The aim of this study was to protect the probiotic Bifidobacterium longum (strain 22348) against the harsh conditions in the stomach (e.g., acidic pH) and small intestine (e.g., exposure to bile salts and enzymes) upon oral administration, as well as against inactivation during storage (e.g., upon contact with oxygen). A variety of probiotic suspensions in water and phosphate buffer, optionally containing poly (methyl acrylate-co-methyl methacrylate-co-methacrylic acid, Eudraguard (R) biotic), inulin, alginate and maltodextrin were spray-dried under various conditions. The viability of the probiotic in the obtained powder was monitored upon exposure to 0.1 M HCl and phosphate buffer pH 6.8 containing 0-3 % bile salts. The viability of the bacterium was also monitored during storage at -20, 4 or 25 degrees C for 4 weeks. Interestingly, spray-drying a suspension of Bifidobacterium longum in phosphate buffer pH 7.4 containing 5.9 % Eudraguard (R) biotic, 2 % inulin, 0.1 % sodium alginate and 3 % maltodextrin using a B & uuml;chi-290 laboratory-scale spray dryer at an inlet temperature of 87 degrees C, aspirator flow rate of 31.5 m3/h, drying gas (N2) flow rate of 473 L/h and feed flow rate of 2.5 mL/min showed the most promising results. It allowed to effectively protect the probiotic: not only during manufacturing & storage, but also upon exposure to media mimicking the conditions in the stomach and small intestine. These process conditions also provided a high encapsulation efficiency (97 %) and production yield (90 %).
Objective The aim of this study is to detail and evaluate the surgical procedure for perilymph sampling from the cochlear apex in the Mongolian gerbil. Design Perilymph sampling from the cochlear apex was performed one to three time in 12 male gerbils aged 8 to 12 months via the submandibular route. 11 of them were previously implanted with intracochlear implants loaded with dexamethasone and placed in the scala tympani, the 12th was used to collect control samples. The procedure was performed under general gas anesthesia, with head support, by a submandibular approach. After opening the bulla and sacrificing the external and middle ears, the cochlea was exposed and perilymph sampled. Macroscopic features of perilymph samples were reported before an HPLC-MS/MS assay to detect and quantify dexamethasone. Some cochleae were then harvested, immunostained and cleared to study fibrosis formation along the labyrinth and evaluate the consequences of multiple sampling procedures. Results The perilymph sampling procedure was technically difficult and required experimenter training. The procedure was well tolerated by the animals. One drawback of this technique in our gerbil model was the need to sacrifice the external ear, eardrum and ossicular chain to allow sufficient exposure for a quality procedure. Our technique enabled the collection of perilymph samples of the desired volume. Most of our samples were contaminated by bleeding from the otic capsule bone secondary to the cochleostomy. Nevertheless, HPLC-MS/MS analyses which successfully found dexamethasone in the perilymph of implanted gerbils, confirmed that our method was suitable for pharmacokinetic analyses. The occurrence of areas of fibrosis in the labyrinth after a sampling procedure compromises the quality and reliability of subsequent samples from the same animal. Conclusion The Mongolian gerbil is an animal model that can be used to collect perilymph from the cochlear apex to perform pharmacokinetic studies. The number of samples taken from a single animal must be limited to one.
The production of short chain fatty acids (SCFAs) by the colonic microbiome has numerous benefits for human health, including maintenance of epithelial barrier function, suppression of colitis, and protection against carcinogenesis. Despite the therapeutic potential, there is currently no optimal approach for elevating the colonic microbiome's synthesis of SCFAs. In this study, poly(D,l-lactide-co-glycolide) (PLGA) was investigated for this application, as it was hypothesised that the colonic microbiota would metabolise PLGA to its lactate monomers, which would promote the resident microbiota's synthesis of SCFAs. Two grades of spray dried PLGA, alongside a lactate bolus control, were screened in an advanced model of the human colon, known as the M-SHIME® system. Whilst the high molecular weight (Mw) grade of PLGA was stable in the presence of the microbiota sourced from three healthy humans, the low Mw PLGA (PLGA 2) was found to be metabolised. This microbial degradation led to sustained release of lactate over 48 h and increased concentrations of the SCFAs propionate and butyrate. Further, microbial synthesis of harmful ammonium was significantly reduced compared to untreated controls. Interestingly, both types of PLGA were found to influence the composition of the luminal and mucosal microbiota in a donor-specific manner. An in vitro model of an inflamed colonic epithelium also showed the polymer to affect the expression of pro- and anti-inflammatory markers, such as interleukins 8 and 10. The findings of this study reveal PLGA's sensitivity to enzymatic metabolism in the gut, which could be harnessed for therapeutic elevation of colonic SCFAs.
