Intracorporeal needle-based therapeutic ultrasound (NBTU) is a minimally invasive option for intervening in malignant brain tumors, commonly used in thermal ablation procedures. This technique is suitable for both primary and metastatic cancers, utilizing a high-frequency alternating electric field (up to 10 MHz) to excite a piezoelectric transducer. The resulting rapid deformation of the transducer produces an acoustic wave that propagates through tissue, leading to localized high-temperature heating at the target tumor site and inducing rapid cell death. To optimize the design of NBTU transducers for thermal dose delivery during treatment, numerical modeling of the acoustic pressure field generated by the deforming piezoelectric transducer is frequently employed. The bioheat transfer process generated by the input pressure field is used to track the thermal propagation of the applicator over time. Magnetic resonance thermal imaging (MRTI) can be used to experimentally validate these models. Validation results using MRTI demonstrated the feasibility of this model, showing a consistent thermal propagation pattern. However, a thermal damage isodose map is more advantageous for evaluating therapeutic efficacy. To achieve a more accurate simulation based on the actual brain tissue environment, a new finite element method (FEM) simulation with enhanced damage evaluation capabilities was conducted. The results showed that the highest temperature and ablated volume differed between experimental and simulation results by 2.1884°C (3.71%) and 0.0631 cm3 (5.74%), respectively. The lowest Pearson correlation coefficient (PCC) for peak temperature was 0.7117, and the lowest Dice coefficient for the ablated area was 0.7021, indicating a good agreement in accuracy between simulation and experiment.
An ultra-high diffusion b-value protocol ( b =7,000-30,000s/mm 2 ) was acquired in a high-performance 3.0 T MAGNUS head gradient system (max gradient amplitude=200 mT/m and max slew rate=500 T/m/s) for white matter microstructure imaging.With shorter TE enabled by MAGNUS, measurements of intra-axonal diffusivities are demonstrated at ultra-high b-values. At these ultra-high b-values, signal from extra-axonal water is effectively suppressed but SNR is also reduced. We show that real-valued image reconstruction maintains Gaussian noise properties and reduces Rician bias, allowing better quantification of intra-axonal diffusivities and effective axonal radii in healthy volunteers and in ongoing human subject research studies of mild traumatic brain injury.
PURPOSE:To demonstrate the technical feasibility and the value of ultrahigh-performance gradient in imaging the prostate in a 3T MRI system. METHODS:In this local institutional review board-approved study, prostate MRI was performed on 4 healthy men. Each subject was scanned in a prototype 3T MRI system with a 42-cm inner-diameter gradient coil that achieves a maximum gradient amplitude of 200 mT/m and slew rate of 500 T/m/s. PI-RADS V2.1-compliant axial T2 -weighted anatomical imaging and single-shot echo planar DWI at standard gradient of 70 mT/m and 150 T/m/s were obtained, followed by DWI at maximum performance (i.e., 200 mT/m and 500 T/m/s). In comparison to state-of-the-art clinical whole-body MRI systems, the high slew rate improved echo spacing from 1020 to 596 μs and, together with a high gradient amplitude for diffusion encoding, TE was reduced from 55 to 36 ms. RESULTS:In all 4 subjects (waist circumference = 81-91 cm, age = 45-65 years), no peripheral nerve stimulation sensation was reported during DWI. Reduced image distortion in the posterior peripheral zone prostate gland and higher signal intensity, such as in the surrounding muscle of high-gradient DWI, were noted. CONCLUSION:Human prostate MRI at simultaneously high gradient amplitude of 200 mT/m and slew rate of 500 T/m/s is feasible, demonstrating that improved gradient performance can address image distortion and T2 decay-induced SNR issues for in vivo prostate imaging.
