Purpose: To characterize the plastic scintillation detectors (PSDs) response in the diagnostic energy range. A fast and adaptable method for real‐time dosimetry in superficial x‐ray therapy and interventional radiology is proposed. Method: A PSD (1 mm diameter and 10 mm long) is coupled to a 5 m long optical fiber. Scintillation photons are guided to a polychromatic photodiode which provides an electrical current proportional to the input light signal. If the incident energy spectrum is known, the dose measured in the PSD's polystyrene sensitive volume can be converted to score dose in any other media such as air, water or soft tissues using the large cavity theory (LCT). A software simulating x‐ray tube spectra and filtration has been benchmarked and is used for analysis. The method is confirmed by Monte Carlo simulations. Results: PSDs cannot be assumed energy independent with low‐energy photons as a factor 2 has been observed in the energy response between 80 kVp and 150 kVp. When the dose is converted to the desired medium, the PSD's energy dependence is compensated and a 2.1% standard deviation was observed upon the studied energy ranges, which is inside the measurement and calculation uncertainties. Percent depth dose (PDD) measurements are in good agreement with Monte Carlo simulations and results can be improved if the proposed method is applied to compensate beam hardening. Conclusion: PSDs present great potential for real‐time dose measurements with radiologic photon energy.
A simple method to produce longer filaments with higher ionization density in air by controlling the diameter of an aperture in the laser beam path is studied via an analysis of the backscattered N(2) fluorescence collected by LIDAR. Significant increase in the fluorescence signal (approximately by a factor of five depending on the conditions) and an increased filament length was observed at an optimum diameter. 3D + time stochastic numerical simulations have shown that the optimum aperture size corresponds to the case of multiple filament 'squeezing' around the propagation axis forming the regularized elongated structure with higher overall amount of plasma. The optimum range of aperture sizes is the same for the initial transverse perturbation scale variation at least within a factor of three.
The mobile femtosecond laser facility T&T (terawatt & terahertz) of DRDC-Valcartier was used to detect trace methane gas remotely in an open field atmosphere during daytime (with strong sun light) using filament-induced fluorescence spectroscopy. Comparison of the results obtained in the laboratory and in the field validates the long range extrapolations of short distance results taken in our laboratory in the past. This could be considered a breakthrough for remote sensing based on filamentation.