Purpose: This phase 1 study (NCT04370873) evaluated safety and pharmacokinetics/pharmacodynamics (PK/PD) of MK -5475 in participants with pulmonary hypertension associated with COPD (PH-COPD). Methods: Eligible participants were 40-80 years old with COPD (FEV 1 /FVC <0.7; FEV 1 >30% predicted) and PH (mean pulmonary arterial pressure >= 25 mmHg). Participants were randomized 2:1 to MK -5475 or placebo via dry -powder inhaler once daily for 7 days in Part 1 (360 mu g) or 28 days in Part 2 (380 mu g). Safety was assessed by adverse events (AEs) and arterial blood oxygenation. Part -2 participants had pulmonary vascular resistance (PVR; primary PD endpoint) and pulmonary blood volume (PBV; secondary PD endpoint) measured at baseline and Day 28. A non -informative prior was used to calculate posterior probability (PP) that the betweengroup difference (MK -5475 - placebo) in mean percent reduction from baseline in PVR was less than -15%. Results: Nine participants were randomized in Part 1, and 14 participants in Part 2. Median age of participants (86.4% male) was 68.5 years (41-77 years); 95.5% had moderate -to -severe COPD. Incidences of AEs were comparable between MK -5475 and placebo: overall (5/14 [36%] versus 5/8 [63%]), drug -related (1/14 [7%] versus 2/8 [25%]), and serious (1/14 [7%] versus 1/8 [13%]). MK5475 caused no meaningful changes in arterial blood oxygenation or PBV. MK -5475 versus placebo led to numerical improvements from baseline in PVR (-21.2% [95% CI: -35.4, -7.0] versus -5.4% [95% CI: -83.7, 72.9]), with between -group difference in PVR less than -15% and calculated PP of 51%. Conclusion: The favorable safety profile and numerical reductions in PVR observed support further clinical development of inhaled MK -5475 for PH-COPD treatment.
Many commercially available biologics, previously delivered only intravenously, are being re-formulated for subcutaneous delivery to improve patient access and compliance. However, due to inherent solubility limitations, large volume injections (more than 2 mL) are typically required. Different strategies are being explored to improve the tolerability of such injections, including the co-formulation with hyaluronidase and/or implementing different needle designs. While there have been separate reports of measuring injection forces and using imaging to track injection delivery and tissue response, there is no current set of methods to simultaneously characterize the injection delivery (bleb) and measure injection pressures. In this study we describe the development of Computed Tomography imaging methods in minipigs to characterize the morphology of the bleb following injection, along with inline pressure measurements to assess subcutaneous pressure during injection using two different injection volumes, 4.5 mL and 9 mL. We show that these parameters change with injection volume, and that inclusion of hyaluronidase in the injection increases bleb dispersion and reduces skin distention while also lowering the injection pressure. This method will likely be a valuable tool for assessing and comparing different injection delivery methods and formulations.
Background: Novel therapeutics for pulmonary arterial hypertension (PAH) with improved safety/tolerability profiles are needed to address continued high rates of morbidity/mortality. Methods: This Phase 1 study evaluated efficacy/safety of inhaled single-dose MK-5475, an investigational, small-molecule stimulator of soluble guanylate cyclase designed for inhaled delivery via a dry-powder inhaler device, in participants with PAH (Clinicaltrials.gov: NCT03744637). Eligible participants were 18-70 years of age; body mass index <= 35 kg/m(2); diagnosis of PAH (Group 1 pulmonary hypertension). In Part 1, participants received double-blind MK-5475 or placebo for safety assessment (primary outcome). In Part 2, 4 panels participated in <= 3 open-label periods. Part 2/Period 1 assessed safety/tolerability. Part 2/Periods 2 and 3, respectively, involved functional respiratory imaging for measuring pulmonary blood volume (secondary outcome) and right heart catheterization for measuring pulmonary vascular resistance (primary outcome). Results: MK-5475 was generally well tolerated without systemic side effects on blood pressure or heart rate up to 24 h post dose. With respect to the primary pharmacodynamic outcome, mean reductions in pulmonary vascular resistance ranged from 21% to 30% across 120 mu g and 360 mu g doses. Conclusions: Treatment with inhaled single-dose MK-5475 showed rapid and sustained reductions in pulmonary vascular resistance and increases in pulmonary blood volume. MK-5475 was generally well tolerated versus placebo without vasodilatory systemic side effects. The promising pulmonary selectivity and favorable safety/tolerability profile of MK-5475 seen in this study of adult participants with PAH lays the foundation for further clinical development.