Measuring the time/frequency dependence of diffusion MRI is a promising approach to distinguish between the effects of different tissue microenvironments, such as membrane restriction, tissue heterogeneity, and compartmental water exchange. In this study, we measure the frequency dependence of diffusivity (D) and kurtosis (K) with oscillating gradient diffusion encoding waveforms and a diffusion kurtosis imaging (DKI) model in human brains using a high-performance, head-only MAGNUS gradient system, with a combination of b-values, oscillating frequencies (f), and echo time that has not been achieved in human studies before. Frequency dependence of diffusivity and kurtosis are observed in both global and local white matter (WM) and gray matter (GM) regions and characterized with a power-law model ∼Λ*fθ. The frequency dependences of diffusivity and kurtosis (including changes between fmin and fmax, Λ, and θ) vary over different WM and GM regions, indicating potential microstructural differences between regions. A trend of decreasing kurtosis over frequency in the short-time limit is successfully captured for in vivo human brains. The effects of gradient nonlinearity (GNL) on frequency-dependent diffusivity and kurtosis measurements are investigated and corrected. Our results show that the GNL has prominent scaling effects on the measured diffusivity values (3.5∼5.5% difference in the global WM and 6∼8% difference in the global cortex) and subsequently affects the corresponding power-law parameters (Λ, θ) while having a marginal influence on the measured kurtosis values (<0.05% difference) and power-law parameters (Λ, θ). This study expands previous OGSE studies and further demonstrates the translatability of frequency-dependent diffusivity and kurtosis measurements to human brains, which may provide new opportunities to probe human brain microstructure in health and disease.
Background In stereotactic radiosurgery, isodose lines must be considered to determine how surrounding tissue is affected. In thermal ablative therapy, such as laser interstitial thermal therapy (LITT), transcranial MR-guided focused ultrasound (tcMRgFUS), and needle-based therapeutic ultrasound (NBTU), how the surrounding area is affected has not been well studied.Objective We aimed to quantify the transition zone surrounding the ablation core created by magnetic resonance-guided robotically-assisted (MRgRA) delivery of NBTU using multi-slice volumetric 2-D magnetic resonance thermal imaging (MRTI) and subsequent characterization of the resultant tissue damage using histopathologic analysis.Methods Four swine underwent MRgRA NBTU using varying duration and wattage for treatment delivery. Serial MRI images were obtained, and the most representative were overlaid with isodose lines and compared to brain tissue acquired postmortem which underwent histopathologic analysis. These results were also compared to predicted volumes using a finite element analysis model. Contralateral brain tissue was used for control data.Results Intraoperative MRTI thermal isodose contours were characterized and comprehensively mapped to post-operative MRI images and qualitatively compared with histological tissue sections postmortem. NBTU 360° ablations induced smaller lesion volumes (33.19 mm3; 120 s, 3 W; 30.05 mm3, 180 s, 4 W) versus 180° ablations (77.20 mm3, 120 s, 3 W; 109.29 mm3; 180 s; 4 W). MRTI/MRI overlay demonstrated the lesion within the proximal isodose lines. The ablation-zone was characterized by dense macrophage infiltration and glial/neuronal loss as demonstrated by glial fibrillary acidic protein (GFAP) and neurofilament (NF) absence and avid CD163 staining. The transition-zone between lesion and normal brain demonstrated decreased macrophage infiltration and measured ∼345 microns (n − 3). We did not detect overt hemorrhages or signs of edema in the adjacent spared tissue.Conclusion We successfully performed MRgRA NBTU ablation in swine and demonstrated minimal histologic changes extended past the ablation-zone. The lesion was characterized by macrophage infiltration and glial/neuronal loss which decreased through the transition-zone.
Abstract Background High-intensity focused ultrasound (HIFU) serves as a noninvasive stereotactic system for the ablation of brain metastases; however, treatments are limited to simple geometries and energy delivery is limited by the high acoustic attenuation of the calvarium. Minimally-invasive magnetic resonance-guided robotically-assisted (MRgRA) needle-based therapeutic ultrasound (NBTU) using multislice volumetric 2-D magnetic resonance thermal imaging (MRTI) overcomes these limitations and has potential to produce less collateral tissue damage than current methods. Objective To correlate multislice volumetric 2-D MRTI volumes with histologically confirmed regions of tissue damage in MRgRA NBTU. Methods Seven swine underwent a total of 8 frontal MRgRA NBTU lesions. MRTI ablation volumes were compared to histologic tissue damage on brain sections stained with 2,3,5-triphenyltetrazolium chloride (TTC). Bland-Altman analyses and correlation trends were used to compare MRTI and TTC ablation volumes. Results Data from the initial and third swine’s ablations were excluded due to sub-optimal tissue staining. For the remaining ablations (n = 6), the limits of agreement between the MRTI and histologic volumes ranged from −0.149 cm3 to 0.252 cm3 with a mean difference of 0.052 ± 0.042 cm3 (11.1%). There was a high correlation between the MRTI and histology volumes (r 2 = 0.831) with a strong linear relationship (r = 0.868). Conclusion We used a volumetric MRTI technique to accurately track thermal changes during MRgRA NBTU in preparation for human trials. Improved volumetric coverage with MRTI enhanced our delivery of therapy and has far-reaching implications for focused ultrasound in the broader clinical setting.
