Since Dec 1988, date of the French-Soviet joint space mission "ARAGATZ", the CIRCE device (Compteur Intégrateur de Rayonnement Complexe dans l'Espace) had recorded dose equivalent and quality factor inside the MIR station (380-410 km, 51.5 degrees). After the initial gas filling two years ago, the low pressure tissue equivalent proportional counter is still in good working conditions. Some results of three periods, viz Dec 1988, Mar-Apr 1989 and Jan-Feb 1990 are presented. The average dose equivalent rates measured are respectively 0.6, 0.8 and 0.6 mSv/day with a quality factor equal to 1.9. Some detailed measurements show the increasing of the dose equivalent rates through the SAA and near polar horns. The real time determination of the quality factors allows to point out high LET (Linear Energy Transfer) events with quality factors in the range 10-20.
During the French-Soviet space mission "Aragatz," the experiment CIRCE (Compteur Integrateur de Rayonnement Complexe dans l'Espace) recorded the dose rate and quality factor values inside the MIR station. This paper presents results obtained with a new active dose equivalent meter based on microdosimetric techniques and using a low pressure tissue equivalent proportional counter. In terms of lineal energy CIRCE device works in the 0.2-1200 keV micrometer-1 range in tissue. Preliminary studies were performed in photon, neutron and heavy ion beams, and in the real stratosphere cosmic radiation field. Long term measurements on-board MIR station from December 1988 to April 1989 gave an average quality factor value equal to 1.9 +/- 0.3. Through the South Atlantic Anomaly (SAA), the quality factor was equal to 1.4. The temporal orbital variations of the dose rates and quality factors have been established in space dosimetry for the first time.
In this paper we present absorbed dose measurements with glass thermoluminescent detectors on external surface of satellites of Kosmos-serie flying in 1983-87. Experiments were performed with thermoluminescent aluminophosphate glasses of thicknesses 0.1, 0.3, 0.4, 0.5, and 1 mm. They were exposed in sets of total thickness between 5 and 20 mm, which were protected against sunlight with thin aluminized foils. In all missions, extremely high absorbed dose values were observed in the first layers of detectors, up to the thickness of 0.2 to 0.5 gcm-2. These experimental results confirm that, during flights at 250 to 400 km, doses on the surface of the satellites are very high, due to the low energy component of the proton and electron radiation.
LET variation with the absorber thickness was measured by plastic detectors exposed on COSMOS-1129 satellite.