The high spatial and temporal variations of airflow patterns in ventilation openings of naturally ventilated animal houses make it difficult to accurately measure the airflow rate:This paper focusses on the development of a fast assessment technique for the airflow rate of a naturally ventilated test facility through the combination of a linear algorithm and local air velocity measurements. This assessment technique was validated against detailed measurement results obtained by the measuring method of Van Overbeke et al. (2015) as a reference.The total air velocity vertical bar(U) over bar vertical bar, the normal vertical bar(Y) over bar vertical bar and tangential velocity component vertical bar(X) over bar vertical bar and the velocity vector vertical bar(U) over bar vertical bar measured at the meteomast were chosen as input variables for the linear algorithms. The airflow rates were split in a group where only uni-directional flows occurred at vent level (no opposite directions of vertical bar(Y) over bar vertical bar present in the airflow pattern of the opening), and a group where bi-directional flows occurred (the air goes simultaneously in and out of the opening). For airflow rates with uni-directional flows the input variables vertical bar(U) over bar vertical bar and vertical bar(Y) over bar vertical bar yielded the most accurate results. For this reason, it was suggested to use the vertical bar(Y) over bar vertical bar instead, of vertical bar(U) over bar vertical bar in ASHRAE's formula of Q = E x A x vertical bar(U) over bar vertical bar.For bi-directional flows a multiple linear model was suggested where input variable vertical bar(U) over bar vertical bar gave the best results to assess the airflow rate. (C) 2016 Elsevier Ltd. All rights reserved.
Ammonia, largely emitted by agriculture, involves a great risk for eutrophication and acidification leading to biodiversity loss. Air scrubbers are widely applied to reduce ammonia emission from pig and poultry housing facilities, but it is not always clear whether their performance meets the requirements. Besides, there is a growing international concern for the livestock related greenhouse gases methane and nitrous oxide but hardly any data concerning their fate in air scrubbers are available. This contribution presents the results from measurement campaigns conducted at a chemical, a biological and a two-stage biological air scrubber installed at pig housing facilities in Flanders. Ammonia, nitrous oxide and methane at the inlet and outlet of the air scrubbers were monitored on-line during one week using a photoacoustic gas monitor, which allowed to investigate diurnal fluctuations in the removal performance of air scrubbers. Additionally, the homogeneity of the air scrubbers, normally checked by gas detection tubes, was investigated in more detail using the continuous data. The biological air scrubber with extra nitrification tank performed well in terms of ammonia removal (86 ± 6%), while the two-stage air scrubber suffered from nitrifying bacteria inhibition. In the chemical air scrubber the pH was not kept constant, lowering the ammonia removal efficiency. A lower ammonia removal efficiency was found during the day, when the ventilation rate was the highest. Nitrous oxide was produced inside the biological and two-stage scrubber, resulting in an increased outlet concentration of more than 200%. Methane could not be removed in the different air scrubbers because of its low water solubility.
Currently there exists no generally accepted reference technique to measure the ventilation rate through naturally ventilated (NV) vents. This has an impact on the reliability of airflow rate control techniques and emission rate measurements in NV animal houses. As an attempt to address this issue a NV test facility was built to develop new airflow rate measurement techniques for both side wall and ridge vents. Three set-ups were used that differed in vent configuration, i.e. one cross ventilated set-up and two ridge ventilated set-ups with different vent sizes.The airflow through the side vents was measured with a technique based on an automatic traverse movement of a 3D ultrasonic anemometer. In the ridge, 7 static 2D ultrasonic anemometers were installed. The methods were validated by applying the air mass conservation principle, i.e. the inflow rates must equal the outflow rates.The calculated in - and outflow rates agreed within (5 +/- 8)%, (8 +/- 5)% and (-9 +/- 7)% for the three different set-ups respectively, over a large range of wind incidence angles. It was found that the side vent configuration was of large importance for the distribution of the airflow rates through the vents. The ridge proved to be a constant outlet, whilst side vents could change from outlet to inlet depending on the wind incidence angle. The range of wind incidence angles in which this transition occurred could be clearly visualized. (C) 2016 Published by Elsevier Ltd.
In order to measure the airflow rate and emission rate of a naturally ventilated livestock building correctly, more reliable measuring techniques need to be developed. A test facility with a cross ventilated room was built at the Institute for Agricultural and Fisheries Research (Belgium) to study a new airflow rate measuring method. This method is based on an automated traverse movement of a 3D ultrasonic anemometer across 2 vents of 0.5m×1.0m. To cope with the fluctuating wind velocity profile, a velocity measurement of 10s in 16 equally distributed measuring points is needed. Moreover, 10 traverse replicates are needed to obtain a representative average flow rate. Based on the law of mass conservation, the accuracy of the method was determined by calculating the relative deviation between the simultaneously measured airflow rates through both vents. A relative error of −1±11% was found, averaged over all wind incidence angles. However, wind angles parallel to the vent resulted in larger relative errors. A 3D velocity measurement in the in- or outlet opening of the test facility is necessary to obtain a correct flow rate. This was especially true in the outlet where up to 30% of the airflow rate was delivered by velocity components other than normal to the vent. The test facility and the developed ventilation rate measuring method can serve as a reference to study and validate new and existing ventilation rate measuring methods.