BACKGROUND: Models have been developed for predicting ideal contact and amplitude for subthalamic nucleus (STN) deep brain stimulation (DBS) for Parkinson disease (PD). Pulse-width is generally varied to modulate the size of the energy field produced. Effects of varying frequency in humans have not been systematically evaluated. OBJECTIVE: To examine how altered frequencies affect blood oxygen level-dependent activation in PD. METHODS: PD subjects with optimized DBS programming underwent functional magnetic resonance imaging (fMRI). Frequency was altered and fMRI scans/Unified Parkinson Disease Rating Scale motor subunit (UPDRS-III) scores were obtained. Analysis using DBS-OFF data was used to determine which regions were activated during DBS-ON. Peak activity utilizing T-values was obtained and compared. RESULTS: At clinically optimized settings (n = 14 subjects), thalamic, globus pallidum externa (GPe), and posterior cerebellum activation were present. Activation levels significantly decreased in the thalamus, anterior cerebellum, and the GPe when frequency was decreased (P < .001). Primary somatosensory cortex activation levels significantly decreased when frequency was increased by 30 Hz, but not 60 Hz. Sex, age, disease/DBS duration, and bilaterality did not significantly affect the data. Retrospective analysis of fMRI activation patterns predicted optimal frequency in 11/14 subjects. CONCLUSION: We show the first data with fMRI of STN DBS-ON while synchronizing cycling with magnetic resonance scanning. At clinically optimized settings, an fMRI signature of thalamic, GPe, and posterior cerebellum activation was seen. Reducing frequency significantly decreased thalamic, GPe, and anterior cerebellum activation. Current standard-of-care programming can take up to 6 mo using UPDRS-III testing alone. We provide preliminary evidence that using fMRI signature of frequency may have clinical utility and feasibility.
Purpose Thermotherapy-based interventional technologies have rapidly developed as means to treat several pathologies. Ablative therapies have become especially useful in the treatment of movement disorders and brain tumors.[1–3] These procedures are typically monitored by magnetic resonance temperature imaging (MRTI), using the proton resonance frequency (PRFS) method.[4] The PRFS method is very sensitive to image phase artifacts, and therefore much care must be given to ablation probe design to minimize susceptibility-induced image artifacts. Interstitial MR-guided focused ultrasound (iMRgFUS) probes contain metal wires, piezoelectric material and water flow lines for cooling, all of which have the potential to cause drastic MRTI degradation. Here we (i) perform quantitative ΔB0, SNR, B1+ phantom tests on a recently developed catheter based iMRgFUS probe [5] in various orientations and power states, and (ii) perform phantom MRTI heating validation tests at multiple sonication power levels using 4 different MRTI sequences. The goal of this work is to evaluate, optimize and down-select MRTI protocols in order to achieve maximum temperature measurement precision and volume coverage in the presence of image artifacts arising from the iMRgFUS probe design and operation. In this work we evaluate a newly developed catheter-based therapeutic ultrasound (US) probe used for interstitial MR-guided high intensity focused US (iMRgFUS) procedures. Specifically, we optimize and down-select MR thermal imaging protocols in order to achieve maximum temperature measurement precision and volume coverage in the presence of image artifacts arising from the iMRgFUS probe design and operation.
