While blood-contacting materials are widely deployed in medicine in vascular stents, catheters, and cannulas, devices fail in situ because of thrombosis and restenosis. Furthermore, microbial attachment and biofilm formation is not an uncommon problem for medical devices. Even incremental improvements in hemocompatible materials can provide significant benefits for patients in terms of safety and patency as well as substantial cost savings. Herein, a novel but simple strategy is described for coating a range of medical materials, that can be applied to objects of complex geometry, involving plasma-grafting of an ultrathin hyperbranched polyglycerol coating (HPG). Plasma activation creates highly reactive surface oxygen moieties that readily react with glycidol. Irrespective of the substrate, coatings are uniform and pinhole free, comprising O─C─O repeats, with HPG chains packing in a fashion that holds reversibly binding proteins at the coating surface. In vitro assays with planar test samples show that HPG prevents platelet adhesion and activation, as well as reducing (>3 log) bacterial attachment and preventing biofilm formation. Ex vivo and preclinical studies show that HPG-coated nitinol stents do not elicit thrombosis or restenosis, nor complement or neutrophil activation. Subcutaneous implantation of HPG coated disks under the skin of mice shows no evidence of toxicity nor inflammation.
Whilst blood‐contacting materials are widely deployed in medicine in vascular stents, catheters and cannulas, devices fail in‐situ because of thrombosis and restenosis. Furthermore, microbial attachment and biofilm formation is not an uncommon problem for medical devices. Even incremental improvements in hemocompatible materials could provide significant benefits for patients in terms of safety and patency as well as substantial cost savings.Herein, we describe a novel but simple strategy for coating a range of medical materials, that can be applied to objects of complex geometry, involving plasma‐grafting of an ultra‐thin hyperbranched polyglycerol coating (HPG). Plasma activation creates highly reactive surface oxygen moieties that readily react with glycidol. Irrespective of the substrate, coatings are uniform and pinhole free, comprising O‐C‐O repeats, with HPG chains packing in a fashion that holds reversibly binding proteins at the coating surface.In vitro assays with planar test samples show that HPG prevents platelet adhesion and activation, as well as reducing (>3log) bacterial attachment and preventing biofilm formation. Ex vivo and preclinical studies show that HPG‐coated nitinol stents do not elicit thrombosis or restenosis, nor complement or neutrophil activation. Subcutaneous implantation of HPG coated disks under the skin of mice showed no evidence of toxicity nor inflammation. This article is protected by copyright. All rights reserved
The progression of cancer is facilitated by infiltrating leukocytes which can either actively kill cancer cells or promote their survival. Our current understanding of leukocyte recruitment into tumors is largely limited to the adhesion molecules and chemokines expressed by conventional blood vessels that are lined by endothelial cells (ECs). However, cancer cells themselves can form their own vascular structures (a process known as vasculogenic mimicry (VM)); but whether they actively participate in the recruitment of leukocytes remains to be elucidated. Herein, we demonstrate that VM-competent human melanoma cell lines express multiple adhesion molecules (e.g. CD44, intercellular adhesion molecule (ICAM)-1 and junction adhesion molecules (JAMs)) and chemokines (e.g. CXCL8 and CXCL12) relevant for leukocyte recruitment. Microfluidic-based adhesion assays revealed that similar to ECs, VM-competent melanoma cells facilitate the rolling and adhesion of leukocytes, particularly monocytes, under conditions of shear flow. Moreover, we identified ICAM-1 to be a key participant in this process. Transwell assays showed that, similar to ECs, VM-competent melanoma cells facilitate monocyte transmigration toward a chemotactic gradient. Gene expression profiling of human melanoma patient samples confirmed the expression of numerous leukocyte capture adhesion molecules and chemokines. Finally, immunostaining of patient tissue microarrays revealed that tumors with high VM content also contained higher numbers of leukocytes (including macrophages). Taken together, this study suggests an underappreciated role of VM vessels in solid tumors via their active participation in leukocyte recruitment and begins to identify key adhesion molecules and chemokines that underpin this process.