Polysaccharides were identified, which allow for colon targeting in human Inflammatory Bowel Disease (IBD) patients, as well as in rats and dogs (which are frequently used as animals in preclinical studies). The polysaccharides are degraded by colonic enzymes (secreted by bacteria), triggering the onset of drug release at the target site. It has to be pointed out that the microbiota in rats, dogs and humans substantially differ. Thus, the performance of this type of colon targeting system observed in animals might not be predictive for patients. The aim of this study was to limit this risk. Different polysaccharides were exposed to culture medium inoculated with fecal samples from IBD patients, healthy dogs and “IBD rats” (in which colonic inflammation was induced). Dynamic changes in the pH of the culture medium were used as an indicator for the proliferation of the bacteria and, thus, the potential of the polysaccharides to serve as their substrate. Fundamental differences were observed with respect to the extent of the pH variations as well as their species-dependency. The most promising polysaccharides were used to prepare polymeric film coatings surrounding 5-aminosaliciylic acid (5-ASA)-loaded starter cores. To limit premature polysaccharide dissolution/swelling in the upper gastro intestinal tract, ethylcellulose was also included in the film coatings. Drug release was monitored upon exposure to culture medium inoculated with fecal samples from IBD patients, healthy dogs and “IBD rats”. For reasons of comparison, also 5-ASA release in pure culture medium was measured. Most film coatings showed highly species-dependent drug release kinetics or limited colon targeting capacity. Interestingly, extracts from aloe vera and reishi (a mushroom) showed a promising potential for colon targeting in all species.
Colonic drug delivery offers numerous pharmaceutical opportunities, including direct access to local therapeutic targets and drug bioavailability benefits arising from the colonic epithelium's reduced abundance of cytochrome P450 enzymes and particular efflux transporters. Current workflows for developing colonic drug delivery systems involve time-consuming, low throughput in vitro and in vivo screening methods, which hinder the identification of suitable enabling materials. Polysaccharides are useful materials for colonic targeting, as they can be utilised as dosage form coatings that are selectively digested by the colonic microbiota. However, polysaccharides are a heterogeneous family of molecules with varying suitability for this purpose. To address the need for high-throughput material selection tools for colonic drug delivery, we leveraged machine learning (ML) and publicly accessible experimental data to predict the release of the drug 5-aminosalicylic acid from polysaccharide-based coatings in simulated human, rat, and dog colonic environments. For the first time, Raman spectra alone were used to characterise polysaccharides for input as ML features. Models were validated on 8 unseen drug release profiles from new polysaccharide coatings, demonstrating the generalisability and reliability of the method. Further, model analysis facilitated an understanding of the chemical features that influence a polysaccharide's suitability for colonic drug delivery. This work represents a major step in employing spectral data for forecasting drug release from pharmaceutical formulations and marks a significant advancement in the field of colonic drug delivery. It offers a powerful tool for the efficient, sustainable, and successful development and pre-ranking of colon-targeted formulation coatings, paving the way for future more effective and targeted drug delivery strategies.