The primary objective of cancer intervention is the selective removal of malignant cells while conserving surrounding healthy tissues. However, the accessibility, size and shape of the cancer can make achieving appropriate margins a challenge. One minimally invasive treatment option for these clinical cases is interstitial needle based therapeutic ultrasound (NBTU). In this work, we develop a finite element model (FEM) capable of simulating continuous rotation of a directional NBTU applicator. The developed model was used to simulate the thermal deposition for different rotation trajectories. The actual thermal deposition patterns for the simulated trajectories were then evaluated using magnetic resonance thermal imaging (MRTI) in a porcine skin gelatin phantom. An MRI-compatible robot was used to control the rotation motion profile of the physical NBTU applicator to match the simulated trajectory. The model showed agreement when compared to experimental measurements with Pearson correlation coefficients greater than 0.839 when comparing temperature fields within an area of 12.6 mm radius from the ultrasound applicator. The average temperature error along a 6.3 mm radius profile from the applicator was $1.27\;^\circ\mathrm{C}$. The model was able to compute 1 s of thermal deposition by the applicator in 0.2 s on average with a 0.1 mm spatial resolution and 0.5 s time steps. The developed simulation demonstrates performance suitable for real-time control which may enable robotically-actuated closed-loop conformal tumor ablation.
Background Deep brain stimulation (DBS) is a well-accepted treatment of Parkinson's disease (PD). Motor phenotypes include tremor-dominant (TD), akinesia-rigidity (AR), and postural instability gait disorder (PIGD). The mechanism of action in how DBS modulates motor symptom relief remains unknown. Objective Blood oxygen level-dependent (BOLD) functional magnetic resonance imaging (fMRI) was used to determine whether the functional activity varies in response to DBS depending on PD phenotypes. Materials and Methods Subjects underwent an fMRI scan with DBS cycling ON and OFF. The effects of DBS cycling on BOLD activation in each phenotype were documented through voxel-wise analysis. For each region of interest, ANOVAs were performed using T-values and covariate analyses were conducted. Further, a correlation analysis was performed comparing stimulation settings to T-values. Lastly, T-values of subjects with motor improvement were compared to those who worsened. Results As a group, BOLD activation with DBS-ON resulted in activation in the motor thalamus (p < 0.01) and globus pallidus externa (p < 0.01). AR patients had more activation in the supplementary motor area (SMA) compared to PIGD (p < 0.01) and TD cohorts (p < 0.01). Further, the AR cohort had more activation in primary motor cortex (MI) compared to the TD cohort (p = 0.02). Implanted nuclei (p = 0.01) and phenotype (p = <0.01) affected activity in MI and phenotype alone affected SMA activity (p = <0.01). A positive correlation was seen between thalamic activation and pulse-width (p = 0.03) and between caudate and total electrical energy delivered (p = 0.04). Conclusions These data suggest that DBS modulates network activity differently based on patient motor phenotype. Improved understanding of these differences may further our knowledge about the mechanisms of DBS action on PD motor symptoms and to optimize treatment.
PurposeTo develop a highly efficient magnetic field gradient coil for head imaging that achieves 200 mT/m and 500 T/m/s on each axis using a standard 1 MVA gradient driver in clinical whole‐body 3.0T MR magnet.MethodsA 42‐cm inner diameter head‐gradient used the available 89‐ to 91‐cm warm bore space in a whole‐body 3.0T magnet by increasing the radial separation between the primary and the shield coil windings to 18.6 cm. This required the removal of the standard whole‐body gradient and radiofrequency coils. To achieve a coil efficiency ~4× that of whole‐body gradients, a double‐layer primary coil design with asymmetric x‐y axes, and symmetric z‐axis was used. The use of all‐hollow conductor with direct fluid cooling of the gradient coil enabled ≥50 kW of total heat dissipation.ResultsThis design achieved a coil efficiency of 0.32 mT/m/A, allowing 200 mT/m and 500 T/m/s for a 620 A/1500 V driver. The gradient coil yielded substantially reduced echo spacing, and minimum repetition time and echo time. In high b = 10,000 s/mm2 diffusion, echo time (TE) < 50 ms was achieved (>50% reduction compared with whole‐body gradients). The gradient coil passed the American College of Radiology tests for gradient linearity and distortion, and met acoustic requirements for nonsignificant risk operation.ConclusionsUltra‐high gradient coil performance was achieved for head imaging without substantial increases in gradient driver power in a whole‐body 3.0T magnet after removing the standard gradient coil. As such, any clinical whole‐body 3.0T MR system could be upgraded with 3‐4× improvement in gradient performance for brain imaging.