Cardiovascular disease is a leading cause of death worldwide; however, despite substantial advances in medical device surface modifications, no synthetic coatings have so far matched the native endothelium as the optimal hemocompatible surface for blood-contacting implants. A promising strategy for rapid restoration of the endothelium on blood-contacting biomedical devices entails attracting circulating endothelial cells or their progenitors, via immobilized cell-capture molecules; for example, anti-CD34 antibody to attract CD34+ endothelial colony-forming cells (ECFCs). Inherent is the assumption that the cells attracted to the biomaterial surface are bound exclusively via a specific CD34 binding. However, serum proteins might adsorb in-between or on the top of antibody molecules and attract ECFCs via other binding mechanisms. Here, we studied whether a surface with immobilized anti-CD34 antibodies attracts ECFCs via a specific CD34 binding or a nonspecific (non-CD34) binding. To minimize serum protein adsorption, a fouling-resistant layer of hyperbranched polyglycerol (HPG) was used as a "blank slate," onto which anti-CD34 antibodies were immobilized via aldehyde-amine coupling reaction after oxidation of terminal diols to aldehydes. An isotype antibody, mIgG1, was surface-immobilized analogously and was used as the control for antigen-binding specificity. Cell binding was also measured on the HPG hydrogel layer before and after oxidation. The surface analysis methods, x-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectrometry, were used to verify the intended surface chemistries and revealed that the surface coverage of antibodies was sparse, yet the anti-CD34 antibody grafted surface-bound ECFCs very effectively. Moreover, it still captured the ECFCs after BSA passivation. However, cells also attached to oxidized HPG and immobilized mIgG1, though in much lower amounts. While our results confirm the effectiveness of attracting ECFCs via surface-bound anti-CD34 antibodies, our observation of a nonspecific binding component highlights the importance of considering its consequences in future studies.
Abstract Synthetic materials with an innate ability to avoid the foreign-body-response remain an unrealized goal that would transform the medical device industry. The balance of bulk material properties, that enable a device to perform as intended, with surface properties, that provide bio- and hemocompatibility, has always required the former to be prioritized. While all materials used in modern devices have an acceptable level of biocompatibility, imperfection remains, ultimately leading to device failure, or requiring pharmacological intervention for it to be tolerated. Where such devices cause damage or place strain on the normal architecture of the surrounding tissue, these impacts may initiate inflammatory responses that can also led to failure. This is most evident in the treatment of vessels in the lower extremity in patients with peripheral arterial disease (PAD), where in-stent restenosis (ISR) remains a significant challenge for vascular surgeons. Blood-contacting devices, such as stents and artificial grafts, are considered particularly difficult to shield from the foreign-body-response due to the immediate and direct exposure to blood and therefore, the full gamut of the body’s immune responses. Pharmacological treatment is currently paramount to successful percutaneous vascular intervention (PVI) with antiplatelet therapies being prescribed to manage the risk of thrombosis and cytotoxic drug-eluting coatings to reduce restenosis. Here, we present data that indicate a nano-thin coating of hyperbranched polyglycerol (HPG) can greatly improve the safety and durability of endovascular metal stents. The HPG coating successfully prevents the binding and activation of platelets and greatly reduces the thrombogenicity of nitinol stents when studied ex vivo, using fresh human blood. In vivo, HPG-coated stainless-steel stents remained patent after 28 days in apolipoprotein E (ApoE) knockout mice while control stents all became completely occluded, highlighting the HPG coating’s ability to reduce restenosis. Together, these properties could help alleviate the industry’s dependence on blood-thinning and antiproliferative drugs to resolve device compatibility issues; thereby greatly improve patients’ quality of life through faster recovery, fewer complications and fewer repeat interventions. Furthermore, this coating technology is compatible with a range of materials commonly used in the production of implantable medical devices, such as stainless steel, nitinol, silicone, and polytetrafluoroethylene, while being highly scalable, cost effective and stable. Taken together, HPG presents itself as an alternative coating suitable for a broad range of vascular devices including stents and grafts.
Hyperbranched polyglycerol (HPG) was previously investigated as a nonfouling hydrophilic grafted layer on biomaterial surfaces, analogous to the well-known poly(ethylene oxide) (PEO), but the range of adsorbing cells and proteins tested was limited and at times the assays used were not the most sensitive. Thus, the questions arise whether HPG-grafted layers can indeed efficiently resist adsorption of a wider range of adsorbing biological entities, and how would different biological entities interact with such a coating. An HPG coating of 25 nm thickness was grafted onto a spin-coated and plasma-treated polystyrene (PS) layer on a silicon wafer substrate; this provided a well-suited system for surface analyses by X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (ToF-SIMS), and atomic force microscopy (AFM), which verified the presence of a uniform, smooth grafted HPG layer. Adsorption of bovine serum albumin, lysozyme, fibrinogen, and endothelial cell growth medium 2 (EGM2) was reduced by >90%, with the adsorbed amounts close to the detection limit of XPS but still detectable by ToF-SIMS using principal component analysis. With human serum, however, the reduction in adsorption was slightly less pronounced. Smooth muscle cells (SMCs) and fibroblasts were virtually unable to attach onto the grafted HPG layer, with >99% reductions at 6 h compared with plasma-treated PS; the few attached cells remaining rounded and unable to spread. Their attachment might have resulted from coating defects. Testing with full blood showed that unlike for the control surface (plasma-treated PS), platelets did not adhere to the HPG surface, but there was attachment of some cells that stained CD11b positive and likely are neutrophils. Cells of the fungal organism Candida albicans were also able to attach onto the HPG surface to a limited extent, but in contrast to the control surface, the attached cells on HPG did not form hyphal extensions and thus seem to be compromised in their ability to invade and to form biofilms. Our data suggest that "low-fouling" is a better term than nonfouling for a grafted HPG layer as the resistance to adsorption is not uniform across a range of proteins and cells. It is also important in future work to study whether the cells that do attach can still exert their normal functions; our observation of the absence of hyphal extensions for C. albicans suggests that this may not be so. Hence, the potential utility of a grafted HPG layer may be not just a function of adsorbed amounts but also of the functionality of adsorbed proteins and cells.
