4750 are new nonpeptide tachykinin NK1 receptor antagonists with different lipophilicities. Two separate, simple, and sensitive HPLC methods for the quantitation of these two compounds in plasma and the evaluation of their oral bioavailability in rats were developed and validated. Extraction of CAM 4515 from plasma involved protein precipitation with acetonitrile, while that for CAM 4750 involved a one-step liquid-liquid extraction with methylene chloride. The analytes in extracts were chromatographed on a C18 column using two different separation buffers, 47% 0.02 M sodium citrate (pH 3.5)-53% acetonitrile for CAM 4515 and 59% 0.02 M potassium phosphate dibasic (pH 7.0)-41% acetonitrile for CAM 4750, and both compounds were detected by fluorescence (excitation 278 nm; emission 342 nm). Stability profiles of both drugs at -20 degrees C or room temperature in plasma and in reconstituted buffers were good. The limit of quantitation for both drugs was 5 ng ml-1 with good linearity from 5 to 1000 ng ml-1 using 100-200 microliters of plasma. Excellent precision (relative standard deviation < 8.3%) and accuracy (relative error +/- 9.2%) were observed for both CAM 4515 and CAM 4750. Oral bioavailability studies were conducted for each compound in rats receiving a p.o. dose of 20 mg kg-1 and an i.v. dose of 5 mg kg-1. The absolute oral bioavailability of CAM 4750 (80%) was estimated to be 40-fold greater than that of CAM 4515 (2%). The experimental results suggest that incorporation of a pyridine group into the structural backbone may greatly improve bioavailability.
Purpose. The purpose of the present investigation was to develop and validate two separate enzyme-linked immunosorbent assays (ELISA) for quantitation of exogenous human epidermal growth factor (hEGFl -53) and its truncated fragment (hEGFl-48) in rat plasma.
An automated solid-phase extraction method development system, utilizing a Zymate XP robot and a custom-designed solid-phase extraction manifold, has been developed and validated. This system spikes blank liquid matrix, such as plasma, with solutions containing drug, internal standard, and up to three metabolites. Samples are then buffered or diluted with an appropriate reagent. After these samples and corresponding blanks have been prepared, solid-phase cartridges containing selected sorbents are automatically conditioned. Samples are robotically vortexed and transferred to the conditioned cartridges, and analytes are extracted. Validation of this robotic system demonstrated acceptable precision and accuracy for three types of liquid transfer, including metering pump ( < 6% RSD and RE for > or = 2.0 mL dispensation), syringe-based laboratory station ( < or = 2.9% RSD and 0.5% RE for volumes between 0.25 and 1.00 mL), and syringe hands ( < 3.5% RSD and RE for volumes between 0.10 and 1.00 mL). For two example compounds, the system provided data which effectively distinguished good solid-phase sorbents from marginal ones through precision, recovery, and chromatographic selectivity. Solid-phase extraction of these compounds from human plasma gave precision (2-10% RSD) and extraction efficiency (96 +/- 6%) comparable to results obtained from manual extractions (92 +/- 11%).
Three different liquid chromatographic methods (two quantitative methods which employ fluorescence detection and one qualitative method which employs selected iondashmonitoring detection) were developed and validated to provide complementary specificity for determination of CI-988, a cholecystokinindashB antagonist, in rat plasma. The first quantitative method involves isocratic separation of “nondashionized” CI-988 and internal standard on a C-18 column, whereas the alternative quantitative method involves isocratic separation of the “anionic” analytes. These two quantitative HPLC methods rely on the intrinsic fluorescence of CI-988 and internal standard for detection, and both methods are equally sensitive (linear range of 2.0–1000 ng ml−1). accurate (±15%, relative error), and precise (⩽15% relative standard deviation). Plasma CI-988 concentrations for samples (N = 69) assayed with the “nondashionized” separation are linearly correlated with concentrations for the same samples assayed with the “anionic” separation (y = 1.08x − 0.57, R = 0.999). In addition, a third qualitative method, HPLC-thermospray mass spectrometry, was developed to provide complementary evaluation of assay specificity through the use of selected CI-988 fragment ion monitoring. When investigating an anomalous chromatographic result that calls into question the specificity of a method, the availability and use of alternative validated chromatographic separations and orthogonal detection schemes are beneficial.
This paper demonstrates the utility of an ion trap mass spectrometer as a detector for trace quantitative determinations of pharmaceuticals in human plasma by capillary gas chromatography/mass spectrometry. A novel acetylcholinesterase inhibitor (CI-1002) was selected as an illustrative example for the technique. When coupled with a selective solid-phase extraction, this approach was capable of quantifying as little as 34 pg (0.50 ng ml(-1), RSD = 12.7%) of compound on the column, and the inter-run precision was typically 3-4% RSD over a 0.5-25 ng ml(-1) linear range. The advantages and requirements of the technique, in addition to the prospects for improvements in the detection limit, are discussed.
A sensitive gradient high-performance liquid chromatographic (HPLC) method for the simultaneous quantitation of a dopamine autoreceptor agonist CI-1007 (I) and its metabolite PD 147693 (II) is described. Monkey plasma samples were purified by liquid-liquid extraction using hexane. Liquid chromatographic separation was achieved on two C18 analytical columns (installed in series) using gradient elution. Column effluent was monitored using a fluorescence detector programmed to change wavelengths at specified times. Minimum quantitation limits of I and II were 3.0 and 5.0 ng/ml, respectively, for a plasma sample volume of 0.100 ml. Linearity was demonstrated up to 300 ng/ml. The assay has been applied to the analysis of I and II in plasma from monkeys following intravenous and oral doses of I.
A sensitive and specific high-performance liquid chromatographic assay for the non-peptide cholecystokinin subtype B receptor antagonist, CI-988, in human and cynomolgus monkey plasma has been developed and validated. The method involves isolation of CI-988 and internal standard by batch robotic solid phase extraction with a C18 cartridge, liquid chromatographic separation on a C18 column and quantitation by fluorescence detection. The human plasma assay is linear from 0.25 to 500 ng/mL for a 1.00-mL plasma aliquot. Assay precision for CI-988 based on human plasma quality control samples was within +/- 7.2% relative standard deviation with an accuracy of +/- 5.6% relative error. The monkey plasma assay is linear from 1.00 to 250 ng/mL for a 0.500-mL plasma aliquot. Assay precision based on monkey plasma quality control samples was within +/- 11.0% relative standard deviation with an accuracy of +/- 2.6% relative error.
A sensitive assay was developed for human epidermal growth factors (hEGF) 1-48 (dosed), hEGF 1-53 (endogenous), without interference from potential metabolites hEGFs 1-47 or 1-46. Spiked human plasma samples were injected directly, utilizing on-line immunoaffinity HPLC (anti-hEGF) clean-up. No change in capacity was noted after 81 cycles. After release from the immunoaffinity column, the fragments were further resolved by strong cation-exchange (SCX) via a column switching valve. Method development also required interfacing immunoaffinity, ion-exchange, and detection components. Immunoassays on collected fractions yielded a detection limit of 1 microgram ml-1, although a detection limit of 75 pg ml-1 appears feasible.