The Coupled Dark State Magnetometer (CDSM) is an optically pumped magnetometer. For the Jupiter Icy Moons Explorer mission, the CDSM and two fluxgate magnetometers are combined in the J-MAG instrument to measure the static and low frequency magnetic field in the Jupiter system. During certain calibration manoeuvres, the CDSM has to be able to measure magnetic field strengths down to 100 nT with an accuracy of 0.2 nT ( 1 sigma). At such low magnetic fields, the CDSM's operational parameters must be carefully selected to obtain narrow resonance structures. Otherwise, the coupled dark state resonances, used for the magnetic field detection in different instrument modes, overlap and result in a systematic error. The overlap of the resonances and therefore the systematic error mainly depends on the resonance line width and the selected modulation frequencies for the detection of the resonances. We show that a line width of less than 200 Hz and selecting a modulation frequency of about the resonance line width are beneficial at magnetic field strengths B<1.5 mu T. In this paper we demonstrate that with the found instrument settings the CDSM is able to measure magnetic field strengths below 100 nT with a systematic error less than 0.2 nT resulting from the overlap of the resonances.
This paper discusses the accuracy of the scalar Coupled Dark State Magnetometer on board the Jupiter Icy Moons Explorer (JUICE) mission of the European Space Agency (ESA). The scalar magnetometer, referred to as MAGSCA, is part of the J-MAG instrument. MAGSCA is an optical omnidirectional scalar magnetometer based on coherent population trapping, a quantum interference effect, within the hyperfine manifold of the 87Rb D1 line. The measurement principle is only based on natural constants; therefore, it is in principle drift-free, and no calibration is required. However, the technical realisation can influence the measurement accuracy. The most dominating effects are heading characteristics, which are deviations of the magnetic field strength measurements from the ambient magnetic field strength. These deviations are a function of the angle between the sensor axis and the magnetic field vector and are an intrinsic physical property of the measurement principle of the magnetometer. The verification of the accuracy of the instrument is required to ensure its compliance with the performance requirement of 0.2 nT (1σ) with a data rate of 1 Hz. The verification is carried out with four dedicated sensor orientations in a Merritt coil system, which is located in the geomagnetic Conrad Observatory (COBS). The coil system is used to compensate the Earth's magnetic field and to apply appropriate test fields to the sensor. This paper presents a novel method to separate the heading characteristics of the instrument from residual (offset) fields within the coil system by fitting a mathematical model to the measured data and by the successful verification of the MAGSCA performance requirement.
This paper discusses various frequency modulation and intensity modulation capabilities within a sample of direct laser current modulated identical vertical cavity surface emitting laser diodes. The presented analysis is based on measurements of the spectral amplitudes as a function of the applied modulation power at a constant modulation frequency of 3.517 GHz. Their evaluation by Bessel function fits produces the three modulation parameters: frequency modulation index, intensity modulation index (via the α parameter) and the side band asymmetry of the first order side bands. The variation of the laser diode’s modulation capability is discussed. It is found that the individual laser diodes show a large variation in their modulation capabilities. This requires the selection of suitable laser diodes as a laser source for atomic vapour applications with the special emphasis on a coherent population trapping based scalar magnetometers
The Coupled Dark State Magnetometer is an atomic magnetometer designed for magnetic field measurements in space. Its measurement principle is based on the excitation of coupled dark state resonances prepared via the coherent population trapping effect. The coupled dark state resonances enable the compensation of disturbing frequency shifts which degrade the measurement accuracy. Results with a sensor design based on a single laser beam pass through the sensor unit reveal a reduced ability to compensate these disturbing effects compared to theoretical predictions. Therefore, a new sensor design is presented which enables a dual laser beam pass through the sensor unit. For almost all angles between the external magnetic field and the light propagation direction, the dual pass sensor design enables a better compensation of disturbing frequency shifts than the single pass sensor design - up to a factor of nine.
A set of optical fiber assemblies has been developed and successfully qualified for its use on a European space science mission to the icy moons of Jupiter (Jupiter Icy Moons Explorer, JUICE), to be launched in 2022. The paper gives an overview of the design challenges, the test methods used for failure detection and screening of the optical fiber cable assemblies as well as the further testing performed in the frame of a lot acceptance qualification.