Cardiovascular disease (CVD) is the leading cause of death worldwide, accounting for 31% of all deaths in 2012. In coronary artery disease, the CVD of highest prevalence, reduced blood flow arises due to plaque formation on the arterial wall, eventually resulting in complete blockage of the blood vessel. To restore blood flow, a small mesh tube called a stent is deployed into the occluded artery. Metal alloys are currently preferred for stent fabrication. However, these bare metal stents (BMS) are well documented to trigger a number of adverse reactions, such as thrombosis (clot formation) and in-stent restenosis (re-narrowing of the artery).
This study outlines the synthetic and purification process used to obtain hyperbranched polyglycerol (HPG) within a molecular weight range not previously obtainable. Purified fractions with low polydispersity are achieved via successive precipitations from acetone. Furthermore, the use of the initiator molecule 5-hexyne-1-ol introduces alkyne functionality at the core of each HPG molecule. Alkyne-azide cycloaddition chemistry in combination with NMR and field flow fractionation analysis is used to verify the availability of the alkyne core for bioconjugation across the range of molecular weights.
We demonstrate microwave-induced heating of gold nanoparticles and nanorods. An appreciably higher and concentration-dependent microwave-induced heating rate was observed with aqueous dispersions of the nanomaterials as opposed to pure water and other controls. Grafted with the thermoresponsive polymer poly(N-isopropylacrylamide), these gold nanomaterials react to microwave-induced heating with a conformational change in the polymer shell, leading to particle aggregation. We subsequently covalently immobilize concanavalin A (Con A) on the thermoresponsive gold nanoparticles. Con A is a bioreceptor commonly used in bacterial sensors because of its affinity for carbohydrates on bacterial cell surfaces. The microwave-induced thermal transitions of the polymer reversibly switch on and off the display of Con A on the particle surface and hence the interactions of the nanomaterials with carbohydrate-functionalized surfaces. This effect was determined using linear sweep voltammetry on a methyl-α-d-mannopyranoside-functionalized electrode.
AIM:This study aimed to demonstrate radiofrequency (RF)-triggered release of drugs and drug carriers from drug-eluting implants using gold nanoparticles as energy transducers.MATERIALS & METHODS:Titanium wire with a titania nanotube layer was used as an implant loaded with indomethacin and micelles (tocopheryl PEG succinate) as a drug and drug carrier model. RF signals were generated from a customized RF generator to trigger in vitro release.RESULTS & DISCUSSION:Within 2.5 h, 18 mg (92%) of loaded drug and 14 mg (68%) of loaded drug carriers were released using short RF exposure (5 min), compared with 5 mg (31%) of drug and 2 mg (11%) of drug carriers without a RF trigger. Gold nanoparticles can effectively function as RF energy transducers inside titania nanotubes for rapid release of therapeutics at arbitrary times.CONCLUSION:The results of this study show that RF is a promising strategy for triggered release from implantable drug delivery systems where on-demand delivery of therapeutics is required.
We demonstrate the patterned biofunctionalization of antifouling hyperbranched polyglycerol (HPG) coatings on silicon and glass substrates. The ultralow fouling HPG coatings afforded straightforward chemical handles for rapid bioconjugation of amine containing biomolecular species. This was achieved by sodium periodate oxidation of terminal HPG diols to yield reactive aldehyde groups. Patterned microprinting of sodium periodate and cell adhesion mediating cyclic peptides containing the RGD sequence resulted in an array of covalently immobilized bioactive signals. When incubated with mouse fibroblasts, the HPG background resisted cell attachment whereas high density cell attachment was observed on the peptide spots, resulting in high-contrast cell microarrays. We also demonstrated single-step, in situ functionalization of the HPG coatings by printing periodate and peptide concurrently. Our results demonstrate the effectiveness of antifouling and functionalized HPG graft polymer coatings and establish their use in microarray applications for the first time.