In-situ forming poly(lactic-co-glycolic acid) (PLGA) implants offer a great potential for controlled drug delivery for a variety of applications, e.g. periodontitis treatment. The polymer is dissolved in a water-miscible solvent. The drug is dissolved or dispersed in this solution. Upon contact with aqueous body fluids, the solvent diffuses into the surrounding tissue and water penetrates into the formulation. Consequently, PLGA precipitates, trapping the drug. Often, N-methyl-2-pyrrolidine (NMP) is used as a water-miscible solvent. However, parenteral administration of NMP raises toxicity concerns. The aim of this study was to identify less toxic alternative solvent systems for in-situ forming PLGA implants. Various blends of polyethylene glycol 400 (PEG 400), triethyl citrate (TEC) and ethanol were used to prepare liquid formulations containing PLGA, ibuprofen (as an antiinflammatory drug) and/or chlorhexidine dihydrochloride (as an antiseptic agent). Implant formation and drug release kinetics were monitored upon exposure to phosphate buffer pH 6.8 at 37 degrees C. Furthermore, the syringeability of the liquids, antimicrobial activity of the implants, and dynamic changes in the latter's wet mass and pH of the release medium were studied. Importantly, 85:10:5 and 60:30:10 PEG 400:TEC:ethanol blends provided good syringeability and allowed for rapid implant formation. The latter controlled ibuprofen and chlorhexidine release over several weeks and assured efficient antimicrobial activity. Interestingly, fundamental differences were observed concerning the underlying release mechanisms of the two drugs: Ibuprofen was dissolved in the solvent mixtures and partially leached out together with the solvents during implant formation, resulting in relatively pronounced burst effects. In contrast, chlorhexidine dihydrochloride was dispersed in the liquids in the form of tiny particles, which were effectively trapped by precipitating PLGA during implant formation, leading to initial lag-phases for drug release.
This study evaluated the potential of poly(ethylene vinyl acetate) (EVA) copolymers as matrix formers in miniaturised implants, allowing to achieve controlled drug delivery into the inner ear. Due to the blood-cochlea barrier, it is impossible to reliably deliver a drug to this tiny and highly sensitive organ in clinical practice. To overcome this bottleneck, different EVA implants were prepared by hot melt extrusion, altering the vinyl acetate content and implant diameter. Dexamethasone was incorporated as a drug with anti-inflammatory and anti-fibrotic activity. Its release was measured into artificial perilymph, and the systems were thoroughly characterised before and after exposure to the medium by optical and scanning electron microscopy, SEM-EDX analysis, DSC, X-ray powder diffraction, X-ray microtomography and texture analysis. Notably, the resulting drug release rates were much higher than from silicone-based implants of similar size. Furthermore, varying the vinyl acetate content allowed for adjusting the desired release patterns effectively: With decreasing vinyl acetate content, the crystallinity of the copolymer increased, and the release rate decreased. Interestingly, the drug was homogeneously distributed as tiny crystals throughout the polymeric matrices. Upon contact with aqueous fluids, water penetrates the implants and dissolves the drug, which subsequently diffuses out of the device. Importantly, no noteworthy system swelling or shrinking was observed for up to 10 months upon exposure to the release medium, irrespective of the EVA grade. Also, the mechanical properties of the implants can be expected to allow for administration into the inner ear of a patient, being neither too flexible nor too rigid.
In the present study, a novel in situ forming thermosensitive hydrogel system was investigated as a versatile drug delivery system for ocular therapy. For this purpose, two thermosensitive ABA triblock copolymers bearing either furan or maleimide moieties were synthesized, named respectively poly(NIPAM-co-HEA/Furan)-PEG(6K)-P (NIPAM-co-HEA/Furan) (PNF) and poly(NIPAM-co-HEA/Maleimide)-PEG6K-P(NIPAM-co-HEA/-Maleimide) (PNM). Hydrogels were obtained upon mixing aqueous PNF and PNM solutions followed by incubation at 37 & DEG;C. The hydrogel undergoes an immediate (<1 min) sol-gel transition at 37 & DEG;C. In situ hydrogel formation at 37 & DEG;C was also observed after intravitreal injection of the formulation into an ex vivo rabbit eye. The hydrogel network formation was due to physical self-assembly of the PNIPAM blocks and a catalyst-free furan-maleimide Diel-s-Alder (DA) chemical crosslinking in the hydrophobic domains of the polymer network. Rheological studies demonstrated sol-gel transition at 23 & DEG;C, and DA crosslinks were formed in time within 60 min by increasing the temperature from 4 to 37 & DEG;C. When incubated at 37 & DEG;C, these hydrogels were stable for at least one year in phosphate buffer of pH 7.4. However, the gels degraded at basic pH 10 and 11 after 13 and 3 days, respectively, due to hydrolysis of ester bonds in the crosslinks of the hydrogel network. The hydrogel was loaded with an anti-VEGF antibody fragment (FAB; 48.4 kDa) or with corticosteroid dexamethasone (dex) by dissolving (FAB) or dispersing (DEX) in the hydrogel precursor solution. The FAB fragment in unmodified form was quantitatively released over 13 days after an initial burst release of 46, 45 and 28 % of the loading for the 5, 10 and 20 wt% hydrogel, respectively, due to gel dehydration during formation. The low molecular weight drug dexamethasone was almost quantitively released in 35 days. The slower release of dexamethasone compared to the FAB fragment can likely be explained by the solubilization of this hydrophobic drug in the hydrophobic domains of the gel. The thermosensitive gels showed good cytocompatibility when brought in contact with macrophage-like mural cells (RAW 264.7) and human retinal pigment epithelium-derived (ARPE-19) cells. This study demonstrates that PNF-PNM thermogel may be a suitable formulation for sustained release of bioactive agents into the eye for treating posterior segment eye diseases.
