Introduction: Synthetic cannabinoids are a rapidly expanding subset of designer drugs widely available in the United States since 2008. In Illinois during the spring of 2018, over 160 documented cases of bleeding and prolonged coagulopathy occurred secondary to contaminated synthetic cannabinoids. Methods: We conducted a retrospective cohort study consisting of 38 patients to describe the initial emergency department (ED) presentation, diagnosis, and treatment. Results: Through serum testing we found that three long-acting anticoagulant rodenticides (LAAR) were detected in patients who had inhaled these tainted products: brodifacoum, difenacoum, and bromodialone. Discussion: This study encompasses the largest ED presentation of LAAR poisoning via the inhalational route known to date. Conclusion: The emergency physician should be aware of the potential for tainted coingestants as the cause of undifferentiated coagulopathy.
Abstract Background: An outbreak of synthetic cannabinoid (SC)-associated coagulopathy and bleeding in Illinois, USA was determined to be due to inhalation of SC contaminated with brodifacoum (BDF), difenacoum (DiF), and bromadiolone (BDL), highly potent long-acting anticoagulant rodenticides (LAARs). Treatment with high-dose vitamin K1 (VK1) prevented mortality; however, plasma LAAR levels were not measured risking recurrence of coagulopathy and bleeding due to premature discontinuation. The goal of this study was to determine if plasma LAAR levels were reduced following standard of care treatment to normalize coagulopathy. Methods: Blood samples were collected from a cohort of 32 patients, and ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis used to quantify plasma LAAR levels including enantiomers. Results: BDF was detected in 31 samples; 30 also contained DiF and 18 contained BDL. Initial plasma levels were 581 ± 87, 11.0 ± 1.9, and 14.9 ± 5.9 ng/mL for BDF, DiF, and BDL, respectively (mean ± SE). At discharge plasma, BDF levels remained elevated at 453 ± 68 ng/mL. Plasma half-lives for BDF, DiF, and BDL were 7.5 ± 1.3, 7.2 ± 1.9, and 1.8 ± 0.3 days, respectively. The half-life for trans-BDF enantiomers (5.7 ± 0.8 days) was shorter than for cis-enantiomers (7.6 ± 1.9 days). BDF half-lives were shorter, and coagulopathy normalized faster in patients receiving intravenous VK1 as compared to oral VK1. Patients prescribed VK1 at discharge had fewer re-admittances. Conclusions: These results demonstrate that plasma LAAR levels at discharge were elevated in poisoned patients despite normal coagulation, and that the route of VK1 administration affected LAAR pharmacokinetics and INR normalization. We propose plasma LAAR levels and coagulation be monitored concomitantly during follow-up of patients with LAAR poisoning. KEY POINTS In patients treated with high-dose vitamin K1 for LAAR poisoning, plasma levels remained 40-fold above safe levels upon discharge from hospital. LAAR half-lives, normalization of coagulopathy, and readmittances were reduced by treatment with intravenous vitamin K1.