High frequency dielectric measurements (300 kHz–3 GHz) have been used to assess the water uptake by bonded composite resin joint structures. Comparison of exposed and dry joints demonstrated that a correlation exists between changes with time in the dielectric properties of the joints and the extent of water uptake in the matrix as determined gravimetrically. Diffusion of water into the joints is discussed in terms of various models. The changes in mechanical properties as a function of water uptake are reported over an extended period of time. The use of dielectric measurements as a non-destructive examination method for the assessment of water ingress into joint structures is demonstrated.
Applications of high-frequency dielectric measurements (300 kHz to 3 GHz) to the non-destructive examination (NDE) of composite structures are discussed. Preliminary data indicate that the method, previously used for aluminium bonded structures, can be applied to bonded carbon fibre composite structures. Water ingress into the bond structure was observed to influence both the time- and the frequency-domain data. Comparison of exposed and dry joints demonstrated that a good correlation exists between changes with time in the dielectric properties of the composites and the extend of water uptake in the matrix. Parallel gravimetric measurements were also performed. Diffusion of water into the composite structures is discussed in terms of various models. This paper demonstrates that this NDE method may be used for assessment of the water content in the matrix and has general applicability to the study of carbon-reinforced matrix materials.