Different types of ibuprofen-loaded, poly (D,L lactic-co-glycolic acid) (PLGA)-based implants were prepared by 3D printing (Droplet Deposition Modeling). The theoretical filling density of the mesh-shaped implants was varied from 10 to 100%. Drug release was measured in agarose gels and in well agitated phosphate buffer pH 7.4. The key properties of the implants (and dynamic changes thereof upon exposure to the release media) were monitored using gravimetric measurements, optical microscopy, Differential Scanning Calorimetry, Gel Perme-ation Chromatography, and Scanning Electron Microscopy. Interestingly, drug release was similar for implants with 10 and 30% filling density, irrespective of the experimental set-up. In contrast, implants with 100% filling density showed slower release kinetics, and the shape of the release curve was altered in agarose gels. These observations could be explained by the existence (or absence) of a continuous aqueous phase between the polymeric filaments and the "orchestrating role" of substantial system swelling for the control of drug release. At lower filling densities, it is sufficient for the drug to be released from a single filament. In contrast, at high filling densities, the ensemble of filaments acts as a much larger (more or less homogeneous) polymeric matrix, and the average diffusion pathway to be overcome by the drug is much longer. Agarose gel (mimicking living tissue) hinders substantial PLGA swelling and delays the onset of the final rapid drug release phase. This improved mechanistic understanding of the control of drug release from PLGA-based 3D printed implants can help to facilitate the optimization of this type of advanced drug delivery systems.
3D Printing offers a considerable potential for personalized medicines. This is especially true for customized biodegradable implants, matching the specific needs of each patient. Poly(lactic-co-glycolic acid) (PLGA) is frequently used as matrix former in biodegradable implants. However, yet relatively little is known on the technologies, which can be used for the 3D printing of PLGA implants. The aim of this study was to compare: (i) Arburg Plastic Freeforming Droplet Deposition Modeling (APF DDM), and (ii) Fused Deposition Modeling (FDM) to print mesh-shaped, ibuprofen-loaded PLGA implants. During APF DDM, individual drug-polymer droplets are deposited, fusing together to form filaments, which build up the implants. During FDM, continuous drug-polymer filaments are deposited to form the meshes. The implants were thoroughly characterized before and after exposure to phosphate buffer pH 7.4 using optical and scanning electron microscopy, GPC, DSC, drug release measurements and monitoring dynamic changes in the systems' dry & wet mass and pH of the bulk fluid. Interestingly, the mesh structures were significantly different, although the device design (composition & theoretical geometry) were the same. This could be explained by the fact that the deposition of individual droplets during APF DDM led to curved and rather thick filaments, resulting in a much lower mesh porosity. In contrast, FDM printing generated straight and thinner filaments: The open spaces between them were much larger and allowed convective mass transport during drug release. Consequently, most of the drug was already released after 4 d, when substantial PLGA set on. In the case of APF DDM printed implants, most of the drug was still entrapped at that time point and substantial polymer swelling transformed the meshes into more or less continuous PLGA gels. Hence, the diffusion pathways became much longer and ibuprofen release was controlled over 2 weeks.