With a new type of a scalar magnetometer, the Coupled Dark State Magnetometer (CDSM) aboard the China Seismo-Electromagnetic Satellite (CSES) mission, we observed magnetic field fluctuations in the period mid July 2018 until mid November 2018. The measurement range of the CDSM is from 1000 nT up to 100000 nT and the accuracy 0.19 nT (1), the operational performance is discussed in (2). We are using 1 Hz data in the latitude range -65 degree to +65 degree, CSES has an altitude of approx. 507 km in Sun synchronous polar configuration with 97.4 degree inclination. We analyzed the total magnetic field turbulence by converting the time series into thermodynamic parameters, e.g. entropy, finally these results have been compared with ground based seismic and volcanic events. Ref: (1) Pollinger, A., et al.: Coupled dark state magnetometer for the China Seismo-Electromagnetic Satellite, Measurement Science and Technology, 29, 9, 2018. https://doi.org/10.1088/1361-6501/aacde4 (2) Pollinger, A., et al.: In-orbit results of the Coupled Dark State Magnetometer aboard the China Seismo-Electromagnetic Satellite, Geosci. Instrum. Method. Data Syst., 9, 275–291, 2020. https://doi.org/10.5194/gi-9-275-2020
The China Seismo-Electromagnetic Satellite (CSES) was launched in February 2018 into a polar, sun-synchronous, low Earth orbit. It provides the first demonstration of the Coupled Dark State Magnetometer (CDSM) measurement principle in space. The CDSM is an optical scalar magnetometer based on the coherent population trapping (CPT) effect and measures the scalar field with the lowest absolute error aboard CSES. Therefore, it serves as the reference instrument for the measurements done by the fluxgate sensors within the High Precision Magnetometer instrument package. In this paper several correction steps are discussed in order to improve the accuracy of the CDSM data. This includes the extraction of valid 1 Hz data, the application of the sensor heading characteristic, the handling of discontinuities, which occur when switching between the CPT resonance superpositions, and the removal of fluxgate and satellite interferences. The in-orbit performance is compared to the Absolute Scalar Magnetometer aboard the Swarm satellite Bravo via the CHAOS magnetic field model. Additionally, an uncertainty of the magnetic field measurement is derived from unexpected parametric changes of the CDSM in orbit in combination with performance measurements on the ground.
In this study we investigate volcanic eruption phenomena related to ionospheric disturbances, e.g. Heki (2006) used total electron content (TEC) measurements for this task. In particular, a model is developed how discharge phenomena (e.g. Houghton etal, 2013) can produce magnetic field variations at SWARM and CSES satellite orbits, i.e. altitudes of ~500 km in the F-region. Several coupling mechanism between lithosphere, atmosphere, and ionosphere are discussed by Simões etal (2012).Experimental evidence is based on magnetic field observations aboard CSES mission in the time frame July 2018 to January 2019. The theoretical considerations include the source mechanism, propagation path, and the signal strength at low earth orbit satellite altitude.Ref:(1) Heki, K., Explosion energy of the 2004 eruption of the Asama Volcano, central Japan, inferred from ionospheric disturbances, GRL, 33, L14303, 2006. doi:10.1029/2006GL026249(2) Houghton, I. M. P., K. L. Aplin, and K. A. Nicoll, Triboelectric Charging of Volcanic Ash from the 2011 Grı́msvötn Eruption, PRL, 111, 118501, 2013. doi:10.1103/PhysRevLett.111.118501 arXiv:1304.1784(3) Simões F., R. Pfaff, J.-J. Berthelier, J. Klenzing, A Review of Low Frequency Electromagnetic Wave Phenomena Related to Tropospheric-Ionospheric Coupling Mechanisms, SSR, 168:551–593, 2012. doi:10.1007/s11214-011-9854-0
The High Precision Magnetometer (HPM) is one of the main payloads onboard the China Seismo-Electromagnetic Satellite (CSES). The HPM consists of two Fluxgate Magnetometers (FGM) and the Coupled Dark State Magnetometer (CDSM), and measures the magnetic field from DC to 15 Hz. The FGMs measure the vector components of the magnetic field; while the CDSM detects the magnitude of the magnetic field with higher accuracy, which can be used to calibrate the linear parameters of the FGM. In this paper, brief descriptions of measurement principles and performances of the HPM, ground, and in-orbit calibration results of the FGMs are presented, including the thermal drift and magnetic interferences from the satellite. The HPM in-orbit vector data calibration includes two steps: sensor non-linearity corrections based on on-ground calibration and fluxgate linear parameter calibration based on the CDSM measurements. The calibration results show a reasonably good stability of the linear parameters over time. The difference between the field magnitude calculated from the calibrated FGM components and the magnitude directly measured by the CDSM is just 0.5 nT (1 σ ) when the linear parameters are fitted separately for the day- and the night-side. Satellite disturbances have been analyzed including soft and hard remanence as well as magnetization of the magnetic torquer, radiation from the Tri-Band Beacon, and interferences from the rotation of the solar wing. A comparison shows consistency between the HPM and SWARM magnetic field data. Observation examples are introduced in the paper, which show that HPM data can be used to survey the global geomagnetic field and monitor the magnetic field disturbances in the ionosphere.