BackgroundWith growing numbers of patients receiving deep brain stimulation (DBS), radiologists are encountering these neuromodulation devices at an increasing rate. Current MRI safety guidelines, however, limit MRI access in these patients.PurposeTo describe an MRI (1.5 T and 3 T) experience and safety profile in a large cohort of participants with active DBS systems and characterize the hardware-related artifacts on images from functional MRI.Materials and MethodsIn this prospective study, study participants receiving active DBS underwent 1.5- or 3-T MRI (T1-weighted imaging and gradient-recalled echo [GRE]-echo-planar imaging [EPI]) between June 2017 and October 2018. Short- and long-term adverse events were tracked. The authors quantified DBS hardware-related artifacts on images from GRE-EPI (functional MRI) at the cranial coil wire and electrode contacts. Segmented artifacts were then transformed into standard space to define the brain areas affected by signal loss. Two-sample t tests were used to assess the difference in artifact size between 1.5- and 3-T MRI.ResultsA total of 102 participants (mean age ± standard deviation, 60 years ± 11; 65 men) were evaluated. No MRI-related short- and long-term adverse events or acute changes were observed. DBS artifacts were most prominent near the electrode contacts and over the frontoparietal cortical area where the redundancy of the extension wire is placed subcutaneously. The mean electrode contact artifact diameter was 9.3 mm ± 1.6, and 1.9% ± 0.8 of the brain was obscured by the coil artifact. The coil artifacts were larger at 3 T than at 1.5 T, obscuring 2.1% ± 0.7 and 1.4% ± 0.7 of intracranial volume, respectively (P < .001). The superficial frontoparietal cortex and deep structures neighboring the electrode contacts were most commonly obscured.ConclusionWith a priori local safety testing, patients receiving deep brain stimulation may safely undergo 1.5- and 3-T MRI. Deep brain stimulation hardware-related artifacts only affect a small proportion of the brain.© RSNA, 2019Online supplemental material is available for this article.See also the editorial by Martin in this issue.
BACKGROUND: Chronic pain occurs in 83% of Parkinson disease (PD) patients and deep brain stimulation (DBS) has shown to result in pain relief in a subset of patients, though the mechanism is unclear. OBJECTIVE: To compare functional magnetic resonance imaging (MRI) data in PD patients with chronic pain without DBS, those whose pain was relieved (PR) with DBS and those whose pain was not relieved (PNR) with DBS. METHODS: Functional MRI (fMRI) with blood oxygen level-dependent activation data was obtained in 15 patients in control, PR, and PNR patients. fMRI was obtained in the presence and absence of a mechanical stimuli with DBS ON and DBS OFF. Voxel-wise analysis using pain OFF data was used to determine which regions were altered during pain ON periods. RESULTS: At the time of MRI, pain was scored a 5.4 1.2 out of 10 in the control, 4.25 +/- 1.18 in PNR, and 0.8 +/- 0.67 in PR cohorts. Group analysis of control and PNR groups showed primary somatosensory (SI) deactivation, whereas PR patients showed thalamic deactivation and SI activation. DBS resulted in more decreased activity in PR than PNR (P < .05) and more activity in anterior cingulate cortex (ACC) in PNR patients (P < .05). CONCLUSION: Patients in the control and PNR groups showed SI deactivation at baseline in contrast to the PR patients who showed SI activation. With DBS ON, the PR cohort had less activity in SI, whereas the PNR had more anterior cingulate cortex activity. We provide pilot data that patients whose pain responds to DBS may have a different fMRI signature than those who do not, and PR and PNR cohorts produced different brain responses when DBS is employed.