Mixtures of hyaluronic acid (HA, in the semi-dilute entangled regime) with liposomes (high lipid concentration) exhibit a great interest in drug delivery. Considering the difference of microstructures when varying the liposome surface, we aimed to determine if liposome characteristics (surface and size) also influenced their release from these hybrid systems and to explore the mechanisms involved. Small-angle neutron scattering, cryogenic electron microscopy, zetametry, and dynamic light scattering were used to characterize liposomes. The implemented Transwell® model (two compartments separated by a polycarbonate membrane) showed that both size and surface governed liposome release. At 150 nm, anionic liposomes with or without poly(ethylene glycol) chains (PEG) migrated from HA-liposome mixtures, while cationic and neutral ones did not. Furthermore, increasing the size of PEGylated liposomes up to 200 nm or more strongly hindered their migration. Below 200 nm, the smaller the liposome size, the faster the release. Multiple and complex mechanisms (interactions between HA and liposomes, water exchanges, liposome migration, swelling and erosion, and HA reptation) were involved. Their relative importance depended on liposome characteristics. The Transwell® model is a pertinent tool to assess in vitro the release of liposomes over several weeks and discriminate the formulations, depending on the foreseen therapeutic strategy.
Dexamethasone-loaded silicone matrices offer an interesting potential as innovative drug delivery systems, e.g. for the treatment of inner ear diseases or for pacemakers. Generally, very long drug release periods are targeted: several years/decades. This renders the development and optimization of novel drug products cumbersome: experimental feedback on the impact of the device design is obtained very slowly. A better understanding of the underlying mass transport mechanisms can help facilitating research in this field. A variety of silicone films were prepared in this study, loaded with amorphous or crystalline dexamethasone. Different polymorphic drug forms were investigated, the film thickness was altered and the drug optionally partially/completely exchanged by much more water-soluble dexamethasone 'phosphate'. Drug release studies in artificial perilymph, scanning electron microscopy, optical microscopy, differential scanning calorimetry, X-ray diffraction and Raman imaging were used to elucidate the physical states of the drugs and polymer, and of the systems' structure as well as dynamic changes thereof upon exposure to the release medium. Dexamethasone particles were initially homogeneously distributed throughout the systems. The hydrophobicity of the matrix former very much limits the amounts of water penetrating into the system, resulting in only partial drug dissolution. The mobile drug molecules diffuse out into the surrounding environment, due to concentration gradients. Interestingly, Raman imaging revealed that even very thin silicone layers (<20 mu m) can effectively trap the drug for prolonged periods of time. The physical state of the drug (amorphous, crystalline) did not affect the resulting drug release kinetics to a noteworthy extent.
Amorphous riboflavin (free base) could be produced for the first time via high energy ball milling of a commercial crystalline form (Form I). Importantly, this solid state amorphization process allowed to circumvent chemical degradation occurring during melting as well as the lack of suitable solvents, which are required for amorphization via spray- or freeze-drying. The amorphous state of riboflavin was thoroughly characterized, revealing a complex recrystallization pattern upon heating, involving two enantiotropic polymorphic forms (II and III) and a dihydrate. The glass transition temperature (Tg) and heat capacity (Cp) jump of the amorphous form were determined as 144 °C and 0.68 J/g/°C. Moreover, the relative physical stability of the different physical states has been elucidated, e.g., at room temperature: I > II > III. The following rank order was observed for the dissolution rates in water at 37 °C during the first 4 h: amorphous > III ≈ II > I. Afterwards, a dihydrate crystallized from the solutions of amorphous and metastable crystalline riboflavin forms, the solubility of which was well above the solubility of the stable FormI.
The aim of this study was to better understand the impact of the chemistry of poly(lactic-co-glycolic acid) (PLGA) polymers on the resulting drug release kinetics from implants prepared by melting and molding. Dexamethasone was incorporated as the drug. The polymer molecular weight of the PLGA, lactic acid:glycolic acid ratio and type of end groups (ester versus free acid) were varied. The implants were characterized using optical macroscopy, SEM, X-ray powder diffraction, DSC, gravimetric monitoring of dynamic changes in the systems' dry and wet mass upon exposure to the release medium as well as drug release and pH measurements. Interestingly, the shape of the drug release profiles was similar in all cases: No noteworthy burst effect was observed. Dexamethasone release set on after a lag time, the length of which strongly depended on the PLGA chemistry: The lag time decreased with decreasing polymer molecular weight, increasing glycolic acid content and was shorter for -COOH end groups compared to ester end groups. In all cases, drug release set on as soon as a critical hydrophilicity and polymer molecular weight were reached and substantial system swelling started: The penetration of large amounts of water into the implants allowed for complete dexamethasone dissolution and relatively rapid diffusion of the dissolved drug molecules through a highly swollen PLGA gel up to 100% drug release.