We performed an endurance test with single-mode vertical-cavity surface-emitting lasers (VCSEL) under vacuum condition and increased operational parameters (laser current and laser temperature) to accelerate the aging of the lasers. During the endurance test the emitted polarization-dependent and polarization-independent optical light power from the lasers was detected. Additionally, electro-optical characterisations including measurements of the combination of laser current and laser temperature to excite the 87 Rb D 1 transition ( λ = 795 nm), the current and temperature tuning coefficients, laser line width, threshold current and the polarization ellipse were performed for the aged lasers. The test was started with a number of 12 VCSELs consisting of 4 lasers each from 3 different suppliers. The aging behaviour of VCSELs was investigated with respect to the development of a new optical magnetometer prototype for space missions with a mission duration of up to 17 years. Only a limited change of the electro-optical parameters can be tolerated by the instrument design over the mission duration. The endurance test and the electro-optical characterizations revealed clear differences in the aging behaviour of the three suppliers. Lasers from one supplier showed that they can be operated for more than 17 years under vacuum conditions without major degradation of their operational parameters.
With spaceborne magnetic field measurements it is possible to investigate the interior of planets,moons and asteroids which have either an intrinsic or a crustal magnetic field. Furthermore, preciseknowledge of the magnetic field is essential to derive fundamental information about theenvironment surrounding different bodies in the solar system as well as to explore the interplanetaryspace. [...]
The coupled dark state magnetometer (CDSM) is an optically pumped scalar magnetometer, which is based on two-photon spectroscopy of free alkali atoms. This paper introduces the measurement principle, instrument design, required resources and key performance characteristics of the flight model for the China Seismo-Electromagnetic Satellite, which is the first demonstration of the CDSM measurement principle in space. The CDSM uses several coherent population trapping (CPT) resonances in parallel in order to reduce systematic errors, e.g. the sensor temperature dependence. Overall five control loops were identified to enable a reliable operation. As known so far CPT is the only effect in optical magnetometry which inherently enables omni-directional, dead-zone-free measurements. This leads to a simple all-optical sensor design without double cell units, excitation coils or electromechanical parts. The instrument is characterized by an accuracy of 0.19 nT (sigma), a detection noise of 50 pTrms at 1 s integration time, a mass of 1672 g and an in-Earth orbit measured power consumption of 3394 mW.
The High Precision Magnetometer (HPM) is one of the main payloads for the China Seismo-Electromagnetic Satellite (CSES) mission. Its task is to detect the vector information of the magnetic field from DC to 15Hz. Consistent with the mission schedule, the HPM Engineering Model (EM) development has been finished and evaluated. This article introduces test results and performance parameters. The linearity, noise, stability and temperature drifts of the two fluxgate sensors were tested in China while the Coupled Dark State Magnetometer (CDSM) scalar sensor was evaluated for the linearity and the long term stability in both, Austria and China. The HPM EM meets the performance requirements defined for the CSES mission.