Purpose To establish peripheral nerve stimulation (PNS) thresholds for an ultra-high performance magnetic field gradient subsystem (simultaneous 200-mT/m gradient amplitude and 500-T/m/s gradient slew rate; 1 MVA per axis [MAGNUS]) designed for neuroimaging with asymmetric transverse gradients and 42-cm inner diameter, and to determine PNS threshold dependencies on gender, age, patient positioning within the gradient subsystem, and anatomical landmarks. Methods The MAGNUS head gradient was installed in a whole-body 3T scanner with a custom 16-rung bird-cage transmit/receive RF coil compatible with phased-array receiver brain coils. Twenty adult subjects (10 male, mean +/- SD age = 40.4 +/- 11.1 years) underwent the imaging and PNS study. The tests were repeated by displacing subject positions by 2-4 cm in the superior-inferior and anterior-posterior directions. Results The x-axis (left-right) yielded mostly facial stimulation, with mean Delta G(min) = 111 +/- 6 mT/m, chronaxie = 766 +/- 76 mu sec. The z-axis (superior-inferior) yielded mostly chest/shoulder stimulation (123 +/- 7 mT/m, 620 +/- 62 mu sec). Y-axis (anterior-posterior) stimulation was negligible. X-axis and z-axis thresholds tended to increase with age, and there was negligible dependency with gender. Translation in the inferior and posterior directions tended to increase the x-axis and z-axis thresholds, respectively. Electric field simulations showed good agreement with the PNS results. Imaging at MAGNUS gradient performance with increased PNS threshold provided a 35% reduction in noise-to-diffusion contrast as compared with whole-body performance (80 mT/m gradient amplitude, 200 T/m/sec gradient slew rate). Conclusion The PNS threshold of MAGNUS is significantly higher than that for whole-body gradients, which allows for diffusion gradients with short rise times (under 1 msec), important for interrogating brain microstructure length scales.
Background: Most fMRI studies on pain perception utilized thermal stimuli due to the lack of a non-metallic reliable, reproducible mechanical stimulus. We explored 2 potential MR compatible mechanical devices and validated one that induced changes on fMRI. Purpose: To validate a noxious mechanical stimulus MR compatible device in a healthy cohort and a chronic pain cohort. Further to ensure this device caused changes on fMRI compared to a pressure device. Methods: Two-healthy controls underwent fMRI scans in the presence/absence of mechanical noxious stimuli using different devices. A paradigm for administering the stimuli with the most robust responses on fMRI was developed. Reproducibility of the device was confirmed in 10 chronic pain patients and age/gender-matched healthy controls. Comparisons of patient demographics including age, sex, and numerical rating scale (NRS) scores between the cohorts were performed using a two-sample t-test. Reproducibility was assessed through repeated-measures ANOVA. Results: Both devices, when administered at 15 seconds on, 30 seconds off induced primary somatosensory cortex (SI) activation on fMRI. The device affecting the nail bed induced consistent discomfort and was subsequently validated. Specifically, a mean pressure of 15.7 ± 0.05 psi induced discomfort that remained consistent over repeated trials (p=0.74). Further, in healthy controls, there was a significant correlation between pressure applied and NRS scores in controls(p<0.01). In chronic pain patients, a mean pressure of 15.3 ± 0.10 psi provided discomfort during a single trial. This pressure did not differ than that found in healthy controls (p=0.26). Conclusion: We have developed and validated a novel pressure device which is MRI compatible and provides for improved accuracy. We have demonstrated increased reproducibility compared to existing devices in literature and documented feasibility in pilot fMRI studies. Future work will focus on demonstrating its use in fMRI studies in chronic pain patients.
BackgroundThe majority of Parkinson's disease patients with deep brain stimulation (DBS) use a monopolar configuration, which presents challenges for EEG and MRI studies. The literature reports algorithms to convert monopolar to bipolar settings.Purpose/HypothesisTo assess brain responses of Parkinson's disease patients implanted with DBS during fMRI studies using their clinical and presumed equivalent settings using a published conversion recipe.Study TypeProspective.SubjectsThirteen DBS patients.Field Strength/Sequence1.5T and 3T, fMRI using gradient echo‐planar imaging.AssessmentPatients underwent 30/30sec ON/OFF DBS fMRI scans using monopolar and bipolar settings. To convert to a bipolar setting, the negative contact used for the monopolar configuration remained constant and the adjacent dorsal contact was rendered positive, while increasing the voltage by 30%. fMRI activation/deactivation maps and motor Unified Parkinson's Disease Rating Scale (UPDRS‐III) scores were compared for patients in both configurations.Statistical Tests T‐tests were used to compare UPDRS scores and volumes of tissue activated (VTA) diameters in monopolar and bipolar configurations.ResultsThe patterns of fMRI activation in the monopolar and bipolar configurations were generally different. The thalamus, pallidum, and visual cortices exhibited higher activation using the patient's clinical settings than the presumed equivalent settings. VTA diameters were lower (7 mm vs. 6.3 mm, P = 0.047) and UPDRS scores were generally higher in the bipolar (33.2 ± 16) than in the monopolar configuration (28.3 ± 17.4), without reaching statistical significance (P > 0.05).Data ConclusionMonopolar and bipolar configurations result in different patterns of brain activation while using a previously published monopolar–bipolar conversion algorithm. Clinical benefits may be achieved with varying patterns of brain responses. Blind conversion from one to the other should be avoided for purposes of understanding the mechanisms of DBS.Level of Evidence: 1Technical Efficacy: Stage 1J. Magn. Reson. Imaging 2018.