Anionic ring-opening polymerization of glycidol was initiated from activated glass, silicon, and porous silicon substrates to yield thin, ultralow-fouling hyperbranched polyglycerol (HPG) graft polymer coatings. Substrates were activated by deprotonation of surface-bound silanol functionalities. HPG polymerization was initiated upon the addition of freshly distilled glycidol to yield films in the nanometer thickness range. X-ray photoelectron spectroscopy, contact angle measurements, and ellipsometry were used to characterize the resulting coatings. The antifouling properties of HPG-coated surfaces were evaluated in terms of protein adsorption and the attachment of mammalian cells. The adsorption of bovine serum albumin and collagen type I was found to be reduced by as much as 97 and 91%, respectively, in comparison to untreated surfaces. Human glioblastoma and mouse fibroblast attachment was reduced by 99 and 98%, respectively. HPG-grafted substrates outperformed polyethylene glycol (PEG) grafted substrates of comparable thickness under the same incubation conditions. Our results demonstrate the effectiveness of antifouling HPG graft polymer coatings on a selected range of substrate materials and open the door for their use in biomedical applications.
The control over biointerfacial interactions is the key to a broad range of biomedical applications, ranging from implantable devices to drug delivery and nanomedicine. In many of these applications, coatings are required that reduce or prevent non-specific interactions with the biological environment, while at the same time presenting specific bioactive signals. Whilst surface coatings based on polymers such as poly(ethylene glycol) (PEG) have been used successfully, many limitations persist in regard to the biocompatibility, stability and functionality of state-of-the-art polymer coatings. Most of these limitations are related to the fact that, typically, linear polymers are used with associated limited chemical functionality. Here, we examine the development of hyperbranched polyglycerols (HPGs) as promising candidates for the replacement of traditional linear polymers, such as the chemically analogous PEG, for the control of biointerfacial interactions. HPGs are highly branched globular molecules that exhibit a high valency, allow easy access to a variety of functionalities and can present biologically active signals. In this review, a comprehensive overview is provided with respect to the history, synthetic strategies, modifications and applications of HPGs.
Here, we demonstrate a straightforward click-chemistry-based approach for the functionalisation of single walled carbon nanotubes with oligo-lysine dendrons. Azide-functionalised nanotubes were reacted with alkyne-focal dendrons using the 1,3 dipolar Cu-catalysed azide alkyne cycloaddition reaction. Peptide dendron functionalised nanotubes showed significantly increased biocompatibility in rat mesenchymal stem cell culture.
We describe the preparation of biodegradable porous silicon nanoparticles (pSiNP) functionalized with cancer cell targeting antibodies and loaded with the hydrophobic anti-cancer drug camptothecin. Orientated immobilization of the antibody on the pSiNP is achieved using novel semicarbazide based bioconjugate chemistry. To demonstrate the generality of this targeting approach, the three antibodies MLR2, mAb528 and Rituximab are used, which target neuroblastoma, glioblastoma and B lymphoma cells, respectively. Successful targeting is demonstrated by means of flow cytometry and immunocytochemistry both with cell lines and primary cells. Cell viability assays after incubation with pSiNPs show selective killing of cells expressing the receptor corresponding to the antibody attached on the pSiNP.
Here, we investigate the catalytic activity of various copper (Cu)-loaded poly(amido amine) (PAMAM) dendrimers towards the Cu(I)-catalysed azide–alkyne cycloaddition (CuAAC). Reactivity is tested on a model reaction between azido propanol and propargyl alcohol in aqueous solution. We observe significantly faster conversion using PAMAM dendrimers as macromolecular Cu(I) ligands compared to traditional small molecular ligand systems, and demonstrate that the macromolecular catalyst can be removed by ultrafiltration.
A continuous Flow Reactor (CFR) process based on the hydrogen reduction of the bromosilanes SiBr4 and SiHBr3 was proposed. Initial experiments carried and directed at obtaining overall yield data for bromosilane reduction in the CFR, indicated the need for increased reactor residence time and deposition substrate particle packing density to fully characterize the kinetics (rate) and thermodynamics (yield) of observed silicon production. Fluidized bed experiments were therefore initiated to overcome these experimental difficulties, which showed both thermal decomposition and hydrogen reduction of SiHBr3 in a fluid bed reactor to present attractive closed-loop processes for producing solar cell grade polycrystalline silicon. No process selection could be made however due to the fact that preliminary optimization of 2 of 3 process stages in each case during the course of the experimental program showed comparable attainment of cost element objectives.