A superconducting self-shielding three-solenoid system with an adjustable shielding factor is developed, implemented, and characterized using a single antiproton in a Penning trap. With the tuned system, we suppress external magnetic field disturbances by up to a factor of 225 +/- 15, allowing antiproton-to-proton charge-to-mass ratio comparisons with fourfold reduced frequency fluctuations and antiproton magnetic moment determinations with tenfold reduced uncertainty.
High-precision comparisons of the proton-to-antiproton charge-to-mass ratios provide sensitive tests of the fundamental charge, parity, time (CPT) invariance. In 2014, we performed such a measurement with a fractional precision of 69parts in a trillion (p.p.t.). In this article, we describe technical developments which were implemented to improve the precision of our previous measurement by at least a factor of 3.
We summarize our recent 1.5 parts per billion measurement of the antiproton magnetic moment using the multi Penning-trap system of the BASE collaboration. The result was achieved by combining the detection of individual spin-transitions of a single antiproton with a novel two-particle spectroscopy technique, which dramatically improved the data sampling rate. This measurement contributes to improve the test of the fundamental charge, parity, time reversal (CPT) invariance in the baryon sector by a factor of 350 compared to our last measurement, and by a factor of 3000 compared to the best competing measurement. We review the measurement technique and discuss the improved limits on CPT-violating physics imposed by this measurement.