PurposeTo build and evaluate a small‐footprint, lightweight, high‐performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole‐body clinical 3T MRI scanners, while achieving substantial reductions in installation costs.MethodsA conduction‐cooled magnet was developed that uses less than 12 liters of liquid helium in a gas‐charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42‐cm inner‐diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet‐gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80‐mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1‐MVA gradient drivers.ResultsIn a comparison of anatomical imaging in 16 patients using T2‐weighted 3D fluid‐attenuated inversion recovery (FLAIR) between the compact 3T and whole‐body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80‐mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain.ConclusionsThe compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole‐body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.
Test disk electrodes were fabricated from carbon nanotubes (CNT) using the Carbon Nanotube Templated Microfabrication (CNT-M) technique. The CNT-M process uses patterned growth of carbon nanotube forests from surfaces to form complex patterns, enabling electrode sizing and shaping. The additional carbon infiltration process stabilizes these structures for further processing and handling. At a macroscopic scale, the electrochemical, electrical and magnetic properties, and magnetic resonance imaging (MRI) characteristics of the disk electrodes were investigated; their microstructure was also assessed. CNT disk electrodes showed electrical resistivity around 1 Omega.cm, charge storage capacity between 3.4 and 38.4 mC/cm(2), low electrochemical impedance and magnetic susceptibility of -5.9 to -8.1 ppm, closely matched to that of tissue (similar to-9 ppm). Phantom MR imaging experiments showed almost no distortion caused by these electrodes compared with Cu and Pt-Ir reference electrodes, indicating the potential for significant improvement in accurate tip visualization. (C) 2018 Elsevier Inc. All rights reserved.
We developed a magnetic resonance compatible real-time, three-dimensional imaging ultrasound probe for motion management of radiation therapy for liver cancer. The probe contains an 18,000-element, 46.8 mm × 21.5 mm matrix array constructed from three tiled transducer modules with integrated beamforming ASICs. The center frequency and -6 dB fractional bandwidth of the probe was 3.6 MHz and 85 percent respectively. Ferromagnetic materials in the acoustic stack, flex interconnect and electronics boards were greatly minimized for magnetic resonance compatibility. The probe and cable were shielded to minimize the impact of radiofrequency noise on both the ultrasound and magnetic resonance images. The probe's low-profile, side-viewing design allows it to be strapped to a patient so that images may be acquired hands-free. We present simultaneously acquired ultrasound and 3 Tesla magnetic resonance images with minimal artifacts in both images.
Surface coils are widely used in magnetic resonance imaging and spectroscopy. While smaller diameter coils produce higher signal to noise ratio (SNR) closer to the coil, imaging larger fields of view or greater distance into the sample requires a larger overall size array or, in the case of a channel count limited system, larger diameter coils. In this work, we consider reconfiguring the geometry of coils and coil arrays such that the same coil or coil array may be used in multiple field of view imaging. A custom designed microelectromechanical systems switch, compatible with magnetic resonance imaging, is used to switch in/out conductive sections and components to reconfigure coils. The switch does not degrade the SNR and can be opened/closed in 10 μs, leading to rapid reconfiguration. Results from a single coil, configurable between small/large configurations, and a two-coil phased array, configurable between spine/torso modes, are presented.