Several formulation strategies have been proposed for oral colon delivery, particularly for the therapy of inflammatory bowel disease (IBD). However, targeting the large intestine remains a challenging goal. The aim of this study was to develop and evaluate a novel type of drug delivery system, which is based on multiple drug release triggers for reliable performance. The system consists of: (i) a drug core, (ii) an inner swellable low-viscosity hydroxypropyl methylcellulose (HPMC) layer, and (iii) an outer film coating based on a Eudragit® S:high-methoxyl (HM) pectin (7:3 w/w) blend, optionally containing chitosan. Convex immediate release tablets (2 or 4 mm in diameter) containing paracetamol or 5-aminosalicylic acid (5-ASA) were coated in a fluid bed. The double-coated tablets exhibited pulsatile release profiles when changing the release medium from 0.1 N HCl to phosphate buffer pH 7.4. Also, drug release was faster in simulated colonic fluid (SCF) in the presence of fecal bacteria from IBD patients compared to control culture medium from tablets with outer Eudragit® S: HM pectin: chitosan coatings. The latter systems showed promising results in the control of the progression of colitis and alteration of the microbiota in a preliminary rat study.
This study aimed to evaluate and better understand the potential impact that a layer of surrounding hydrogel (mimicking living tissue) can have on the drug release from PLGA microparticles. Ibuprofen-loaded microparticles were prepared with an emulsion solvent extraction/evaporation method. The drug loading was about 48%. The surface of the microparticles appeared initially smooth and non-porous. In contrast, the internal microstructure of the particles exhibited a continuous network of tiny pores. Ibuprofen release from single microparticles was measured into agarose gels and well-agitated phosphate buffer pH 7.4. Optical microscopy, scanning electron microscopy, differential scanning calorimetry, X-ray powder diffraction, and X-ray μCT imaging were used to characterize the microparticles before and after exposure to the release media. Importantly, ibuprofen release was much slower in the presence of a surrounding agarose gel, e.g., the complete release took two weeks vs. a few days in well agitated phosphate buffer. This can probably be attributed to the fact that the hydrogel sterically hinders substantial system swelling and, thus, slows down the related increase in drug mobility. In addition, in this particular case, the convective flow in agitated bulk fluid likely damages the thin PLGA layer at the microparticles' surface, giving the outer aqueous phase more rapid access to the inner continuous pore network: Upon contact with water, the drug dissolves and rapidly diffuses out through a continuous network of water-filled channels. Without direct surface access, most of the drug “has to wait” for the onset of substantial system swelling to be released.
The effect of probiotics in improving or maintaining oral health in orthodontic patients is understudied. The aim of this study is to evaluate the effect of probiotic administration in addition to tooth brushing on clinical gingival inflammation, plaque formation, subgingival microbiota composition, and salivary biomarkers of inflammation in adolescents with fixed orthodontic appliances. The present study is a 6-month, double-blind, two-arm, placebo-controlled, single-center trial, in which 116 adolescent volunteers aged 12–16 years will be recruited from the patients of the orthodontics clinic of the University Hospital of Lille, France. Subjects who meet the eligibility criteria will be allocated to one of the following groups: (i) control: two placebo lozenges per day for 90 days together with regular oral hygiene, (ii) test: two probiotic lozenges per day for 90 days together with regular oral hygiene. Clinical assessment and biological sample collection will be performed at baseline, 3 and 6 months. In addition, compliance outcomes and adverse events will be monitored.
Targeted drug delivery to the colon offers a myriad of benefits, including treatment of local diseases, direct access to unique therapeutic targets and the potential for increasing systemic drug bioavailability and efficacy. Although a range of traditional colonic delivery technologies are available, these systems exhibit inconsistent drug release due to physiological variability between and within individuals, which may be further exacerbated by underlying disease states. In recent years, significant translational and commercial advances have been made with the introduction of new technologies that incorporate independent multi-stimuli release mechanisms (pH and/or microbiota-dependent release). Harnessing these advanced technologies offers new possibilities for drug delivery via the colon, including the delivery of biopharmaceuticals, vaccines, nutrients, and microbiome therapeutics for the treatment of both local and systemic diseases. This review details the latest advances in colonic drug delivery, with an emphasis on emerging therapeutic opportunities and clinical technology translation.