Kidney diseases such as acute kidney injury, diabetic nephropathy and chronic kidney disease (CKD) are related to dysfunctions of the microvasculature in the kidney causing a decrease in renal blood perfusion (RBP). Pharmacological intervention to improve the function of the microvasculature is a viable strategy for the potential treatment of these diseases. The measurement of RBP is a reliable biomarker to evaluate the efficacy of pharmacological agents' actions on the microvasculature, and measurement of RBP responses to different pharmacological agents can also help elucidate the mechanism of hemodynamic regulation in the kidney. Magnetic resonance imaging (MRI) with flow-sensitive alternating inversion recovery (FAIR) arterial spin labeling (ASL) has been used to measure RBP in humans and animals. However, artifacts caused by respiratory and peristaltic motions limit the potential of FAIR ASL in drug discovery and kidney research. In this study, the combined anesthesia protocol of inactin with a low dose of isoflurane was used to fully suppress peristalsis in rats, which were ventilated with an MRI-synchronized ventilator. FAIR ASL data were acquired in eight axial slices using a single-shot, gradient-echo, echo-planar imaging (EPI) sequence. The artifacts in the FAIR ASL RBP measurement due to respiratory and peristaltic motions were substantially eliminated. The RBP responses to fenoldopam and L-NAME were measured, and the increase and decrease in RBP caused by fenoldopam and L-NAME, respectively, were robustly observed. To further validate FAIR ASL, the renal blood flow (RBF) responses to the same agents were measured by an invasive perivascular flow probe method. The pharmacological agent-induced responses in RBP and RBF are similar. This indicates that FAIR ASL has the sensitivity to measure pharmacologically induced changes in RBP. FAIR ASL with multislice EPI can be a valuable tool for supporting drug discovery, and for elucidating the mechanism of hemodynamic regulation in kidneys.
Kidney diseases such as acute kidney injury, diabetic nephropathy and chronic kidney disease (CKD) are related to dysfunctions of the microvasculature in the kidney causing a decrease in renal blood perfusion (RBP). Pharmacological intervention to improve the function of the microvasculature is a viable strategy for the potential treatment of these diseases. The measurement of RBP is a reliable biomarker to evaluate the efficacy of pharmacological agents' actions on the microvasculature, and measurement of RBP responses to different pharmacological agents can also help elucidate the mechanism of hemodynamic regulation in the kidney. Magnetic resonance imaging (MRI) with flow‐sensitive alternating inversion recovery (FAIR) arterial spin labeling (ASL) has been used to measure RBP in humans and animals. However, artifacts caused by respiratory and peristaltic motions limit the potential of FAIR ASL in drug discovery and kidney research. In this study, the combined anesthesia protocol of inactin with a low dose of isoflurane was used to fully suppress peristalsis in rats, which were ventilated with an MRI‐synchronized ventilator. FAIR ASL data were acquired in eight axial slices using a single‐shot, gradient‐echo, echo‐planar imaging (EPI) sequence. The artifacts in the FAIR ASL RBP measurement due to respiratory and peristaltic motions were substantially eliminated. The RBP responses to fenoldopam and L‐NAME were measured, and the increase and decrease in RBP caused by fenoldopam and L‐NAME, respectively, were robustly observed. To further validate FAIR ASL, the renal blood flow (RBF) responses to the same agents were measured by an invasive perivascular flow probe method. The pharmacological agent‐induced responses in RBP and RBF are similar. This indicates that FAIR ASL has the sensitivity to measure pharmacologically induced changes in RBP. FAIR ASL with multislice EPI can be a valuable tool for supporting drug discovery, and for elucidating the mechanism of hemodynamic regulation in kidneys.
Abstract This short report describes the measurement of total liver blood flow in commonly used laboratory rats using the relatively non‐invasive approach of ultrasound imaging. A total of 29 rats (n = 26 Wistar‐Han, n = 3 Sprague–Dawley) were imaged and both male and female rats were included. The mean (SD) total liver blood flow of all animals combined was 33.3 ± 7.8 mL/min, or 104.3 ± 17.1 mL/min/kg when normalized to observed body weight at the time of imaging. There was a trend for higher unnormalized total liver blood flow as body weight increased and the female rats had, in general, the lowest body weight and total liver blood flow of the animals studied. There were no major differences in total liver blood flow between the small number of Sprague–Dawley rats used in the study and the larger Wistar‐Han group. Further research would be needed to accurately characterize any subtle differences in body weight between rats of different strains, sexes, and body weight.